Page 1
REGULATORS SLIMLINE 2 OCTO SECOND STAGE OCEANIC ® SLIMLINE 2 OCTO SERVICE PROCEDURE This SlimLine 2 Service Procedure conveys a list of components and service procedures that reflect the SlimLine 2 as it was configured at the time of this writing (2/19/05).
REGULATORS SLIMLINE 2 OCTO SECOND STAGE CONTENTS TROUBLESHOOTING ................................. 3 DISASSEMBLY PROCEDURE ..............................4 REASSEMBLY PROCEDURE ..............................5 FINAL TUNING AND TESTING ..............................7 PARTS LIST AND EXPLODED VIEW DIAGRAM ........................10 GENERAL PROCEDURES REFER TO ................................DOC. 12-2202 SPECIFICATIONS...
REGULATORS SLIMLINE 2 OCTO SECOND STAGE TROUBLE SHOOTING SYMPTOM POSSIBLE CAUSE TREATMENT * Free flow or leakage present. 1. Excessive LEVER ARM (9) height. 1. Adjust ORIFICE (2) and LOCK 2. Excessive Intermediate Pressure NUT (12) to arrive at correct from First Stage.
REGULATORS SLIMLINE 2 OCTO SECOND STAGE DISASSEMBLY PROCEDURE NOTE: Be sure to perform the steps outlined in the Initial Inspection Procedures Doc 12-2022 prior to disassembling the Regulator. Review the Troubleshooting Section to gain a better idea of which internal Parts may be worn, and to better advise your customer of the service that is needed.
WARNING: Use only genuine Oceanic Parts, Subassem- blies, and Components whenever Assembling Oceanic prod- ucts. DO NOT attempt to substitute an Oceanic Part with another manufacturer’s, regardless of any similarity in shape, size, or appearance. Doing so may render the product unsafe, and could result in serious injury or death of the user.
Page 6
REGULATORS SLIMLINE 2 OCTO SECOND STAGE 4. Apply a light film of lubricant to each end of the POPPET SPRING (7) and place onto the POPPET (6). Fit the POPPET into the Pronged end of the Poppet Tool and insert the Shaft of the POPPET...
13. Place the FRONT COVER RING (16) down over the FRONT COVER (17) and hand tighten clockwise until secure and in proper alignment, attained when the Oceanic logo faces the MOUTH- PIECE (18) (Fig. 13). Use the Front Cover Tool, if necessary. DO NOT overtighten.
Page 8
REGULATORS SLIMLINE 2 OCTO SECOND STAGE 4. Slowly open the valve to pressurize the Regulator, and check the Test Gauge to ensure that the Intermediate Pressure is set as recommended in the Specifications for the First Stage used. NOTE: If the Intermediate Pressure is found to be other than recommended, refer to that Regulator's Trouble Shooting Section to determine possible cause and treatment.
Page 9
REGULATORS SLIMLINE 2 OCTO SECOND STAGE 4. Hold the Second Stage with the MOUTHPIECE facing directly down, and gently shake it up and down. Listen carefully for any rattle that may be present, indicating LEVER ARM slack. If LEVER ARM slack is present, perform the following procedure: A.