en Installation instructions
WARNING ‒ Risk of electric shock!
It must always be possible to disconnect the appliance
from the electricity supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed.
The mains plug for the mains power cable must be
easily accessible after the appliance is installed.
If this is not possible, an all-pole isolating switch
must be integrated into the permanent electrical in-
stallation according to the conditions of overvoltage
category III and according to the installation regula-
tions.
The permanent electrical installation must only be
wired by a professional electrician. We recommend
installing a residual-current circuit breaker (RCCB)
in the appliance's power supply circuit.
Sharp-edged components inside the appliance may
damage the connecting cable.
Do not kink or trap the connecting cable.
¡ The connection data can be found on the rating
plate. → Page 12
¡ The connecting cable is approx. 1.30 m long.
¡ This appliance complies with the EC interference
suppression regulations.
¡ The appliance corresponds to protection class 1.
You should therefore only use the appliance with a
protective earth connection.
¡ Do not connect the appliance to the power supply
during installation.
¡ Ensure that the protection against contact is guaran-
teed during installation.
19.8 Information on the installation situation
¡ Install this appliance on the kitchen wall.
¡ The appliance must be installed before the upper
cabinets, if these are deeper than 370 mm.
¡ To install additional special accessory parts, ob-
serve the enclosed installation instructions.
¡ The appliance must be installed with no more than
one side directly next to a tall unit, an upper cabinet
or a wall. The distance between the appliance and
the tall cabinet, upper cabinet or the wall must be at
least 50 mm.
¡ The width of the extractor hood must correspond at
least with the width of the hob.
¡ To optimally detect the cooking vapours, install the
appliance in the middle of the hob.
19.9 Installation
Checking the wall
Check whether the wall is horizontal and adequately
1.
load-bearing.
The maximum weight of the appliance is 30 kg.
Drill the hole depth in accordance with the length of
2.
the screws.
Use the enclosed screws and wall plugs.
3.
The enclosed screws and wall plugs are suitable for
use with solid brickwork. Use suitable fixing material
for other structures, e.g. plasterboard, porous con-
crete, poroton bricks.
16
Install the appliance with a fixing material which is
4.
sufficiently stable and has been adjusted accord-
ingly for both the structural conditions and the
weight of the appliance.
Check the cut-out area for existing cables of other
5.
appliances.
Preparing the wall
Observe the information on the installation situation.
1.
→ Page 16
Ensure that there are no electrical wires, gas pipes
2.
or water pipes in the area where holes are to be
drilled.
Cover the hob to prevent damage.
3.
Determine the position of the extractor hood and
4.
lightly mark where the lower edge of the appliance
should be on the wall.
Determine the centre of the hob.
Comply with the safety clearances for the hob.
We recommend fitting the extractor hood in such a
way that the lower edge of the glass screen is in
line with the lower edges of the adjacent wall-hung
cabinets.
To make the installation easier, apply and secure
5.
the packaging section that is used as the template
to the line that is marked out.
Mark the positions for the screws.
6.
Drill the 8 mm diameter holes to a depth of 80 mm
7.
for the fastenings.
Remove the template.
8.
Installing the appliance bracket
Screw on the appliance bracket for the extractor
1.
hood hand-tight.