Yaesu FT-101E Instruction Manual page 25

Hide thumbs Also See for FT-101E:
Table of Contents

Advertisement

There
is a littl difference
in the
wile current
between
AC
and
BC
operation,
Adjust
the idle eurrent
to 60
my
for each operation,
11.
POWER
OUTPUT
METER
ADJUSTMENT
VR.
located
on
the transceiver
rear
panel
adjacent
to the antenna
coax
fitting, provides
an adjustment
for
power output
indication
on the meter.
This potentiometer
should
be adjusted
to indicate
1/2
to 2/4. full seale meter
deflection
when
the transmitter
ig producing
full output
power in the tune
position.
it should
be
noted
that
the
meter
indicates relative
power
output
and
is not
the
basis
for determining
actual
power
output,
VR6
has been
preset
at the factory
to read 1/2 to
2/3 full seale into a 52 ohm dummy load. The operator
Should not indiscriminately adjust VRG into an unknown
load or an antenna
with high
VSWR.
12.
FINAL AMPLIFIER
NEUTRALIZATION
When
replacing the final amplifier tubes,
it may
be
necessary to resel the bias to give correct idle current
and check
neutralization,
Using the procedure
outline
below
will guarantee
maximum
output and long tube
life
CAUTION
HIGH VOLTAGES
ARE PRESENT
ON UNDER
SIDE
OF
CHASSIS
AND
INSIDE
OF
FINAL
COMPARTMENT.
USE
GREAT
CARE
WHILE
MAKING
ADIUSTMENTS
WITH
WIRING
EX
POSED,
dees
ti
FINAL
AMPLIFIER
COMPARTMENT
(1) Connect a dummy
load to antenna,
and set. meter
to TC,
(2) Locate TC27
the neutralization variable
capacitor
the
the
the
driver stage band switch wafer, in the final ampli.
shaft
on
underside
of
chassis.
near
fier section,
(3) Check final amplifier idle current in USB or LSB
position and adjust as described
before.
200m A,
) Rotate
PLATE
tuning centro)
and observe dip as
Indicated on the meter.
othe dip is not prominent,
reduce the loadme
control shehtly
for better indi.
cation.
As the PLATE
control is rotated the meter
(6) Determine
which
side of the dip. rises abruptly
set
PLATE
control
slightly
to this side of dip
keeping the meter
reading below
LOO) mA,
=J
Repeat
steps
6 and
7 until
the meter
indicates a
smooth
and equal rise on either side of the maxi
mum
dip point.
The final compartment cover must be in place to supply