Download Print this page

Advertisement

Quick Links

INSTRUCTION MANUALS
Cosmopolitan
Series
®

Advertisement

loading
Need help?

Need help?

Do you have a question about the DA-LITE Cosmopolitan and is the answer not in the manual?

Questions and answers

Summary of Contents for LEGRAND DA-LITE Cosmopolitan

  • Page 1 INSTRUCTION MANUALS Cosmopolitan Series ®...
  • Page 2 Table of Contents Cosmopolitan ® Cosmopolitan (over 12' W) ®...
  • Page 3 INSTRUCTION MANUAL Cosmopolitan ®...
  • Page 4: Important Safety Instructions

    The content herein is subject to change without notice or obligation of any kind. To the maximum extent permitted by applicable law, Legrand AV makes no representation or warranty, expressed or implied, regarding the information contained herein.
  • Page 5: Installation

    Installation Keyhole For Wall Installation Overall length A = fabric width + 8". Length B is the distance between wall mounting holes at back of end caps and is the fabric width + 6 1/2". Motor End 4" 4" Fabric Height x Width As Ordered, Up To 9 Feet x 12 Feet 4 23⁄32"...
  • Page 6 Installation (continued) NOTE: Under no circumstances should unit be completely sealed in recessed installation. Allow access for service. Picture surface is centered in case. Case extends 4" beyond surface on either end. Do not attach anything to screen slat rod or bottom fabric pocket. 1.
  • Page 7 Installation (continued) Screen may be mounted on a wall, suspended from ceiling or extension brackets. Wall screens must be mounted level and with For Ceiling For Wall the case-back parallel to the wall. Wall Mounting Select fasteners of proper type for wall or ceiling involved. 2.
  • Page 8: 120V Wiring Diagram

    120V Wiring Diagram NOTE: A single switch cannot be used to operate more than one screen. Contact the factory for further information. Wiring Enclosure Cover To Junction Box, Mounted In Screen Case, In Which Internal Wiring Terminates In White, Black and Red Leads Down White Limit Switch...
  • Page 9 120V Wiring Diagram with Optional Built-In Low Voltage Control Wall Switch 120V Wiring Diagram IMPORTANT NOTE: The wall switch is REQUIRED to make any limit switch RJ-45 Input adjustments, EVEN if a third party control system is used. Therefore, it is advised to locate the wall switch in an Junction Box Cat5e or Cat6 Cable...
  • Page 10 220V Wiring Diagram For Screens Without A Built-In Low Voltage Control - Rocker Switch NOTE: A single switch cannot be used to operate more than one screen. In multiple control installations this switch is replaced by the low voltage control, operated from push button stations. Contact the factory for further information. Black (Up) To Junction Box, Mounted In Screen Case, Brown (Down)
  • Page 11 230V Wiring Diagram with Optional Built-In Low Voltage Control Wall Switch 230V Wiring Diagram IMPORTANT NOTE: The wall switch is REQUIRED to make any limit switch RJ-45 Input adjustments, EVEN if a third party control system is used. Therefore, it is advised to locate the wall switch in an Junction Box Cat5e or Cat6 Cable...
  • Page 12 230V Wiring Diagram with Optional Built-In Low Voltage Control (continued) 230V Wiring Diagram with Opitonal European Style Wall IMPORTANT NOTE: The European style wall switch is for Switch operation only and CANNOT be used to make limit switch adjustments. Therefore, it is advised to locate the limit Use 3-conductor 20–24 gauge wire to connect European style adjustment wall switch in an accessible location.
  • Page 13: Screen Adjustment

    Screen Adjustment Surface travel is stopped automatically in the fully opened and closed positions by limit switches that are properly adjusted at Da-Lite. Should it be necessary to adjust for more or less picture drop (viewing area), proceed in the following manner: CAUTION: Do not adjust for more drop than what was ATTENTION! N'effectuez pas de réglage pour obtenir un ordered.
  • Page 14 Screen Adjustment (continued) For Screens With A Built-In Low Voltage Control the desired travel position is reached. If you travel to far up 1. Locate the wall switch and remove the cover plate from you can press the down to move the screen downward. If you the 3-button wall switch and remove the switch from the press and let go of either up or down button the motor will junction box.
  • Page 15 Operation of Screens With A Built-In Low Voltage Control Operation & Limit Adjustment Wall Switch “Up” Button Press “DOWN” button on screen switch and screen will deploy out of case in downward direction. “Stop” Button 2. Press “STOP” button on screen switch and screen will stop if in movement.
  • Page 16: Troubleshooting

