elobau 4621273E Operating Manual

elobau 4621273E Operating Manual

Safety evaluation unit
Hide thumbs Also See for 4621273E:

Advertisement

Operating manual
Version: 2.1
No.: 9010041B01M
Safety evaluation unit
4621273E, 4621213E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4621273E and is the answer not in the manual?

Questions and answers

Summary of Contents for elobau 4621273E

  • Page 1 Operating manual Version: 2.1 No.: 9010041B01M Safety evaluation unit 4621273E, 4621213E...
  • Page 2: Table Of Contents

    Material information ...................... 13 4.2.5 Connection........................13 4.2.6 Terminal connections....................14 4.2.7 Safety-relevant parameters ..................15 Circuit diagram 4621273E................. 16 Circuit diagram 4621213E................. 16 Set up, installation, putting into service Installation ......................17 5.1.1 Control output ....................... 17 5.1.2 Mounting position......................17 Electrical connection ..................
  • Page 3: User Information

    1. User information User information Copyright The copyright for this Operating manual remains with elobau GmbH & Co. KG. This Operating manual contains technical regulations and drawings which may not be reproduced, distributed, utilised or made available to third parties, either in whole or in part, without our permission. Infringements shall result in punishments and the obligation to pay damages (as per UWG BGB).
  • Page 4: Functional Principle

    This means that the out- put is opened or closed depending on the status of the safety sensors. The product must be used only in accordance with the descriptions below for protection against dangers. 4 / 24 www.elobau.com 9010041B01M...
  • Page 5: Foreseeable Misuse

    1. User information Observe all applicable health and safety conditions, laws and directives of the respective machine. There are no known residual risks, if all of the infor- mation contained in this operating manual is complied with. Every non-intended use and all activities performed that are not described in this manual represent a prohibited, incorrect use outside the legal limits of liability of the manufacturer.
  • Page 6: Approvals

    Approvals The following approvals have been granted for the product: TÜV NORD [AUXILIARY DEVICE] E334998 Manufacturer elobau GmbH & Co. KG Zeppelinstraße 44 D-88299 Leutkirch +49-7561-970-0 www.elobau.de info@elobau.com 6 / 24 www.elobau.com...
  • Page 7: Abbreviations

    Tabelle 1 Variants and type code The following combinations for various system features are possible: • 4621273E • 4621213E The 6th position of the article number describes the type of operating volta- ge. More information can be found in chapter 4.2.6 Terminal connections, page 14.
  • Page 8: Definition Of Personnel Groups

    The specialist person- nel must have read and understood the Operating manual. It is recommen- ded that the specialist personnel are trained by elobau. 8 / 24 www.elobau.com...
  • Page 9: Conformity

    3. Transport and storage Conformity The product Safety evaluation unit conforms to the state of the art plus the applicable safety conditions at the time of bringing into circulation within the scope of its intended use. From a design point of view, foreseeable misuse cannot be avoided without limiting the intended functionality.
  • Page 10: Product-Specific Information

    4. Product-specific information Product-specific information Mechanical data (mechanical design) Abbildung 1 10 / 24 www.elobau.com 9010041B01M...
  • Page 11: Electrical Data

    4. Product-specific information Electrical data 4.2.1 Electrical parameters Unit Value Value 4621273E 4621213E Min. switching voltage on DC safety output V DC Max. switching voltage on DC safety output V DC Max. switching voltage on DC control output V DC Min.
  • Page 12: Parameters For Ul Approval

    Parameters for UL approval Cat. no. Input Output to Sen- Safety output Control output 4621273E 24 V AC/V DC, Max. 12 V DC Max. 4 A Max. 3 A max. 250 V AC /24 V DC max. 250 V AC /...
  • Page 13: Ambient Conditions

    4. Product-specific information 4.2.3 Ambient conditions Unit Value Value 4621273E 4621213E Single device protection class IP20 Protection class of single device in installation space IP54 Min. operating temperature °C Max. operating temperature °C Min. storage temperature °C Max. storage temperature °C...
  • Page 14: Terminal Connections

