INSTRUCTION MANUAL
MECHATROLINK I/O MODULE
(PNP transistor output, 32 points, screw terminal block,
MECHATROLINK- III use, external excitation 24V)
BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■ PACKAGE INCLUDES:
Discrete output module.......................................................(1)
DIN rail mounter slider ......................................................(2)
■ MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
MODEL
POINTS OF CAUTION
■ CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside the instrument
panel of a metal enclosure.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
■ POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, ≤ 110mA
■ GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and output signal for safety.
• Before you remove the terminal block or mount it, make
sure to turn off the power supply and output signal for
safety.
• DO NOT set the switches on the module while the power
is supplied. The switches are used only for maintenance
without the power.
■ ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■ WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
• Be sure to close the terminal cover for safety.
■ AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
R7K4FML3-6-DC32B
EM-7773-C Rev.3 P. 1 / 10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R7K4FML3-6-DC32B and is the answer not in the manual?

Questions and answers

Summary of Contents for MG R7K4FML3-6-DC32B

  • Page 1 • The unit is designed to function as soon as power is sup- plied, however, a warm up for 10 minutes is required for satisfying complete performance described in the data sheet. EM-7773-C Rev.3 P. 1 / 10 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 2: Component Identification

    Y24 Output 24 Y25 Output 25 Y26 Output 26 Y27 Output 27 Y28 Output 28 Y29 Output 29 Y30 Output 30 Y31 Output 31 EM-7773-C Rev.3 P. 2 / 10 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 3: Mounting Instructions

    [4 (.16)] 2 - 4.3 dia. 4 deep (2 - 1.17 dia. 7−M3 SCREW 36−M3 SCREW .16 deep) TERMINALS FOR POWER TERMINALS FOR OUTPUT EM-7773-C Rev.3 P. 3 / 10 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 4: Mounting Requirements

    It is possible to remove the terminal by loosening two screws of terminal alternately. *MECHATROLINK connectors are internally connected. The network cable can be connected to either one. EM-7773-C Rev.3 P. 4 / 10 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 5 Setup device command Not used CMD_CTRL CMD_STAT Refer to CMD_CTRL/CMD_STAT. Recalculation of parameters and set up. Other than 00H is not supported. ≥ 5 Reserve EM-7773-C Rev.3 P. 5 / 10 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 6 ≥ 8 Reserve • DISCONNECT (0FH) Stops communication with master station. BYTE COMMAND RESPONSE REMARKS DISCONNECT (0FH) DISCONNECT (0FH) Release connection command ≥ 1 Reserve EM-7773-C Rev.3 P. 6 / 10 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 7 CH2 data high 8 bits Not used CH3 OUT LO CH3 data low 8 bits Not used CH3 OUT HI CH3 data high 8 bits Not used EM-7773-C Rev.3 P. 7 / 10 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 8 Alarm 8: FCS error, 9: Command data not received, A: Synchronous frame not received, B: Synchronization time interval error, C: WDT error EM-7773-C Rev.3 P. 8 / 10 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 9 Sub Device 1 Version ---- Sub Device 2 Name ---- Sub Device 2 Version ---- Sub Device 3 Name ---- Sub Device 3 Version ---- EM-7773-C Rev.3 P. 9 / 10 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 10 Output 2 Output 18 Output 3 Output 19 Output 7 Output 23 Output 8 Output 24 Output 15 Output 31 0: OFF 1: ON EM-7773-C Rev.3 P. 10 / 10 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...