LG LRFCS25D3 Series Service Manual page 20

Hide thumbs Also See for LRFCS25D3 Series:
Table of Contents

Advertisement

7-5 Defrost Heater Error (dH E)
No
1
Check the
Door gasket
2
1.- Check for loose connection in defrost
control part connector.
2-. Check resistance of defrost control part.
3
Input Test 3 Mode.
(Push the button 3 times)
1.- Check for loose connection in
4
2. Check voltage between wires Brown to Blue.
5
Release the test mode.
Push the button 1 times. (Normal)
Checking flow
.
Fuse M
Def'
Sensor
Def'
Heater
CON3
.
Result & SVC Action
Part
Result
0 Ω
Fuse-M
Other
34 ~ 42 Ω
Def'
Heater
Other
21 Ω
Def'
Sensor
Other
Result
112 ~ 116 V
0 V
20
SVC Action
Go to the 3
Change Fuse-M
Go to the 3
Change Fuse-M
Go to the 3
Go to the 5
SVC Action
Go to the 5
Replace Main PCB