AIR CONDITIONER FEATURES
ELECTRONIC CONTROL OPERATING INSTRUCTIONS
Before you begin, familiarize yourself with the control panel on the unit and the remote control as shown below and refer to the symbols for the functions you desire.
The unit can be controlled by either the unit controls or with the remote control.
![Magnavox - W-08CR - ELECTRONIC CONTROL OPERATING INSTRUCTIONS ELECTRONIC CONTROL OPERATING INSTRUCTIONS]()
UNIT CONTROL
NOTE: The following instructions represent the control panel on the unit, the same instructions can be used for the remote control.
TO TURN UNIT ON:
![Magnavox - W-08CR - TO TURN UNIT ON TO TURN UNIT ON]()
NOTE: (ON/OFF button)
The unit will initiate automatically the Energy Saver function under COOL, DRY, AUTO (only Auto-Cooling and Auto-Fan) modes.
DO THIS:
Press the ON/OFF button.
TO CHANGE TEMPERATURE SETTING:
![]()
NOTE:(LEFT/RIGHT button)
Press or hold either LEFT( <) or RIGHT (>) button until the desired temperature is shown on the display. This temperature will be automatically maintained anywhere between 62 F(17 C) and 86 F(30 C). If you want the display to read the actual room temperature, see To Operate on Fan Only section.
TO ADJUST FAN SPEEDS:
![Magnavox - W-08CR - TO ADJUST FAN SPEEDS TO ADJUST FAN SPEEDS]()
NOTE: (FAN button)
Used to select the Fan Speed in four steps-AUTO, LOW, MED or HIGH. Each time the button is pressed, the fan speed mode is shifted. For some models, the fan speed can not be adjusted in HEAT mode. On DRY mode, the fan speed is set to LOW automatically.
TO SELECT THE OPERATING MODE:
![Magnavox - W-08CR - TO SELECT THE OPERATING MODE TO SELECT THE OPERATING MODE]()
NOTE:(MODE button)
- To select mode, press the Mode button. Each time you press the button, the mode will chan ge based on the sequence from AUTO, COOL, DRY and FAN. The indicator light will show the m ode selected.
To operate on Auto feature:
- When you set the air conditioner to AUTO mode, it will automatically select cooling, heating (not available in Cooling-only models), or fan only operation depending on the temperature selected and the current room temperature.
- The air conditioner will adjust room temperature automatically to the approximate temperature point set.
- In this mode, the fan speed cannot be adjusted, as the fan speed is being controlled automatically.
To operate on Fan Only:
- Use this function only when cooling is not desired, such as for room air circulation or to exhaust stale air(only on some models). (Remember to open the vent during this function, but keep it closed during cooling for maximum cooling efficiency.) You ca n choose any fan speed you prefer.
- During this function, the display will show the actual room temperature, not the set temperature as in the cooling mode.
- In Fan only mode, the temperature is not adjusted.
To operate on DRY mode:
- In this mode, the air conditioner will generally operate as a dehumidifier. In a closed or sealed space, some degree of cooling will continue.
TO USE THE ENERGY SAVER FEATURE:
![Magnavox - W-08CR - TO USE THE ENERGY SAVER FEATURE TO USE THE ENERGY SAVER FEATURE]()
NOTE:(ENERGY SAVER button)
Press Energy Saver button to initiate this function. This function is available on COOL mode. The fan will continue to run for 3 minutes after the compressor shuts off. The fan then cycles on for 2 minutes at 10 minutes intervals until the room temperature is above the set temperature, at which time the compressor turns back on and cooling starts.
SLEEP FEATURE:
![Magnavox - W-08CR - SLEEP FEATURE SLEEP FEATURE]()
NOTE:(SLEEP button)
In this mode the selected temperature will increase by one degree, 30 minutes after the mode is selected. The temperature will then increase by another one degree after an additional 30 minutes. This new
temperature will be maintained for 6 hours before it returns to the originally selected temperature. This ends the Sleep mode and the unit will continue to operate as originally programmed. The Sleep mode program can be cancelled at any time during operation by pressing the SLEEP button again.
TIMER: AUTO START/STOP FEATURE:
![Magnavox - W-08CR - TIMER: AUTO START/STOP FEATURE TIMER: AUTO START/STOP FEATURE]()
NOTE:(TIMER button)
- Press the TIMER button, and the TIMER ON indicator light will illuminate to indicate that the AUTO START program is initiated.
- Press the TIMER button again to show the TIMER OFF indicator light which indicates that the AUTO STOP program is initiated.
- Press or hold the UP or DOWN button to change the timer duration by 30 minute increments, up to 10 hours then at 11 hour increments up to 24 hours. The contr wolill The control will count down the time remaining until start. The selected time will register in 5 seconds, and the system will automatically revert back to display the previo us temperature setting or room temperature when the unit is on.(when the unit is off, there is no display.)
- Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the Auto START/ STOP program.
