  • Page 2 Technology Co.,Ltd Address: No. 27-201, Zhongwu 3rd Road, Zhongwu Community, Hangcheng Street, Bao’an District, Shenzhen City, Guangdong Province.CHINA. 518100 Customer Service: support@belifu.com Please download the PDF manual on the below link: https://belifu.com/downloads/ Precaution ·Please read the instructions manual carefully before using the device.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS 1. INTRODUCTION 2. SAFETY INTRODUCTIONS 3. FUNCTIONS OF THE DEVICE 4. OPERATING INSTRUCTIONS 5. BATTERY AND MEMORY FUNCTION 6. MAINTENANCE 7. MODE INSTRUCTION 8. TENS EMS ELECTRODE PLACEMENT GUIDE 9. TROUBLESHOOTING 10. PRODUCT DESCRIPTIONS 11. MEDICAL DISCLAIMER 12.
  • Page 4: Introduction

    1.INTRODUCTION Working principle It acts on the human body through the electricity pulse wave, the electric energy is sucked by the human body and the energy form is changed, which causes a series of physical and chemical changes, produces local or systemic physiological reactions, and finally affects the pathological process and plays a corresponding role.
  • Page 5 However, it should not be used by children, pregnant women, or anyone who has an implanted metallic or electronic device. Ask your physician if you have any questions. Package contents Items Quantity Device 1 pc Manual 1 pc lead wires with 2 2 pcs connectors (2.5mm) large self-adhesive...
  • Page 6: Safety Introductions

    2.SAFETY INTRODUCTIONS Warnings (DO NOT USE THIS UNIT UNDER BELOW CONDITIONS:) implanted electronic medical device such as a pacemaker. electrode medical devices used for monitoring health functions. humidity such as a bathroom. because the device has not been evaluated for pediatric use. physician at once if you feel pain discomfort such as dizziness or nausea.
  • Page 7 electronic monitoring equipment (e.g., cardiac monitors, ECG alarms), which may not operate properly when the electrical stimulation device is in use. thoughts or intentions. physician if your pain does not improve, becomes more than mild, or continues for more than five days. or rashes, or over swollen, red, infected, or inflamed areas or skin eruptions (e.g., phlebitis, thrombophlebitis, varicose veins).
  • Page 8 stimulator. When connected to a patient, burns may occur at the stimulator electrode and may damage the stimulator. feeling abnormal. abnormalities in the brain. exceeds 38℃ . Notice Caution should be used in the presence of the following: away from children. warning items.
  • Page 9 thorax may increase the risk of cardiac fibrillation patients, or suffer from emotional distress, dementia, and low IQ people. improper use may lead to danger. pain symptoms, consult a doctor for diagnosis before use. head and pubic area. cancer or other health-threatening conditions should consult a doctor before using this device.
  • Page 10 each use. removing the electrode pad. electrode wires and electrodes recommended by manufacturers. Consult your doctor before using the device especially in the following cases: suspected or suffering from hypertension, thrombosis or malignant mass. (e. g. metabolic disorders) with reduced pain.
  • Page 11 Explanation of figures. symbols, warning statements and abbreviations on the equipment Meanings of symbols used for marking described in instructions for use Caution! Type BF applied part Direct current Protected against solid foreign IP22 vertically falling water drops when ENCLOSURE tilted up to 15°...
  • Page 12: Functions Of The Device

    3.FUNCTIONS OF THE DEVICE 1 Time indicator 2 LCD screen 3 A/B channel intensity indicator 4 Pause indicator 5 A/B output 6 Battery indicator 7 Charging port 8 Mode selection button 9 Intensity adjust button 10 Turn on/off (Long Press) & Pause button (Short Press) 11 Time button (Short Press) &...
  • Page 13: Operating Instructions

    4.OPERATING INSTRUCTIONS BEFORE USING YOUR DEVICE 1.Please check if there are any damages to the device, electrode leads, or electrode pads. 2.Please ensure the electrode leads connection is not broken. 3.Please ensure that the device is fully charging. 4.When the device is in no-output status, it will automatically shut down if there is no further action within 5 minutes.
  • Page 14 HOW TO USE Connecting electrodes pads to STEP 1: electrode wire. (IMG.1) Note: Please check the snap connections to ensure they are fastened. Use at least one pair of pads, one pad can’t work alone. IMG.1 Paste electrode pads to the area STEP 2: where you want therapy.
  • Page 15 IMG.2 Connecting electrodes wire to STEP 3: the device (channel A/B). (IMG.3) IMG.3 Long Press the upper-right STEP 4: “Power/Pause” button to turn on device(PS: Short Press is for the pause function)(IMG.4) IMG.4 Press “A”/ “B” button to choose STEP 5: A or B channel mode.
  • Page 16 Please check the flash channel indicator on the screen to make sure it is the channel you want to use. The flash "A" icon indicates you Channel A. If you choose Channel B, the Channel B icon will flash to indicate the Channel B is working.
  • Page 17 IMG.6 Short press upper-left button “+” STEP 7: “-” button to adjust A/B intensity) (IMAG.7) IMG.7 Short press upper right-side STEP 8: Time/Lock button to set the time (PS: Long Press is for the lock function)(IMG.8) The default time is 20mins. Short Press the “Power/Time”...
  • Page 18 be increased by 10mins. When it’s increased up to 80mins, continue to press the “T” button to jump to 10mins. IMG.8 Long Press the Time/Lock button STEP 9: to lock the unit after you complete the above settings (PS: Short Press is for time setting)(IMG.9) IMG.9 Long Press the Power/Pause...
  • Page 19: Battery And Memory Function

