Miscellaneous - Medisana 61158 Instruction Manual

Heat pad for shoulders and back
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
GB
2 Operating / 3 Miscellaneous
2.3 Operating
Make sure, the connection cable of the control unit is properly connected to the
plug of the heat pad. Plug the unit into the mains outlet and move the slider control
from position 0 to position 1. The power LED will light up in orange (warm up
phase) and after reaching the final temperature level it will light up in green.
After a few minutes you will be able to feel the pad getting noticeably warmer. If
you require a higher temperature setting, move the switch to the next positions 2
or 3 or the maximum heat setting, position 4. If the heat pad gets too hot for you,
move the slider back to position 3, 2 or 1. After a short time, the heat pad will cool
down. The heat pad has an accurate electronic control system. Depending on the
room temperature, the LED may change from orange to green colour and back
within seconds. This indicates the fast re-heating and is normal.
To switch the unit off, move the switch back to position 0. The power LED will go
out, indicating that the unit is switched off. Unplug the unit from the mains outlet.
Move the switch to position 1 for any continuous use. The heat pad will switch
off automatically after approx. 90 minutes of continuous use. To switch it back on
again, move the slider switch to position 0 and then back to the desired heat
setting. Unplug the unit from the mains outlet once you have finished using it.
The particular shape is especially designed for use on shoulders, neck
and back. Using the heat pad stimulates blood circulation in hardened muscles and
helps you to relax after a strenuous day.
The heat pad features an electric temperature control that regulates the temperature
according to the chosen setting. The two snap buttons on the front part and the prac-
tical belt keep the heat pad for shoulders and back HP 630 in ist position.

3 Miscellaneous

3.1 Troubleshooting
This unit is equipped with the active protection system APS TECH. The unit detec-
ts different causes of errors and emits corresponding alarm sounds if necessary. In
the case of an error, the power LED will light up in red.
3 beeps in 1-second interval and power LED lights up in red:
The connection cable of the control unit is not properly connected to the heat pad or
another electrical defect is present. Please check the cable connection. Is the cable
connected properly, please do not use the heat pad and contact the service center.
3 beeps in 2-second interval for one minute and power LED lights up in red:
The heat pad is broken, folded or fully covered. Please use the heat pad only
according to this instruction manual and pay attention to all points in the safety
information chapter.
Constant beeping and power LED lights up in red:
Important components are damaged or there is a short circuit. Please do not use
the heat pad and contact the service center.
If there is no function at all after switching on the heat pad (power LED shows
no light and no beeps can be heard), please check if the mains plug is correctly
plugged in the mains outlet. If this is the case, the heat pad is defect. Please do
not use the heat pad and contact the service center.