sec.3 SPECIFICATIONS
Display:
3.5 digit LCD, maximum
reading 1999
with function and decimal annunciators
Range
Selection:
Manual rotary switch
Overrange
Indication:
3 least significant digits blanked
Sampling Rate:
Approximately 3 times per second
Operating
Environment:
-10° to 50°C (14° to 122°F) at < 85%
Storage
relative humidity
Environment:
~— 20° to 60°C
(—4° to 140°F)
at
<
Ries
Temp. 90%
relative humidity
Coefficent:
Less than 0.07 = applicable accurac x
spec per deg C for temp -10° to 13°
and 33° to 50°F
Max. Conductor
Size:
2.16" (55 mm) diameter
Power Supply:
One AWS B-4, 9V transistor type battery
(NEDA #1604)
Battery Life:
400 hrs typical with carbon zinc cell,
DSA-2002
and
DSA-2002P;
16
hrs
typical
with
carbon = zinc
cell,
DSA-2003
Battery
Indicator:
"B"
symbol
appears
on
display
to
Dielectric
indicate low battery
Strength:
2500Vac for one minute
Dimensions:
9.7"H X 2.8" x 1.4"D (245 x 70 x 36mm)
Weight:
14.10z. (400g), DSA-2002/DSA-2002P
17.70z. (500g), DSA-2003
NOTE:
Current
readings
should
not
be
taken
on
conductors at a potential greater than 500Vac/dc above
ground potential during hand held operation.
|
RANGES
AC CURRENT (average responding, calibrated in RMS of a sinewave)
ACCURACY (50/60Hz*)
OVERLOAD
RESOLUTION!
DSA-2002/2002P
DSA-2003
PROTECTION
+(1.0% rdg + 2d)
(0-1500A)
+(2.5% rdg)
(1500-1999A)
*Accuracy for 40 to 1KHz:
multiply 50/60Hz accuracy by 2
+(1.5% rdg + 2d)
DC CURRENT (average responding)
ACCURACY
OVERLOAD
RESOLUTION | DSA-2002/2002P
DSA-2003
PROTECTION
| 01a
|
No Ranges
+(1.5% rdg + 2d)
3000A
[0008 [1
AC VOLTAGE
(average responding, calibrated in RMS of a sinewave)
ACCURACY (50/60 Hz**)
OVERLOAD
RESOLUTION | DSA-2002/2002P
DSA-2003
PROTECTION
| 200v_ [ow
|
+(1.0% rdg + 2d) | +(1.5% rdg + 2d)
:
:
| 08% 9 +20 |
**Accuracy for 40 to 1KHz: add 2d to 50/60Hz accuracy
DC VOLTAGE (average responding)
ACCURACY
RESOLUTION | DSA-2002/2002P
[ev
| cow _|
No Ranges
RESISTANCE
es
OVERLOAD
RESOLUTION|
DSA-2002/2002P
SA-2003
PROTECTION
DSA-2003
OVERLOAD
PROTECTION
+(1.5% rdg + 2d)
PEAK
HOLD
(DSA-2002P)
Peak hold display reads 1/./ 2 of peak current or peak voltage (RMS calibrated reading when a
sinusoidal AC current and voltage is measured).
a
Peak Response 10ms/100ms
Peak Hold Time Approximately
+1% of initial peak reading 1 minute after peak hold.
OUTPUT TERMINAL
(DSA-2003)
OUTPUT WAVE
OUTPUT
OVERLOAD
RESOLUTION
SHAPE
ACCURACY
PROTECTION
aA'
_ Same as
+1.5% rdg
input current
into load
S000AdG
O.1mMV/A
wave shape"
>100KQ
3000A peak
"Frequency response: DC to 1KHz (sinusoidal waveform)
NOTE: All accuracies are given for 13° to 33°C
All specifications subject to change without notice.
Need help?
Do you have a question about the AWS DIGISNAP DSA-2002 and is the answer not in the manual?