Page 1
Operation Manual V 2.0 Sub-Series SW-12 MiniSub Ultra-Compact Subwoofer Keep these important operating instructions. Check www.tecnare.com for updates.
Page 3
EXEL ACOUSTICS SL CL Encinar, 282 – Pol. Ind. Monte Boyal 45950 Casarrubios del Monte (Toledo) Spain Phone: (+34) 918 170 110 Fax: e-mail: support@tecnare.com www.tecnare.com 2.00 Subwoofer Series | rev.
SW-12 MiniSub Operation Manual IMPORTANT SAFE INSTRUCTIONS Before using our product, be sure to carefully read the manual and safe Instructions. Keep this document with the device all time. Read these instructions. health. Hearing damage can also occur with prolonged exposure to sound: 8h at 90 Keep these instructions.
SW-12 MiniSub Operation Manual DECLARACIÓN DE CONFORMIDAD DECLARATION OF CONFORMITY EXEL ACOUSTICS SL CL Encinar, 282. Polígono Industrial Monte Boyal. 45950 – Casarrubios del Monte (Toledo), España (Spain). Declara que el producto SW-12 MiniSub y sus respectivas opciones, cumple con las Directivas: Declare under our sole responsibility that devices in the SW-12 MiniSub range of products, comply with relating Directives: (1) Directiva de Baja Tensión - 2006/95/CE...
All Tecnare products are carefully engineered for world-class performance and reliability. ® If you would like further information about this or any other Tecnare product, please contact us. We look forward to helping you in the near future. As part of a continuous evolution of techniques and standards, Exel Acoustics ®...
The Tecnare SW12Minisub is a very powerful 1×12-inch Low-Frequency loudspeaker enclosure. This vented subwoofer cabinet has been designed for small sound reinforcements, where audio quality and box size matters. It extends the power bandwidth of other Tecnare loudspeakers, enhancing the low-frequency headroom in a variety of full range systems.
SW-12 MiniSub Operation Manual Connections ® ® SW-12 loudspeaker utilizes Neutrik SpeakON connectors. There are two NLT4 connectors on the rear of each SW-12. These connectors mate with Neutrik NL-4 or NL-4 compatible in-line cable connectors. All four pins of both connectors are wired in parallel. The following subsections describe the electrical connections.
In certain specific cases it is possible to slightly under-power the subs or loudspeakers as long as the amplifier will not be driven to its limits. In any case, the Tecnare processors should be deployed in front of the amp to ensure that the amplifiers to not go into clip.
SW-12 MiniSub Operation Manual Loudspeaker Configuration Standard Operation The standard operation corresponds to the use of subwoofers as single elements or as standard subwoofer arrays. In this configuration the system operates with an omni-directional or quasi-omni- directional directivity pattern. SW-12 Standard operation 2.00 Subwoofer Series | rev.
The output of the reversed subwoofer cancels the output of the other subwoofers normally present behind the units. Tecnare has specifically designed cardioid presets. However, we recommend calculating the appropriate ratio of forward to rear facing loudspeakers, as well as the measurement of required parameter setting of polarity, delay, and gain.
Tecnare loudspeaker controllers. ® Tecnare only recommends using preset/amplifier developed by Tecnare; otherwise there is a risk of damaging the loudspeaker components. DP Series Loudspeaker Controller, PA Series amplifier and T-Series amplifier are ideal for this purpose. Ensure that the right preset was selected before connecting the loudspeaker with the amplifier.
Operation Manual Connection to PA3000/PA5000 MAXIMUM OF 4 ENCLOSURES PER PA3000/5000 2 x SW-12 can be connected to each output channel on the PA3000/5000. Therefore, a single PA3000/5000 amplifier can drive up to 4 enclosures. See the preset manual connect the reverse subwoofer to use the cardioid preset. Impedance load: 8Ω...
SW-12 MiniSub Operation Manual Connection to T20-44/T10-44 MAXIMUM OF 16 ENCLOSURES PER T20-44/T10-44 4 x SW-12 can be connected to each output channel on the T20-44/T10-44. Therefore, a single T20-44/T10-44 amplifier controller can drive up to 16 enclosures. See the preset manual connect the reverse subwoofer to use the cardioid preset. Impedance load: 8Ω...
Page 18
Operation Manual 2.00 Subwoofer Series | rev.
Page 19
Exel Acoustics. Tecnare and PCC-Net are trademarks of Exel Acoustics SL. Podware, System Engineer, BvNet and all third-party trademarks mentioned herein are the property of their respective trademark holders.
Need help?
Do you have a question about the Sub Series and is the answer not in the manual?
Questions and answers