Download Print this page

NPC ReverseTap RD BF1 Installation Manual page 4

In-counter kegerator system

Advertisement

ReverseTap In-counter Models Installation Guide ( Kegerator )
6. Connect the power and run a function test.
- ① ReverseTap power turns ON as soon as power is connected.
- ② To individually turn ON/OFF each unit, press START/STOP button in its keypad for a few seconds.
- ③ Check if a cup is easily inserted and properly sensed.
- ④ Check if LED is lit properly.
- ⑤ Check if solenoid valves are opened with clicking sound.
- ⑥ Check if all buttons in each key pad work properly. ( the sensitivity of each button may slightly differ )
* Assemble PROTECT COVER and NOZZLE COVER.
* Press START/STOP button in its keypad for a few
seconds to turn ON/OFF units individually.
7. Tightly fasten main body of ReverseTap with the included Bracket set to the desired surface.
① Assemble bolts(M4 X 100mm) with wing nuts.
② Locate fastening clamps beneath the kegerator and fasten the bottom part of the dispenser with bolt-wing nut
assemblies. ( Total of 4 ea of fastening clamps are included in the product )
③ Fasten wing nuts to tightly fix ReverseTap to the kegerator with fastening clamps.
( Loosened wing nuts may cause cold air escape and foreign substances flow in )
* Check the number of bracket sets and assemble bolts with wing
nuts.
③~⑥
* Insert a cup to check LED, Solenoid valve functions correctly, and check all buttons work fine.
* Bracket set and bolts fastening spots
V2.0