AWILCO ES-2002 Owner's Manual

Energy system es-2002 lithium powerpack / 2000w-100ah imd - insulation monitoring device

Advertisement

Quick Links

AWILCO
ENERGY SYSTEM ES-2002
LITHIUM POWERPACK / 2000W-100AH
IMD - Insulation Monitoring device
ES-2002, EUROPE (230V)
ES-2002UK, UNITED KINGDOM (230V)
OWNER'S MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ES-2002 and is the answer not in the manual?

Questions and answers

Summary of Contents for AWILCO ES-2002

  • Page 1 AWILCO ENERGY SYSTEM ES-2002 LITHIUM POWERPACK / 2000W-100AH IMD - Insulation Monitoring device ES-2002, EUROPE (230V) ES-2002UK, UNITED KINGDOM (230V) OWNER’S MANUAL...
  • Page 2 While every precaution has been taken to en- sure the accuracy of the contents of this guide, Web: www.awilco.dk AWILCO ApS assumes no responsibility for errors or omissions. Note as well that specifications and product functionality may change without notice.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS: IMPORTANT SAFETY INFORMATION 1. INTRODUCTION 2. PRODUCT DESCRIPTION 3. INSTALLATION 4. CONNECTING TO BLUETOOTH 5. INVERTER/CHARGER OPERATION 6. FEATURE SETTING 7. TROUBLESHOOTING 8. SPECIFICATIONS 9. WARRANTY APPENDIX I APPENDIX II Awilco Energysystem ES-2002...
  • Page 4: Important Safety Information

    DANGER: SHOCK HAZARD. KEEP AWAY This section contains important safety informa- FROM CHILDREN. FAILURE TO FOLLOW tion for the ES-2002 Powerpack. Each time, be- THESE INSTRUCTIONS CAN RESULT IN fore using the unit, READ ALL instructions and DEATH OR SERIOUS INJURY cautionary markings on or provided with the unit, and all appropriate sections of this guide.
  • Page 5 • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/ TV technician for help. Awilco Energysystem ES-2002...
  • Page 6: Introduction

    * Please contact authorized installer for proper INTRODUCTION connection to an engine alternator. Thank you for purchasing this AWILCO energy PRODUCT DESCRIPTION system. With our state of the art, easy to use design, this product will offer you reliable ser-...
  • Page 7: Installation

    Device’. Both terminals in the red connector are connected to battery positive (+), and both The built-in IMD in the ES-2002 complies with terminals in black connector are connected to the EN64557-8 standard. It is used to monitor battery negative (-). Please refer to tech spec the insulation resistance of the ES-2002 and to table for max allowed DC currents.
  • Page 8 Brackets can be inserted in 8 reverse connection (in order to transfer different positions around the cabinet. energy from the ES-2002 to vehicle battery), It is recommended to use all 4 brackets please make sure to use cables that can for secure installation of the ES-2002.
  • Page 9 • Plug the unit to an AC source. USING THE ANDERSSON CONNECTORS: • The LED on display will turn on. If AC input The ES-2002 allows for up to 200A continuous source is available, ”Status” LED turns discharge* Please use cables, red/black with green.
  • Page 10: Connecting To Bluetooth

    4. CONNECTING YOUR ENERGY SYSTEM TO BLUETOOTH: Every ES-2002 can be connected and 3. Under ”Devices” – find and choose your monitored by a smart phone/tablet via battery Bluetooth. However, the App only supports a. Trying to create new connection Android and iOS.
  • Page 11: Inverter/Charger Operation

    See more details on Inverter Setting. Amber: Battery (Inverter) Mode ”Display” LED is used to indicate the digital display function. Green: Display is showing Battery voltage in volts. Amber: Display is showing Output power in KW. (Continued on next page) Awilco Energysystem ES-2002...
  • Page 12 ”Select” button function: • Turns the inverter On/Off during • Check unit setting: Press once to Battery Mode. Press and hold for 1 check or verify unit”s present set second to turn the unit either ON functions or OFF. Awilco Energysystem ES-2002...
  • Page 13 A higher power system with bigger inverter surge power up to two times the rated output is required for these appliances. power, some high surge loads like sump- pumps, heavy duty motors etc. may still trigger Awilco Energysystem ES-2002...
  • Page 14: Feature Setting