    Not suitable for safety functions! Switching dependent on: Control output 24-26 • Safety input 1-4 • EDM input 24 V AC/DC (4621273E) Operating voltage 24 V DC (4621213E) Tabelle 7 Information Complete protective insulation in accordance with DIN EN 61140 is provi- ded if the Safety evaluation unit is installed in a switch cabinet for operation.
  • Page 15: Safety-Relevant Parameters

    4. Product-specific information 4.2.7 Safety-relevant parameters Value Value 4621273E 4621213E PL according to EN ISO 13849-1 SIL CL according to IEC 62061 5.77 x10 5.81 x10 Service life (in years) Category according to EN ISO 13849-1 Hardware fault tolerance (HFT) Max.
  • Page 16: Circuit Diagram 4621273E

    4. Product-specific information Circuit diagram 4621273E Abbildung 2 Circuit diagram 4621213E Abbildung 3 16 / 24 www.elobau.com 9010041B01M...
  • Page 17: Set Up, Installation, Putting Into Service

    Signal path of the output signal is generally depicted on the data sheet or is made available by elobau on request. Please pay attention to temperature drift. Installation of the Safety evaluation unit is only permitted in a voltage- free state.
  • Page 18: Electrical Connection

    Only use the Safety evaluation unit if it is not damaged. Putting the Safety evaluation unit into operation 1. Actuate the safety sensors. 2. Apply the operating voltage. The safety evaluation unit is ready for operation and switches through the safety output. 18 / 24 www.elobau.com 9010041B01M...
  • Page 19: Operation / Control

    6. Operation / control Information Note that the EDM input must be bridged if no external contactors are used. WARNUNG! Danger due to lack of complete validation! When installing the safety evaluation unit, the “normally-closed” and “nor- mally-open” contacts could be mixed up. Commissioning the system wit- hout a legally prescribed complete validation may then result in personal injury, property damage or environmental damage.
  • Page 20: Error Messages, Troubleshooting

    Flashing ting time error Tabelle 12 Information Not all errors are indicated externally by a flash code. Restoration of operational readiness If the safety output has been opened by a triggered sensor contact, for example. 20 / 24 www.elobau.com 9010041B01M...
  • Page 21: Maintenance And Servicing

    7. Maintenance and servicing Restore operational readiness. 1. Ensure that the connected, external contactor has dropped. 2. Ensure that the normally-open contact of the corresponding sensor is open and the normally-closed contact is closed. 3. Close the contact on the corresponding sensor normally-closed contact input.
  • Page 22: Decommissioning

    The symbol means that a product must be collected separately from other waste when it reaches the end of its service life in accordance with directive 2012/ 19/EU. For more information, please contact elobau or your dealer on site. Dispose of packaging and used parts in accordance with the relevant national regulations.
  • Page 23: Eu Declaration Of Conformity

    8. EU Declaration of Conformity EU Declaration of Conformity elobau GmbH & Co. KG Zeppelinstraße 44 88299 Leutkirch www.elobau.com EU-Konformitätserklärung EC Declaration of Conformity Hiermit erklären wir, dass das nachfolgend aufgeführte Produkt aufgrund der Konzipierung und Bauart den Sicherheits- und Gesundheitsanforderungen der unten genannten EU- Richtlinien entspricht.
  • Page 24 8. EU Declaration of Conformity DocuSign Envelope ID: A67661D9-78C2-4009-82E6-9B6A1E26F76D elobau GmbH & Co. KG Zeppelinstraße 44 88299 Leutkirch www.elobau.com Die Übereinstimmung eines Baumusters mit der oben benannten Richtlinie wurde bescheinigt durch: The consistency of a model with the above-named Directive has been certified by: Name und Anschrift TÜV Nord CERT GmbH...

This manual is also suitable for:

4621213e