Guardian H980 - PureGuardian 1-Gallon 70-Hour Ultrasonic Cool Mist Humidifier Manual

Guardian H980 - PureGuardian 1-Gallon 70-Hour Ultrasonic Cool Mist Humidifier Manual

Advertisement

Guardian H980 - PureGuardian 1-Gallon 70-Hour Ultrasonic Cool Mist Humidifier Manual

SPECIFICATIONS

HUMIDIFYING MODE: Ultrasonic Cool Mist
TANK CAPACITY: 1.0 gallon
RUN TIME: Up to 70 hours on lowest mist setting.

PARTS

PARTS
SILVER CLEAN ™ TECHNOLOGY
Silver Clean ™ technology is embedded in the tank to fight the growth of mildew and mold on the surface of the water tank.

SET UP

Select a firm, level, flat location - at least six inches (15 cm) from any wall or object for proper air flow. Place the humidifier on a water-resistant surface, as water can damage furniture and some flooring. Do not place unit directly on carpet, towels, blankets or other absorbent surfaces. Guardian Technologies will not accept responsibility for damage caused by water spillage.

DIRECTIONS FOR USE

FILLING

Make sure unit is unplugged.

  1. Before first use, lift tank off base and remove tape from float arm. Remove the tank lid.
  1. Pour cool, clean water directly into the tank using a water pitcher. Fill to-max-line on Mist Tube.
  1. Return the tank lid.
  1. Add a few drops of your favorite essential oil to the pad in the tray. (Oil not included)


    DO NOT add oils or other additives directly into the water tank. Add only to the pad in the tray. Oils added to the tank will damage the tank and the whole unit. Any use of such additives in the tank will void the manufacturers warranty. Pureguardian essential oils and replacement pads sold separately at www.guardiantechnologies.com
  2. WATER REFILL INDICATOR
    When the unit is low on water the power button will blink until the unit is refilled or turned off. Simply add more water to continue use. Unit will automatically resume running when water tank has been refilled.

CONTROL OPERATION


Power Button
Before turning on make sure there is water in the unit. Press the Power Button.


Night light
Press once to turn on the 7 color night light. Continue to press up to 8 times to circulate through and select a color. The 9th press turns the light off. The nightlight can be used independently from the humidifier.


Mist Control Button
Speed 2 is the default speed when the unit is turned on.
Press Mist Control button to cycle through the speeds 1, 2 and 3.
Mist Levels:
1 = Orange
2 = Green
3 = White

GENERAL CLEANING

  1. Always unplug the unit before servicing in any way.
  2. Water tank. Remove the lid and empty the tank by pouring all the water out. Clean the inside of the tank with fresh water and a soft cloth or the cleaning brush.
  3. Outer surface of the unit. Wipe the lid and surface of the unit with a soft, damp cloth if needed. If you notice an accumulation of water during usage, reduce humidity and dry outer surface with a cloth.

DESCALING

  • Depending on usage and water type, cleaning to remove scale may be required weekly or every other week to optimize unit performance.
  • If you live in a hard water area, we recommend the use of distilled water for your humidifier. This will help reduce the precipitation of minerals or 'white dust'.
  • Do not clean the unit or water tank with detergents or cleaning chemicals of any kind.

ULTRASONIC DISK

  1. Unplug unit.
  2. Remove the lid and empty the tank by pouring all the water out. Remove the tank from base.
  3. Locate the ultrasonic disk on the inside center of the base unit.
  4. Use ONLY the enclosed cleaning brush to gently clean disk and remove build up and deposits.

Do not scrub or scrape the ultrasonic disk.

Ultrasonic Disk
Ultrasonic Disk
Clean the disk with the brush only. No other cleaning tool should be used. BRUSH ONLY.

If scale becomes difficult to remove with brush:

  1. Fill the tank with: mixture of 1 tsp. white vinegar and 1 tsp. water.
  2. Let solution stand for 5 minutes.
  3. With the vinegar in the tank, clean all interior surfaces with a soft cloth or brush to help remove scale.
  4. Also check mist nozzle and mist tube in water tank. Clean as needed.
  5. Rinse the tank thoroughly with water to remove scale and vinegar solution.

END OF SEASON STORAGE

  • Follow the Cleaning and Descaling instructions when the humidifier will be stored at the end of the season.
  • Dry the humidifier completely before storing. DO NOT store with water inside the Base or Water Tank.
  • Pack the unit in its original carton and store in a cool, dry location.

NOTE: IF YOU EXPERIENCE A PROBLEM DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE HUMIDIFIER OR PERSONAL INJURY.

TROUBLE SHOOTING GUIDE

PROBLEM SOLUTION
Water vapor and humidity are not produced.

