After the RAID volume is created, the Intel (R) Rapid Storage Technology window is displayed, and
the created volume is displayed under RAID Volumes.
4. Press F10 to save changes and exit.

Delete RAID volumes

Attention: All the existing data stored on the selected drives will be erased after you delete RAID volumes.
1. Enter the Intel RST configuration utility.
2. Select the volume that you want to delete under RAID Volumes. Press Enter to open the RAID VOLUME
INFO window.
3. Select Delete and press Enter to delete it from the RAID Volumes list.
4. When prompted, select Yes to confirm the deletion of the selected RAID volume.
After you delete the RAID volume, the Intel (R) Rapid Storage Technology window is displayed. Member
drives of the deleted volume are displayed under Non-RAID Physical Disks.
5. Press F10 to save changes and exit.

Reset storage drives to non-RAID

Attention: All the existing data stored on the selected drive will be erased after you reset it to non-RAID.
1. Enter the Intel RST configuration utility.
2. Select the volume that you want to reset under RAID Volumes. Press Enter to open the RAID VOLUME
INFO window.
3. Select the drive that you want to reset under RAID Member Disks. Press Enter to open the PHYSICAL
DISK INFO window.
4. Select Reset to Non-RAID and press Enter. When prompted, select Yes to confirm the reset action.
After the reset process finishes, the Intel (R) Rapid Storage Technology window is displayed. The reset
drive is listed under Non-RAID Physical Disks, and the volume of the reset drive is still listed under
RAID Volumes. However, the status is changed from Normal to Failed or Degraded.
5. Press F10 to save changes and exit.

Rebuild RAID 1 volumes

If the status of a RAID 1 volume is Failed or Degraded, you can rebuild it through the Intel RST configuration
utility. To rebuild a RAID 1 volume, ensure that at least one member drive of the RAID 1 volume works
correctly. Replace the failed storage drive with a new one that has the same capacity before you rebuild a
RAID 1 volume.
1. Enter the Intel RST configuration utility.
2. Select the volume that you want to rebuild under RAID Volumes. Press Enter to open the RAID
VOLUME INFO window.
3. Select Rebuild and press Enter to open the Rebuild Volume window.
4. Select the drive that you want to rebuild and press Enter to initiate the rebuild process.
After you initiate the rebuild process, the Intel (R) Rapid Storage Technology window is displayed. The
RAID 1 volume under rebuilding is displayed under RAID Volumes with a Rebuilding mark.
5. Wait a few minutes. When the rebuild process finishes successfully, the Rebuilding mark is changed to
the Normal mark.
6. Press F10 to save changes and exit.
.