Matelec FSA-60000 Quick Start Manual

Matelec FSA-60000 Quick Start Manual

240vac c/w 3v dc battery backup photoelectric smoke alarm

Advertisement

Quick Links

240Vac c/w 3V DC Battery Backup
Photoelectric Smoke Alarm
Thank you for purchasing a MATelec Australia Smoke Alarm.
Please read this user's manual thoroughly to familiarise yourself with the operation of the
Important Information
This smoke alarm MUST be installed in
accordance with national and local council
building regulations, state fire department
requirements and the latest edition of the
Australian and New Zealand wiring Rules AS/
NZS 3000. Building codes and regulations
may vary from each state jurisdiction.
Distributor
MATelec Australia
Address: 5 Telford Drive, Shepparton VIC 3630
Postal Address: PO Box 7093, Shepparton VIC 3632
Phone: 1800 281 282
Fax: 1300 281 282
Email: info@matelecaustralia.com.au
Product Code: FSA-60000
smoke alarm before use.
1
Product specifications
Sensing Type
Power Supply
Back-up Battery
(Power Supply)
Interconnectivity
Interconnection
Size
Temp Range
Max Humidity
"Alarm Signal
Pattern"
Alarm Volume
Hush Time
Compliance
Certification
Photoelectric (Type A -
contains no radioactive
material)
220-240V AC 50Hz
Replaceable DC 3V
battery: CR17450
10 year backup Lithium
Hard wired OR Wireless
Module, FSA-50000
(supplied separately)
Maximum 24 paired
alarms
Max wiring length
between first
and last alarm: 150 m
o135mm x 45mm
0°C - 45°C
93%RH
ISO 8201
85dB at 3m
10 mins
AS 3786: 2014
CSIRO Verification
Service

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FSA-60000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Matelec FSA-60000

  • Page 1 240Vac c/w 3V DC Battery Backup Photoelectric Smoke Alarm Product Code: FSA-60000 Thank you for purchasing a MATelec Australia Smoke Alarm. Please read this user’s manual thoroughly to familiarise yourself with the operation of the smoke alarm before use. Product specifications...
  • Page 2: Avoid These Locations

    50cm NOT 50cm NOT 12” IN THIS (30cm) 12” IN THIS AREA Minimum CEILING (30cm) AREA Minimum CEILING DEAD AIR DEAD AIR 100cm 4” 100cm (10cm) ANYWHERE IN 4” Minimum (10cm) ANYWHERE IN THIS AREA Minimum NOT IN THIS AREA NOT IN THIS AREA THIS AREA...
  • Page 3: Test Procedure

    Pressing and holding the TEST button on FSA-50000 wireless module (not included). any smoke alarm for at least 5 seconds NOTE: Matelec Australia smoke alarms must will cause unit to ALARM and the not be interconnected with any other brands LED to flash.
  • Page 4: Wireless Pairing

    NOTE: If the alarm sounds, first ensure there Both indicates units have successfully paired. is NO DANGER. Do not assume it is a false The MASTER (FSA-60000) alarm LED will then alarm. Carefully check residence for the remain until another pairing request is presence of smoke.
  • Page 5: Troubleshooting Guide

    TEST button released Chirps once every Weekly self-test Flash once If the above rectification steps do not rectify week the issue at hand, contact MATelec for tech Chips every 40 Flashes once End of Life (10 support. seconds...
  • Page 6: Maintenance

    Do not spray any cleaning liquids directly Warranty onto/into the smoke alarm. If the low battery alarm sounds, replace battery. This MATelec Smoke Alarm is designed for use in residential dwellings and is warranted as such. Test Smoke The FSA-60000 smoke alarm is warranted...