Power Plug: Unplug and then try again.

Power Failure: When the power is returned, try again.

The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.

Air blows but water vapor is not produced.

Excessive Water: Empty the water in the base of the unit.

Detergent residue and/or oil ingredients from cosmetics, eta may be in tank; wash out tank and try again.

The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.

If you use hard water, replace with softer water.

Humidity level is low.

The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.

The water in the unit is too cold: Replace with cool, but not cold water.

Damage on the ultrasonic disk: Contact Customer Service

The humidity has a bad smell. Poor maintenance or dirty water: Clean the product thoroughly, and fill it with fresh water.
White dust is forming on nearby furniture. Hard water may deposit a certain amount of dust. Dust in the air also settles because of added humidity in the room. Use distilled water if this becomes a nuisance.
Unit has stopped working. No or low water. Unplug unit and refill tank.
Water is accumulating outside of unit or area surrounding unit.

Saturation of humidity. Lower mist control setting.

Unit not level and water is accumulating. Unplug and place on level surface. Point spray away from objects. Raise unit on a water-resistant level surface 2-3 feet off of floor.

Increased noise level.

Unit must be placed on a flat, level, hard surface.

Make sure it is NOT placed on a soft or absorbent surface.

Power button flashing red. Indicates low water. Unplug and refill tank.
Cannot smell aroma scent. Add a few more drops of oil to the aroma pad or replace aroma pad with a new one.

WARNINGS

Failure to comply with the warnings listed below may result in electric shock or serious injury.

warningThis product should be used only in accordance with the specifications outlined in this manual. Usage other than what has been specified here may result in serious injury.


  • To reduce the risk of severe burns, keep this product out of the reach of children and pets.
  • Disassembly, repair or remodeling by an unauthorized person may result in serious harm and will void the manufactures warranty.
  • Always place this humidifier on a firm, flat & level surface. This humidifier may not work properly on an uneven surface.
  • Do not place this product on cloth, carpet or an absorbent surface. This may block air inlet.
  • This product releases mist. Do not place this humidifier directly on wood furniture, flooring or any surfaces that could be damaged by water. Manufacturer does not accept any liability for damage in the case of the unit being placed incorrectly.
  • Do not use if the plug is damaged or loose.
  • Before filling or cleaning the unit, make sure it is unplugged.
  • Once the humidifier has been plugged in, do not tilt or move the unit.
  • Do not handle the plug with wet hands.
  • Do not excessively bend, twist, pull or damage the power cord.
  • Avoid placing this product where the humidity spout is pointed directly at an object or person.
  • Do not inhale the mist/vapor expelled from the product or drink water from the tank.
  • Do not fill the water tank with hot or boiling water.
  • Do not use this product in direct sunlight or near a heat source such as a stove, heater or radiator.
  • If the water tank becomes cracked or damaged, do not use.
  • Do not keep this product running for an extended period of time.
  • Unplug the cord when unit is not in use for an extended period of time and/or when no one is home.
  • Do not keep water in the tank when not in use for an extended period of time.
  • Do not clean the unit, water tank or water reservoir with detergents or chemicals of any kind.
  • The use of water additives in the tank including ethereal/essential oils, fragrances, eucalyptus, water conditioners, etc. will damage the appliance materials and as a consequence the whole unit. Any use of such additives in the tank will void the manufactures warranty.
  • Do not use this product near any other electronic device.
  • Do not cover the spray spout at any time during use. Do not put anything on or in the tank.

  • Neither humans nor animals can hear the high frequency vibrations.
  • When unplugging from outlet hold humidifier securely.
  • Do not place cord over objects.
  • Do not get water in or on the power cord or where it connects to the product.
  • Do not use near a sink.
  • Do not touch the water tank during operation.
  • Do not submerse the unit in water or pour water on the unit or in the humidity spout.
  • Do not cover the spout with cloth or hand and do not use without the spout.
  • Use clean or distilled water in tank. Hard water areas will require more frequent cleaning.

Stop using your humidifier and contact your physician if you have respiratory symptoms which you believe are associated with periods of use of your home humidifier, even if you are following maintenance directions.


Cancer and Reproductive Harm.
For more information go to www.P65Warnings.ca.gov.

Guardian Technologies LLC
26251 Bluestone Blvd.
Euclid, OH 44132
1.866.603.5900
www.guardiantechnologies.com

©2016 Guardian Technologies LLC E-8

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Guardian H980 - PureGuardian 1-Gallon 70-Hour Ultrasonic Cool Mist Humidifier Manual

Advertisement

Need Assistance?

Do you have a question about the H980 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents