Connecting Indoor Unit Wiring
WARNING
• Verify that main power to the unit is completely off before proceeding with these steps as there is a risk of electrical shock, bodily injury, and /
or death.
shock, bodily injury, and / or death.
• Follow all safety and warning information outlined at the beginning and throughout this manual. Failure to do so will cause electrical shock,
bodily injury, and / or death.
• Follow all safety and warning information outlined at the beginning and throughout this manual. Failure to do so will cause unit failure.
• Connect the communication / connection (power) cable to the indoor unit by matching the terminals on the outdoor unit control board. Verify
the color of the wires at the outdoor unit, along with the terminal numbers, match those for the indoor unit.
• Images are representative; actual appearance will vary.
• Refer to the circuit diagram on the indoor unit.
1. Using a Phillips head screwdriver, remove the
metal control box cover (one panel) by unscrew-
ing the two (2) screws that hold it in place. Set
aside the metal control box cover and screws for
reattachment.
2. Insert the communication / connection (power)
cable (from the outdoor unit to the indoor unit)
through the designated access hole in the side of
the ducted frame (see images). If using a conduit,
attach it to the conduit hole, and secure with a lock
nut.
3. Attach the communication / connection (power)
cable to the inside of the frame with the clamp.
4. Using a JIS screwdriver, connect the cable termi-
nals to the terminal block. Ensure wire color and
terminal number of the indoor unit matches those
of the outdoor unit. Refer to the wiring diagram on
the indoor unit.
5. When installing the wired remote controller (sold
separately), insert the controller wiring through its
designated access hole below the communication
/ connection (power) cable. Refer to the wiring
diagram on the indoor unit. Using a JIS screwdriver, attached that cable to the appropriate
terminal block connection.
6. Reinstall the metal control box by reattaching it with its two (2) screws.
• Each wire must be securely attached to the terminal block.
• Ground cable must be longer than the other wires.
• Secure the cable onto the control board using a cable tie.
• Use a conduit to protect the cable / refrigerant piping from the indoor unit to the outdoor unit. For more information on conduits or the bun-
dling method, see the Refrigerant Piping Connection section.
ELECTRICAL SYSTEM INSTALLATION
Figure 73: Removing the Control Box.
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.

Indoor Unit Electrical Connections

Figure 74: Location of the Access Holes.
Communications / Connection (Power) Cable
Figure 75: Using a Conduit.
Remote Controller Cable
Conduit Hole
Mid-Static
IDU Frame
Lock Nut
Conduit
55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lh188hv1Lh128hv1Lh248hv1

Table of Contents