Download Print this page

NPC ReverseTap RD-B1 Installation Manual page 3

Countertop kegerator system

Advertisement

ReverseTap Countertop Models Installation Guide ( Kegerator )
3. Connect DC 24 V CONNECTOR CABLE with the main power cable of ReverseTap.
- The end part of DC 24 V CONNECTOR CABLE is a waterproof connector.
- DC plug of DC 24 V CONNECTOR CABLE is not waterproof, therefore keep it away from water and tape
around the joint part.
- 5~8 units of SF-Series use two adaptors, so it must be used with two DC 24 V CONNECTOR CABLE as well.
*DC 24 V CONNECTOR CABLE
* Parts without waterproof capability in DC 24 V CONNECTOR
CABLE must be kept away from water and joints must be
taped around to prevent it from getting wet.
4. Connect the power and run a function test.
- ① ReverseTap power turns ON as soon as power is connected.
- ② To individually turn ON/OFF each unit, press START/STOP button in its keypad for a few seconds.
- ③ Check if a cup is easily inserted and properly sensed.
- ④ Check if LED is lit properly.
- ⑤ Check if solenoid valves are opened with a knocking sound.
- ⑥ Check if all buttons in each key pad work properly. ( the sensitivity of each button may slightly differ )
* Press START/STOP button in its keypad for a few seconds to turn ON/OFF units individually.
* Organize the cables after connecting DC 24 V CONNECTOR CABLE with ReverseTap.
V2.0

Advertisement

loading

This manual is also suitable for:

Reversetap rd-bl2Reversetap rd s1Reversetap rd s2Reversetap rd-sl2Reversetap rd s3Reversetap rd s4