2 Conditions of use 2.1 Intended use The ZL160N is engineered to command A SINGLE OPERATOR for swing gates of the FLEX 24V (DC) series. Any installation and use other than that specified in this manual is forbidden. 2.2 Application settings Respect cable distances and diameters as shown in the "Cable tyeps and sections"...
4.1 Dimensions, centre distances and anchoring holes (mm) 8.2 Main components 1 Connecting terminals 2 1.6 A line fuse 3 3.15A accessories fuse 4 Buttons to memorise radio code 5 Working time adjuster trimmer 6 Automatic closing time adjuster trimmer 7 4-way DIP SWITCH functions selector (see p.
5 Installation 5. 1 Preliminary checks Before beginning to install, the following is necessary: Make sure that the point where the electrical panel is anchored is free from any impacts, and that the surface is solid and that proper tools and materials are used (i.e. screws, wall plugs, etc.). Set up a suitable omnipolar cut-off device, with distances greater than 3 mm between contacts, with sectioned power source •...
6 Electrical connections Gearmotor 24 V DC Gearmotor For mounting on the right side invert the connection cables: (M-Red, N-Green) Power supply Terminals for powering the Power supply to the 24V AC accessories. 230V AC 50/60 Hz Overall allowed power: 40 W control panel Electro lock connection (12V- 15 max.)
Page 6
Lighting and warning devices Gate open warning light Contact rated for: 24 V - 3 W Max.)- Warns of open gate position, turns off when gate is closed. Movement Flasher (contact rated for: 24V AC - 25W Max.) - Flashes while gate opens and closes. Safety devices Delta-S "Reopening when closing (N.C.) Contact»...
Command devices Stop button ( (N.C.) contact. ) Gate stop button with exclusion of automatic closing, to resu- me movement press command button or transmitter button. if unused Key switch selector and/or command button (N.O. contact) - Gate opening and closing commands, pressing the button or turning the key switch selector, the gate inverts its movement or stops depending on selection made on the DIP switches (see selecting functions, DIP switches 2-10)
9 Activating the radio command Antenna Connect RG58 antenna cable to the apposite terminals. Transmitters See instructions sheet in the packa- ge of the AF43SR radiofrequency card...
Page 9
Radio frequency card Only for the AF43S / AF43SM radio-frequency cards: - position jumper as shown depending on the series of transmitters you are using. Frequency Scheda Series radiofrequenza transmitters FM 26.995 AF130 FM 30.900 AF150 AM 26.995 AF26 AM 30.900 AF30 AM 433.92 AF43S / AF43SM...
Page 10
Memorisation Memorise the code onto the card, as follows: 1) Keep pressed the "PROG" button on the base board (the LED light flashes). Flashing LED AF radio frequency card 2) The transmitter button sends the conde, and the LED will stay on to signal that memorisation was succesful. LED stays lit AF radio frequency card...
UNI EN ISO 14001 standard to ensure environmental protection. Please help us to safeguard the environment. At CAME we believe this to be one of the fundamentals in its market operations and development strategies. Just follow these short disposal instructions: DISPOSING OF THE PACKAGING The components of the packaging (i.e.