Sony TRINITRON KV-B2531A Service Manual page 47

Table of Contents

Advertisement

| KV-M254
SECTION 3
SET - UP ADJUSTMENTS
When complete readjustment is necessary or a new
picture tube is installed, carry out the following
adjustments.
Unless there are specific instructions to the contrary,
carry out these adjustments with the rated power
supply.
Unless there are specific instructions to the contrary, set
the controls and switches to these settings :
4.
¢
Carry out the following adjustments in this order :
1.
Beam landing
2.
Convergence
3.
Focus
*
4.
White balance
Note: Testing equipment required.
1. Color bar/pattern generator
2. Degausser
CD Contrast
80%
(or remote control
3. DC power supply
normal)
4. Digital multimeter
x Brightness ...........
50%
5. Oscilloscope
Preparation:
In order to reduce the influence of geomagnetism on
the set's picture tube, face it east or west.
Switch on the set's power and degauss with the
degausser.
3-1. BEAM LANDING
Ll.
Input the white signal with the pattern generator.
CONTRAST
\ ee
BRIGHTNESS
Position neck assy as shown in Fig.3-2.
Set the pattern generator raster signal to red.
Move the deflection yoke forward and adjust with the
purity control so that the red is at the center and the
blue and the green take up equally sized areas on
each side. (See Fig. 3-1 - 3-3)
Move the deflection yoke forward and adjust so that
the entire screen becomes red. (See Fig. 3-1)
Switch the raster signal to blue, then to green and
verify the condition.
When the position of the deflection yoke has been
decided, fasten the deflection yoke with the screws.
If the beam does not land correctly in all the corners,
use a magnet to adjust it. (See Fig. 3-4)
Disk magnets or
rotatable disk
magnets correct
these areas (a - d).
Purity control corrects
this area.