1. Water pump air bleed bolt
15. When coolant begins to flow out of the bolt
hole, tighten the water pump air bleed bolt to
the specified torque.
Tightening torque:
Water pump air bleed bolt:
10 Nm (1.0 m·kgf, 7.2 ft·lbf)
16. Remove panel E. (See page 8-10.)
17. Loosen the clamp screw, and then remove
the V-belt cooling duct.
1
1. V-belt cooling duct
2. Clamp screw
18. Loosen the cylinder head air bleed bolt, with-
out removing it, to allow all of the air to es-
cape from the air bleed bolt hole.
8-36