Rebuilding RAID 1 volumes

If the status of a RAID 1 volume is Failed or Degraded, you can rebuild it through the Intel RST configuration
utility. To rebuild a RAID 1 volume, ensure that at least one member drive of the RAID 1 volume works
correctly. Replace the failed drive with a new one that has the same capacity before you rebuild a RAID 1
volume.
To rebuild a RAID 1 volume, do the following:
1. Enter the Intel RST configuration utility. See "Entering the Intel RST configuration utility" on page 42.
2. Press the up and down arrow keys to select the volume that you want to rebuild under RAID Volumes.
Press Enter to open the RAID VOLUME INFO window.
3. Select Rebuild and press Enter to open the Rebuild Volume window.
4. Select the drive that you want to rebuild and press Enter to initiate the rebuild process.
After you initiate the rebuild process, the Intel (R) Rapid Storage Technology window is displayed. The
RAID 1 volume under rebuilding is displayed under RAID Volumes with a Rebuilding mark.
5. Wait a few minutes. When the rebuild process finishes successfully, the Rebuilding mark is changed to
the Normal mark.
6. Press F10 to save changes and exit.