FOCUS OR FLANGE-BACK ADJUSTMENT
PRECAUTION OF FLICKER
When the camera is aimed at objects which are illumi-
The following adjustment should be made by quali-
nated by fluorescent lamp, picture may have flicker.
fied service personnel or system installers.
1.
Loosen
the screw
on the Flange-back
Adjusting
Ring.
C-mount
Flange-back
CS-mount lens
lens
adjusting ring
Focus adjust for
CS mount lens
Focus adjust for
C-mount lens
2.
Turn the Flange-back Adjusting Ring to the desired
position.
CAUTION:
Do not turn this ring counterclockwise too much
as this could damage the inner glass and CCD
image sensor.
3.
Tighten the screw
on the Flange-back Adjusting
Ring.
oe oe