    Li4 – Lithium Cb (Maximum current): Cb3 – Maximum Shore Power Current draw is 30A for 120V models and 16A for 230V models. FA (Fan Operation Setting) FA1 – Fan only activated when needed Fd (Factory default) Awilco Energysystem ES-2002...
  • Page 15 OFF, even with the AC Input power being present in By-pass mode. When the unit is turned off using the ”Power” button, the display remains ON showing the battery voltage and the ”Status” LED will turn off. (Continued on next page) Awilco Energysystem ES-2002...
  • Page 16 AC backup on the next AC blackout period. But if the inverter is turn OFF during the AC blackout period, next time when the there is an AC blackout again, the unit will not have automatically AC backup. 5A-55A Bulk/Float current setting: 5A/1.5A, 15A/3A, 35A/4A, 55A/6A. Awilco Energysystem ES-2002...
  • Page 17 11.8 Vdc Under voltage recovery: 12.6 Vdc ALARM SETTING Fault and warning audible alarm is disabled. Display panel only shows error code and audible alarm will not sound. Audible alarm will sound when fault or warning occurs. Awilco Energysystem ES-2002...
  • Page 18 <2Aac 55 Adc Use this setting when the shore power circuit breaker rating is 10A or higher >9Aac 5 Adc >7Aac and <9Aac 15 Adc >3Aac and <7Aac 35 Adc <3Aac 55 Adc (Continued on next page) Awilco Energysystem ES-2002...
  • Page 19 There is no fans slow-speed (they run at full speed when activated). This is the factory default setting. MANUFACTURING DEFAULT SETTING Reset all settings to manufacturing default settings (In1, AL1, SdL, Li4, Cb3, FA1 and maximum current setting for the charger) Awilco Energysystem ES-2002...
  • Page 20 • Press ”Select” button for 1 second to enter Individual Function Set Menu and you can make change to the settings. • The unit will EXIT the Main Menu automatically if ”Power” and ”Select” buttons are not triggered for more than 5 seconds. Awilco Energysystem ES-2002...
  • Page 21: Troubleshooting

    “Power” button is pressed once, the display and available. LEDs stay working for about 10 sec only. With this setting, the unit will provide AC Output Power only when the AC Input Power is available. Awilco Energysystem ES-2002...
  • Page 22: Specifications

    ANDERSON INPUT/OUTPUT PORTS Anderson Connector 1 120A when using only one pin / 240A when using both pins Anderson Connector 2 120A 120A Anderson Connector 3 120A when using only one pin / 240A when using both pins Awilco Energysystem ES-2002...
  • Page 23 Charging Voltage Range 14.6 VDC Float Voltage Range 13.8 VDC ±0.1 Charger Current (max) 55 ADC Charger Current Setting (A) 5,15,35,55 Battery Type Gel, Flooded, AGM, Fixed Charge Control Bulk/Absorption/Float Efficiency >80% BATTERY Type LiFePO4 Capacity 12V 100AH Awilco Energysystem ES-2002...
  • Page 24 Dimensions: H x W x D (front view) 320 mm x 339 mm x 384,5 mm OPTIONAL ACCESSORIES External Battery Bank AWILCO article LFP12100BM Anderson Connector Wire Assembly - Please refer to www.awilco.dk for options Insulation Monitor Bender ISO415R-2 Awilco Energysystem ES-2002...
  • Page 25: Warranty

    The limited warranty program is the only one connecting to improper polarity power sources. that applies to this unit, and it sets forth all the responsibilities of AWILCO ApS. There is no other warranty, other than those described herein. Any implied warranty of merchantability...
  • Page 26 If the unit is repaired, new or re- call our Customer Service Department at conditioned replacement parts may be used, at mail@awilco.dk or +45 56 56 54 00 for general manufacturer”s option. A unit may be replaced information if applicable.
  • Page 27 APPENDIX I Awilco Energysystem ES-2002...
  • Page 28: Appendix

    Dimensions: H x W x D (front view) 320 mm x operation, cycles quantity must not be less than 339 mm x 384,5 mm. 2000 cycles. See details on: www.awilco.dk INSTALLING THE UNIT WITH EXTERNAL ELECTRICAL FEATURES: BATTERIES (LFP12100BM) THROUGH...
  • Page 29 Otherwise, the battery will be damaged 2. Negative terminal – (Andersson BLACK or burned. connector) from battery 1 to battery 2. EXAMPLE OF 4 EXTERNAL BATTERIES CONNECTED IN PARALLEL: BATTERY 1 BATTERY 2 BATTERY 3 BATTERY 4 Awilco Energysystem ES-2002...
  • Page 30 Make sure the battery is fastened. Connection impedance < 0.1m. • Do not use the batteries in series. This will cause sparks, short circuit and destruction at the battery. Awilco Energysystem ES-2002...
  • Page 31 Awilco Energysystem ES-2002...

This manual is also suitable for:

Es-2002uk

Table of Contents