    Troubleshooting Symptom Cause Solution Verify 115-125V (or 220-240V). If insufficient voltage, rewire Incorrect line voltage. Screen will not operate. incoming electric line. Motor does not hum. Blown fuse. Replace fuse. Tripped circuit breaker. Reset circuit breaker. Check above. Tighten all loose wire connections. Correct any improper connections.
  • Page 17 LIMITED FIVE-YEAR WARRANTY ON DA-LITE PRESENTATION PRODUCTS Legrand AV Inc. warrants certain Da-Lite branded products to the original purchaser only, to be free from defects in materials and workmanship for a period of five (5) years from the date of purchase by the original purchaser; provided they are properly operated according to Da-Lite's instructions and are not damaged due to improper handling or treatment after shipment from the factory.
  • Page 18 P +852 2145 4099 E av.asia.sales@legrand.com COMMERCIAL BRANDS © 2020 Legrand AV Inc. 200054 (REV 4) 3/20 Da-Lite is a registered trademark of Legrand AV Inc. All other brand names or marks are used for identification purposes and are trademarks of their respective Chief | Da-Lite | Middle Atlantic | Projecta | Vaddio owners.
  • Page 19 INSTRUCTION MANUAL Cosmopolitan (over 12' W) ®...
  • Page 20 The content herein is subject to change without notice or obligation of any kind. To the maximum extent permitted by applicable law, Legrand AV makes no representation or warranty, expressed or implied, regarding the information contained herein.
  • Page 21 Installation The Large Cosmopolitan Electrol comes with brackets to allow for wall mount or ceiling mount installations. Procedures for each method are as follows: Wall Mount 1. Remove the four ceiling mount brackets from the wall mount bracket. 2" 2. The wall mount bracket should be fastened to wall studs or some reinforcement within the wall.
  • Page 22 120V Wiring Diagram For Screens Without A Built-In Low Voltage Control Internal wiring has been completed at the factory. Installer must route power to the wall switch and to the junction box located on the left end of the screen case. See wiring diagram below for wire connections.
  • Page 23 120V Wiring Diagram with Optional Built-In Low Voltage Control Wall Switch 120V Wiring Diagram IMPORTANT NOTE: The wall switch is REQUIRED to make any limit switch RJ-45 Input adjustments, EVEN if a third party control system is used. Therefore, it is advised to locate the wall switch in an Cat5e or Cat6 Cable Junction Box...
  • Page 24 230V Wiring Diagram For Screens Without A Built-In Low Voltage Control - European Switch NOTE: A single switch cannot be used to operate more than one screen. In multiple control installations this switch is replaced by the low voltage control, operated from push button stations. Contact the factory for further information. Black (Up) To Junction Box, Mounted In Screen Case, Brown (Down)
  • Page 25 230V Wiring Diagram with Optional Built-In Low Voltage Control Wall Switch 230V Wiring Diagram IMPORTANT NOTE: The wall switch is REQUIRED to make any limit switch RJ-45 Input adjustments, EVEN if a third party control system is used. Therefore, it is advised to locate the wall switch in an Cat5e or Cat6 Cable Junction Box...
  • Page 26 230V Wiring Diagram with Optional Built-In Low Voltage Control (continued) 230V Wiring Diagram with Opitonal European Style Wall IMPORTANT NOTE: The European style wall switch is for Switch operation only and CANNOT be used to make limit switch adjustments. Therefore, it is advised to locate the limit Use 3-conductor 20–24 gauge wire to connect European style adjustment wall switch in an accessible location.
  • Page 27 Screen Adjustment For Screens Without A Built-In Low Voltage Control Screen travel is stopped automatically in the down and up positions by the limit switches that are preset at the factory. No further adjustment is necessary. If you need to make minor stop position adjustments see the appropriate step below. SETTING THE DOWN LIMIT POSITION NOTE: One turn of the limit screw equals approximately 2"...
  • Page 28 Screen Adjustment For 120V Screens With A Built-In Low Voltage Control Locate the wall switch and remove the cover plate from the position is reached. If you travel to far up you can press the down 3-button wall switch and remove the switch from the junction box. to move the screen downward.
  • Page 29 Troubleshooting Symptom Cause Solution Blown fuse. Replace fuse. Tripped circuit breaker. Reset circuit breaker. Check above. Tighten all loose wire connections. Correct any improper connections. No power to operating switch Down Position or junction. Check for power across black and white leads. Up Position Screen will not operate.
  • Page 30 LIMITED FIVE-YEAR WARRANTY ON DA-LITE PRESENTATION PRODUCTS Legrand AV Inc. warrants certain Da-Lite branded products to the original purchaser only, to be free from defects in materials and workmanship for a period of five (5) years from the date of purchase by the original purchaser; provided they are properly operated according to Da-Lite's instructions and are not damaged due to improper handling or treatment after shipment from the factory.
  • Page 31 P +852 2145 4099 E av.asia.sales@legrand.com COMMERCIAL BRANDS © 2023 Legrand AV Inc. 200053 (REV 1) 12/23 Da-Lite is a registered trademark of Legrand AV Inc. All other brand names or marks are used for identification purposes and are trademarks of their respective Chief | Da-Lite | Middle Atlantic | Projecta | Vaddio owners.