    IMG.10 Remove the pads from your skin STEP 11: and store the products Remove the pads from you skin gently, and paste the plastic dust-proof film on them, take them off the electrode wires and unplug the wires, put them and the device into the storage bag.
  • Page 20: Maintenance

    ·Charging the battery 1.The device is powered by an internal, rechargeable lithium battery that can be charged through a standard wall outlet or through the USB port of a computer or power bank. Signs the device needs to be charged include dimness of the screen or failure to display the screen, and weak sensations from the electrodes.
  • Page 21 The gel surface of the massage pad should be kept clean and avoid dirt like dust, oily substances, sticky substances, etc., otherwise the stickiness will be decreased. Please put the massage pads back to the pad holders or paste the protective films back onto the pads after use.
  • Page 22 Safekeeping Please do not put the main machine in the place exposed to sunlight, high temperature, humidity, lots of dust, or the place close to fire, easy to vibrate or shock.Please put where children can't reach it. Cleaning and storing pad Clean: After using pads on your body, please drop a little clean water on the sticky side and use fingertips to clean it softly...
  • Page 23 WARM TIPS FOR SKINCARE To avoid skin irritation, especially if you have sensitive skin, follow these suggestions: 1. Wash the area of skin where you will be placing the electrodes, using mild soap and water before applying electrodes, and after taking them off. Be sure to rinse soap off thoroughly and dry skin well.
  • Page 24: Mode Instruction

    8. Never apply electrodes over irritated or broken skin. MODE INSTRUCTION Modes & Functions Main Mode ICON Description Stimulating tapping is intended to produce a hard thumping Main Mode 1: sensation that Tapping massages your muscles, which can give you an invigorated and revitalized feeling.
  • Page 25 Mimic the sensation of suction created on the skin. Cupping is a traditional Chinese therapy in which Main Mode 4: heated glass cups are Cupping applied to the skin, creating suction as a way of stimulating the flow of energy. Simulation of Tuina is a hands-on body Main Mode 5:...
  • Page 26: Tens Ems Electrode Placement Guide

    8.TENS EMS ELECTRODE PLACEMENT GUIDE For TENS -25-...
  • Page 27 For EMS -26-...
  • Page 28: Troubleshooting

    Replace the pads. do not stick to skin pads need to be You can contact even after cleaning replaced. support@belifu.com and moistening the to purchase the pads. gel pad. Unit does not turn on Battery is low. Recharge the battery.
  • Page 29 Unit turns on, all of Always use two pads When you use two the modes and (one channel) or four pads (one channel) channels flash. Can pads (two channels) or four pads (two not select a mode at the same time as channels) at the it will not work with same time, make...
  • Page 30: Product Descriptions

    10.PRODUCT DESCRIPTIONS Product name TENS YF1503 Model Charge time About 2 hours Battery run time About 8 hours Lithium battery power supply 3.7V/180mAh Load resistance Output frequency 1Hz~110Hz Maximum pulse width 180uS Velocity Pulse Amplitude 0~98 Vpp Low voltage protection...
  • Page 31: Medical Disclaimer

    11.MEDICAL DISCLAIMER All information is intended for you general knowledge only and is not a substitute for medical advice or treatment for specific medical conditions. We cannot and do not give you medical advice. You should seek prompt medical care for any specific health issues and consult your health care provider before purchasing any product(s).
  • Page 32: Precautions

    Precautions to be taken in the event of changes in the performance of me equipment or me system Me equipment, me systems and accessories require professional hygienic maintenance prior to re-use. When the ME equipment is transferred to another patient, please contact us for the relevant service.
  • Page 33: Contraindications

    sensation. 5.Some patients may experience skin irritation or hypersensitivity due to the electrical stimulation or electrical conductive medium. The irritation can usually be reduced by using an alternate conductive medium, or alternate electrode placement. 6.Electrode placement and stimulation settings should be based on the guidance of the prescribing practitioner.
  • Page 34: Adverse Reaction

    implanted metallic or electronic device unless specialist medical opinion has first been obtained. Such use could cause electric shock, burns, electrical interference, or death. 14.ADVERSE REACTION stimulation electrodes applied to your skin. during or following the application of electrical stimulation near your eyes, to your head and face.
  • Page 35: Notes On Fcc Certification

    (broadcast, television, communications, operator should be away from the equipment or occasion as soon as possible if the essential performance of the equipment is degraded or lost due to EM DISTRUBANCES. The essential performance of the equipment should be restored. If not, please contact your seller. 15.NOTES ON FCC CERTIFICATION This device has been tested and found to comply with the limits for a Class B digital...
  • Page 36 - Consult the dealer or an experienced for help. - Consult the seller or support@belifu.com for help. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the device.
  • Page 37: Warranty

    4) Liability for direct or indirect consequential losses caused by the unit is excluded even if the damage to the unit is accepted as a warranty claim. 5) Anything about the device, please feel free to contact support@belifu.com -36-...