Standard Installation
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY
TO PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT!
WARNING - To reduce the risk of
FIRE OR INJURY TO PERSONS:
Turn
off/unplug
and
allow
replacing lamp/LED. Fixture gets HOT quickly!
Contact only switch/plug when turning on.
Do not touch hot lens, guard, or enclosure.
Keep fixture away from materials that may burn.
Do not operate the luminaire fitting with a missing or
damaged shield. Do not touch the source at any time.
Use a soft cloth or gloves. Oil from skin may cause
damage.
SAVE THESE INSTRUCTIONS
Proper soil preparation is recommended before installation. See the DIG-IT guide at
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL
ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
Flammable
Warning
High Voltage
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local and
Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective
to
cool
before
equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and
lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause an
unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
www.bklighting.com/collaterals/install/digit.pdf for more information.
Faceplate
Body
18/3 Ga. Wire
Hot Surface
SAFETY AND INSTALLATION INSTRUCTIONS
· Suitable for wet locations
Surface Mount Collar
PVC Housing
INSTRUCTIONS
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
TOOLS
5/64", 9/64" & .050" Allen Wrench
NEEDED:
Waterproof Wire Connectors
Silicone
• Do not block light emanating from product in whole or part, as
this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body.
• Replace LED assembly only with correct wattage and type of
power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
Surface mount uplights are intended for installation in
wood, pavers, stone, and other hardscapes.
Not recommended for concrete pour
RELEASE DATE
06/26/2023
DENALI
UPLIGHT - INTEGRAL
INSTALLATION
installations.
REFERENCE NUMBER
INS-2826-00

Advertisement

loading
Need help?

Need help?

Do you have a question about the DENALI and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for B-K lighting DENALI

  • Page 1 • info@bklighting.com THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
  • Page 2 DENALI UPLIGHT - INTEGRAL Standard Installation 5-1/2” O.D. 5” O.D. Drill 5” diameter hole into mounting surface at 2. Loop minimum of 6” of wiring inside housing to 3. Place housing into hole. Surface mount collar uplight installation location as per lighting plan.
  • Page 3 DENALI UPLIGHT - INTEGRAL Standard Installation In-ground Installation Instructions Soil Prep Excavated for Housing Conduit trench Conduit Trench A. Determine Soil Type by referencing DIG-IT Guide. B. Dig hole 15” wide and 12” deep. C. Prep soil according to DIG-IT Guide.
  • Page 4 DENALI UPLIGHT - INTEGRAL Standard Installation In-ground installation instructions LINE LINE Wire nuts must 6” FIXTURE clear opening GROUND GROUND min. Finished grade 8. Remove temporary cover and pull out primary 120V, 9. Access primary 120V, branch circuit wiring inside WIRING DIAGRAM branch circuit wiring.
  • Page 5 DENALI UPLIGHT - INTEGRAL Standard Installation This product is available with field replaceable components. Exclusive interchangeable OPTIKITS and modular LED components with quick disconnects simplifies upgrades and maintenance when necessary. Fixture Re-lamping Remove faceplate from collar using (2) #8-32 2. Remove fixture from collar.
  • Page 6 DENALI UPLIGHT - INTEGRAL Standard Installation This product is available with field replaceable components. Exclusive interchangeable OPTIKITS and modular LED components with quick disconnects simplifies upgrades and maintenance when necessary. 12. Twist to reinstall optic onto optic holder. 13. Tighten three (3) #8-32 set screws with a 5/64”...