CHECK FILTER FEATURE:
![Magnavox - W-08CR - CHECK FILTER FEATURE CHECK FILTER FEATURE]()
NOTE:(CHECK FILTER button)
This feature is a reminder to clean the Air Filter for more efficient operation. The LED (light) will illumi nate after 250 hours of operation. To reset after cleaning the filter, press the Check Filter button and the light will go off.
CLEAN AIR FEATURE: (only on some models)
![Magnavox - W-08CR - CLEAN AIR FEATURE CLEAN AIR FEATURE]()
NOTE:(CLEAN AIR button)
Press the CLEAN AIR button, the ion generator is energized and will help to remove pollen and im purities from the air, and trap them in the filter.
DISPLAYS:
![Magnavox - W-08CR - DISPLAYS DISPLAYS]()
DISPLAYS:
Shows the set temperature in OC or OF and the AUTO-TIMER settings. While in Fan olny mode, itonly mode, it shows the room temperature.
Error codes:
AS
- Room temperature sensor error.
Unplug the unit and plug it back in. lf error repeats, call for service.
NOTE:In Fan only mode, it will display LO or HI. - Evaporator temperature sensor error.
Unplug the unit and plug it back in. lf error repeats, call for service.
NOTE:
is displayed as shown in the left diagram.
HS
- Electric heating sensor error.
Unplug the unit and plug it back in. lf error repeats, call for service.
FOLLOW ME FEATURE:
(only on some models)
![Magnavox - W-08CR - FOLLOW ME FEATURE FOLLOW ME FEATURE]()
This feature can only be activated from the remote control. The remote control serves as a remote thermostat allowing for the precise temperature control at its location.
To activate the Follow Me feature, point the remote control towards the unit and press the Follow Me button. The remote display shows the actual temperature at its location. The remote control will send this signal to the air conditioner every 3 minutes interval until press the Follow Me button again. If the unit does not receive the Follow Me signal during any 7 minutes interval, the unit will keep to indicate the Follow Me mode has ended.
ADDITIONAL THINGS YOU SHOULD KNOW
Now that you have mastered the operating procedure, here are more features in your control that you should become familiar with.
- The Cool circuit has an automatic 3 minute time delayed start if the unit is turned off and on too abruptly. This prevents overheating of the compressor and possible circuit breaker tripping. The fan will continue to run during this time.
- The unit can show the temperature in Fahrenheit or Celsius.
To convert from one to the other, press and hold the LEFT and RIGHT TEMP/TIMER buttons at the same time, for 3 secondsю
Fresh Air Vent Control(on 10000~12000Btu/h models):
The Fresh Air Vent allows the air conditioner to:
- Recirculate inside air - Vent Closed (See Fig. A)
![]()
Fig. A (VENT CLOSED) - Draw fresh air into the room- Vent Open (see Fig. B)
![]()
Fig. B (VENT OPEN) - Exchange air from the room and draws fresh air into the room - Vent and Exhaust Open (see Fig. C)
![]()
Fig. C (VENT & EXHAUST OPEN)
Air Directional Louvers
![Magnavox - W-08CR - Air Directional Louvers Air Directional Louvers]()
The louvers will allow you to direct the air flow UP or DOWN(only on some models) and Left or Right DOWN (on some models) and Left or Right throughout the room as needed. Pivot horizontal louvers until they are in the preferred direction.
Move the Levers from side to side until the desired LEFT/RIGHT direction is obtained.
INSTALLATION INSTRUCTIONS
Your air conditioner is designed to be installed in standard double hung windows with opening widths of 23 to 36 inches(58.4cm to 91.4cm) (See Fig. D).
![]()
Lower sash must open sufficiently to allow a clear vertical opening of following size (see Table 1).Side louvers and the rear of the AC must have clear air space to allow enough airflow through the condenser, for heat removal. The rear of the unit must be outdoors, not inside a building or garage.
Model | 5000~8000Btu/h | 10000~12000Btu/h |
Size | 14 (35.6cm) | 15-1/2 (39.4cm) |
Table 1
NOTE: Save Carton and these Installation Instructions for future reference. The carton is the best way to store unit during winter or when not in use.
TOOLS NEEDED:
Phillips Screw Driver
Drill(If pilot holes are needed)
![]()
When handling unit, be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear coils.
NOTE: The top rail hardware and the following Fig. E, Fig. F and Fig. G are not applicable to units more than 10000Btu/h.
Before installing unit, the top rail must be attached on the unit (For <10000Btu/h models only).
Tool Needed: Phillips Screwdriver
- Remove the air conditioner from the carton and place on a flat surface.
- Remove top rail from the rear of the packaging material as shown in Fig. E.
![]()
- Align the hole in the top rail with those in the top of the unit as shown in Fig. F
![]()
- Secure the top rail to the unit with the 3/8 Screws as shown in Fig. G.
![]()
NOTE: For safety reasons, all four(4) screws MUST be securely fastened.
HOW TO INSTALL
NOTE: Top rail and Sliding Panels at each side are offset to provide the proper pitch to the rear of,, (5/16 ). This is necessary for proper condensed water utilization and drainage. If you are not using the Side Panels for any reason, this pitch to the rear must be maintained by other means.
