Download Print this page
WT sensor PCRL02 Quick Start Manual

WT sensor PCRL02 Quick Start Manual

Radar level meter

Advertisement

Quick Links

PCRL04,PCRL05,PCRL06,PCRL07,PCRL09,PCRL010,
Features
Small antenna size, easy to install;
Non-contact radar, no wear, no pollution.
Almost no corrosion, bubble effect; almost
not affected by water vapor in the
atmosphere, the temperature and
pressure changes.
Serious dust environment on the high
level meter work has little effect.
A shorter wavelength, the reflection of solid
surface inclination is better.
Beam angle is small, the energy is
concentrated, can enhance the ability of
echo and to avoid interference.
The measuring range is smaller, for a
measurement will yield good results.
High signal-to-noise ratio, the level
fluctuation state can obtain better
performance.
High frequency, measurement of solid
and low dielectric constant of the best
choice.
Notes:
1 Do not touch the diaphragm with hard
objects, which may cause damage to the
diaphragm.
2 Please read the Instruction Manual of
the product carefully before installation
and check the relevant information of the
product.
3 Strictly follow the wiring method for
wiring, otherwise it may cause product
damage or other potential faults.
4 Misuse of the product may cause danger
or personal injury.
April 2023
PCRL02,
PCRL011 Radar level meter
Product overview
frequency radar sensor, the maximum measurement range can
reach up to 60 meters. Antenna is optimized further processing,
the new fast microprocessors have higher speed and efficiency
can be done signal analysis, the instrumentation can be used
for reactor, solid silo and very complex measurement
environment.
Notes:
1 Do not misuse documentation.
2 The information presented in this product sheet is for reference
only. Do not use this document as a product installation guide.
3 Complete installation, operation, and maintenance information is
provided in the instructions of the product.
4 Misuse of the product may cause danger or personal injury.
1
This series of radar level meter adopted 26G high
www.wtsensor.com

Advertisement

loading

Summary of Contents for WT sensor PCRL02

  • Page 1 PCRL02, PCRL04,PCRL05,PCRL06,PCRL07,PCRL09,PCRL010, PCRL011 Radar level meter Features ■ Small antenna size, easy to install; Non-contact radar, no wear, no pollution. ■ Almost no corrosion, bubble effect; almost not affected by water vapor in the atmosphere, the temperature and pressure changes.
  • Page 2 Principle Radar level transmitter antenna microwave pulse is narrow, the downward transmission antenna. Microwave exposure to the medium surface is reflected back again by the antenna system receives, sends the signal to the electronic circuit automatically converted into level signals (because the microwave propagation speed, electromagnetic wave to reach the target and the reflected back to the receiver this time is almost instantaneous).
  • Page 3 Product Introduction in mm For liquid PCRL02 Application:Slightly corrosive liquid Measuring Range:10 meters Process Connection:Thread, flange Medium Temperature:-40℃ ~ 130℃ Process Pressure:-0.1 ~ 0.3MPa Accuracy:± 5mm Protection Grade:IP67 Frequency Range:26GHz Signal Output:4... 20mA/HART (Two-wire / Four) RS485/ Modbus PCRL04 Application:Slightly corrosive liquid, volatile liquid tank Measuring Range:20 meters...
  • Page 4 Application:Hygienic liquid storage tank, highly corrosive PCRL09 tank Measuring Range:20 meters Process Connection:Flange Medium Temperature: -40℃ ~ 130℃(Standard), -40℃ ~ 200℃(High temp type) Process Pressure:-0.1 ~ 4MPa Accuracy:± 3mm Protection Grade:IP67 Frequency Range:26GHz Signal Output:4... 20mA/HART (Two-wire / Four) RS485/ Modbus PCRL10 Application:Rivers, lakes, shoals Measuring Range:30 meters...
  • Page 5 PCRL11 Application:Rivers, lakes, shoals Measuring Range:70 meters Process Connection:Thread, flange Medium Temperature: -40℃ ~ 100℃ Process Pressure:Natural pressure Accuracy:± 10mm Protection Grade:IP65/ IP67 Frequency Range:26GHz Signal Output:4... 20mA/HART (Two-wire / Four) RS485/ Modbus For powder, granules, lumps Application:powder, granules, lumps PCRL05 Measuring Range:...
  • Page 6 PCRL06 Application:powder, granules, lumps Measuring Range: 196mm :powder 35 meters, granules 40 meters, lumps 40 meters; 246mm :powder 45 meters, granules 50 meters, lumps 50 meters; Process Connection:Thread, universal flange Medium Temperature: -40℃ ~ 130℃(Standard), -40℃ ~ 200℃(High temp type) Process Pressure:-0.1 ~ 0.3MPa Accuracy:±...
  • Page 7 Installation Requirements Installation guide: Be installed in the diameter of the 1/4 or 1/6. Note: The minimum distance from the tank wall should be 200mm. Note: ① Datum ② The container center or axis of symmetry The top conical tank level, can be installed at the top of the tank is intermediate, can guarantee the measurement to the conical bottom.
  • Page 8 The instrument cannot be installed in the arched or domed roof intermediate. In addition to produce indirect echo is also affected by the echoes. Multiple echo can be larger than the real value of signal echo, because through the top can concentrate multiple echo. So cannot be installed in a central location.
  • Page 9 Electrical Connection The power supply voltage: (4~20)mA/HART (Two wire system) The power supply and the output current signal sharing a two core shield cable. The supply voltage range see technical data. For intrinsically safe type must be a safety barrier between the power supply and the instrument.
  • Page 10: Safety Instructions

    24V RS485/Modbus wiring diagram as follows: Safety instructions: Please observe the local electrical code requirements! Please comply with local requirements for personnel health and safety regulations. All electrical components of instrument operation must be completed by the formal training of professionals.
  • Page 11 Tighten the cable seal head, see the ② Please electrical interface will not use blind plug tight, see the ③ Instrument Commissioning There are three kinds of debugging method: Display / Keyboard Host debugging HART handheld programmer Display / Keyboard: Please debug the instrumentation by four buttons on the display screen.
  • Page 12 The outer shell: SUP-RD901 SUP-RD902T April 2023 www.wtsensor.com...
  • Page 13 SUP-RD908/909 SUP-RD903 SUP-RD904 April 2023 www.wtsensor.com...
  • Page 14 SUP-RD905 Flange type: April 2023 www.wtsensor.com...
  • Page 15 Technical Parameters The outer shell The seal between the shell and the shell cover Silicone rubber Casing window Polycarbonate The ground terminal Stainless steel The power supply voltage Two wire system The standard type (16 ~ 26) V DC Intrinsically safe (21.6 ~ 26.4) V DC Power dissipation max 22.5mA / 1W...
  • Page 16 Seismic Mechanical vibration l0m/s², (10 ~ 150) Hz Meter Linearity Emission angle Depending on the size of the antenna -¢76mm 12° -¢96mm 8° -¢121mm 6° Precision See chart Wotian reserves the right to make any change in this publication without notice. The information provided is believed to be accurate and reliable as of this product sheet.

This manual is also suitable for:

Pcrl04Pcrl05Pcrl06Pcrl07Pcrl09Pcrl010 ... Show all