Sony AC-500CE Operation And Maintenance Manual page 22

Ac adaptor
Table of Contents

Advertisement

Serial No. 29396
and higher (U/C)
Serial
No. 22850
and
higher (AEP)
Serial No. 14091
and higher (J)
SCHEMATIC DIAGRAM
Q202escisi0
CNI5
EXT VBS
CN13
DC OUT
FEMALE
(WIRING
SIDE)
| 225325
VPP
CNI6
VIDEO
OUT
MIC OUT
{USA/END,
AEP; MALE, WIRING
SIDE)
(JAPAN; FEMALE
,EXTERNAL
VIEW)
NOTE
[MARK |
CHANGE
INFORMATION
m1
R106
180 —*
220
U/C s10751~
vo
10481~
1105S1~
R221
750 —> 1K
|
TO HEAT SINK
(AC-157P....
'
[NO LOABfeA CUTPUTTAC
SOURCE]
M2716 ~
:10781~
TN701~
Q209 ~ Q212
28C2023 —»
2sSc¢2542
s
MAGNET
x6
:21650~
RUSH CURRENT LIMIT
o OUTPUT
VOLTAGE
(Vv)
—1_
(WIRING
SIDE)
CB101
315A
250v
Fe
SA
250V
C8102, CBI03
DELETED
°
200
400
600
MAGNETIC
FLUX
DENSITY
(GAUSS)
VOLTAGE SELECTOR
(WIRING
SIDE)
_ 100V 1-9,2=4
120V 3-9,4-6
220v 7-9,2-8/ G) ®
@
240V
5-9, 6-8
()
@
©
A
PL4
POWER ( C )
6V 35mA
8
NOTE:
WHEN
IC201
IS REPLACED
FROM
ULN3006T
TO ULN3006T-W, THE
NUMBER
OF
TURN
ON L206
SHOULD
BE DECREASED
FROM
11 TO 6 TURNS.