(7) TRACKING OFFSET ADJUSTMENT
. Connect
the oscilloscope's CH.
1 probe across
(+)
and
(—) on the Servo P.C.B., and its
CH. 2 probe (+) to VR102's
terminal.
Oscilloscope setting: VOLT
100 mV (CH. 1)
100 mV (CH. 2}
SWEEP........ 0.2 ms.
Input coupling. . AC (both CH. 1
and 2)
NORM
(trigger
CH. 1.)
Trigger mode...
DX-C201
DX-C101
a
EE
TIE
A
BE VN NE SN
aw J PC
AS ANS AUT
me He
PT
aD
ayite
Minimize the amplitude or make A = B.
Smooth
envelope
(8) TRACKING BALANCE ADJUSTMENT
. Set up the AF oscillator output for 1.1 kHz, 600 mVp-p,
and connect it to across the pins 1 and 2 of CN102.
=
2. Connect the oscilloscope's CH. 1. probe across
(+) to the pin 2 on the servo pc board.
Oscilloscope setting:
VOLT .............. 100 mV (CH. 1)
200 mV (CH. 2)
SWEEP. ............- 0.1 ms.
Input
coupling ........... AC
(both CH. 1 and
2)
Trigger mode ..NORM
(trigger CH. 2)
Switch the player power ON, and play the track C of
test disc. (YEDS-18)
Adjust VR106 until the section of the waveform marked
with * is balanced on CH. 1.
w
>
OSC
[
LOIS)
io) Z2 °
102
*
Checking Skip Search
1. Play an ordinary musical program disc.
2. Press the skip button
to check for normal
skip search
operation (in both the forward and reverse directions).
*
Checking Manual Search
. Play an ordinary musical program disc.
Press
the
manual
search
button
to check for smooth
manual
search
operations
at either
low or high speed
(in both the forward and reverse directions).
N=
=
*
nN
a
cj:
A
LE A
a
a een
al ial
alla || lla
a | a hg | lalall PN il jt
Al ,
* This section of the waveform must be balanced.
Checking Using Defect Disc
. Play the 0.7 mm
black dot and the 0.7 mm wedge on
the defect test disc (NR5A) and verify that no sound
skip or noise occurs.
Play the middle tracks of the uneven test disc and verify
that no sound skip or noise occurs.