- Place unit on floor, a bench or a table. There is a Left and Right side Filler Panels- be sure to use the proper panel for each side. When installed, the flange for securing the panel in place to the window sill will be facing into the room.
- Hold the side Panel in one hand and gently pull back the center to free the open end. See Fig.1.
![]()
- Slide the free end "
" section of the panel directly into the cabinet as shown in Fig. 2. Slide the panel down. Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet.
![Magnavox - W-08CR - HOW TO INSTALL - Step 1 HOW TO INSTALL - Step 1]()
- Once the panel has been installed on the side of the cabinet, make sure it sits securely inside the frame channel by making slight adjustments. Slide the top and bottom ends of the frame into the top and bottom rails of the cabinet. Fig.3.
![]()
- Slide the panel all the way in and repeat on the other side.
NOTE: If storm window blocks AC, see Fig. 10.
- Keep a firm grip on the air conditioner, carefully place the unit into the window opening so the bottom of the air conditioner frame is against the window sill (Fig.4). Carefully close the window behind the top rail of the unit.
![Magnavox - W-08CR - HOW TO INSTALL - Step 2 HOW TO INSTALL - Step 2]()
- Extend the side panels out against the window frame (Fig.5).
![Magnavox - W-08CR - HOW TO INSTALL - Step 3 HOW TO INSTALL - Step 3]()
- Place the frame lock between the frame extensions and the window sill as shown(Fig.6). Drive 3 / 4 (19mm)or 1" / 2 "(12.7mm) locking screws through the frame lock and into the sill.
![Magnavox - W-08CR - HOW TO INSTALL - Step 4 HOW TO INSTALL - Step 4]()
NOTE: To prevent window sill from splitting, drill 1 / 8" (3mm) pilot holes before driving screws. - Drive 3/4" (19mm) or 1/2" (12.7mm) locking screws through frame holes into window sash (Fig.7).
![Magnavox - W-08CR - HOW TO INSTALL - Step 5 HOW TO INSTALL - Step 5]()
- To secure lower sash in place, attach right angle sash lock with 3/4" (19mm) or 1/2" (12.7mm) screw as shown(Fig.8).
![Magnavox - W-08CR - HOW TO INSTALL - Step 6 HOW TO INSTALL - Step 6]()
- Cut Window sash seal foam and insert it in the space between the upper and lower sashes (Fig.9).
![Magnavox - W-08CR - HOW TO INSTALL - Step 7 HOW TO INSTALL - Step 7]()
If AC is Blocked by Storm Window
Add wood as shown in Fig.10, or remove storm window before air conditioner is installed.
![Magnavox - W-08CR - If AC is Blocked by Storm Window If AC is Blocked by Storm Window]()
If Storm Window Frame must remain, be sure the drain holes or slots are not caulked or painted shut. Accumulated Rain Water or Condensation must be allowed to drain out.
Removing AC From Window
- Turn AC off, and disconnect power cord.
- Remove sash seal from between windows, and unscrew safety sash lock.
- Remove screws installed through frame and framelock.
- Close (slide) side panels into frame.
- Keeping a firm grip on air conditioner, raise sash and carefully remove.
- Be carefully not to spill any remaining water while lifting unit from window. Store parts WITH air conditioner.
NOTE: After installing, make sure the air conditioner is tilted 3~4O to the outside to allow water drainagea ndp erfect cooling efficiency.
CLEANING AND MAINTENANCE
![]()
Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent shock or fire hazards.
![]()
Air Filter Cleaning
The air filter should be checked at least once a month to see if cleaning is necessary. Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils.
- Push the vent handle to the Vent Closed position (where applicable).
- Open the front panel.
- Grasp the filter by the center and pull up and out.
- Wash the filter using liquid dishwashing deter gent and warm water. Rinse filter thoroughly.
- Gently shake excess water from the filter. Be sure the filter is thoroughly dry before replacing.
- Or, instead of washing you may vacuum the filter clean.
Note: Never use hot water over 40C(104F) to cl ean th e ai r fil ter. Never attempt to operate the unit without the air filter.
Cabinet Cleaning
- Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry.
- Never use harsh cleaners, wax or polish on the cabinet front.
- Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the air conditioner.
Winter Storage
If you plan to store the air conditioner during the winter, remove it carefully from the window according to the installation instructions. Cover it with plastic or return it to the original carton.
TROUBLESHOOTING TIPS
Before calling for service, review this list. It may save you time and expense. This list includes common proble ms that may not be the result of defective workman-ship or materials in this appliance.
Troubleshooting section
Problem | Solution |
Air conditioner does not start | - Power cord may have been disconnected from the outlet. Push plug in firmly into the outlet.
- Fuse or circuit breaker may have been tripped. In this case, replace fuse with a time delay type or reset circuit breaker.
- Power button may be on OFF. Press the power button to turn ON.
- Current detection device (on some models only) on the power cord may have been tripped. Press the RESET button on the current detection device plug.
|
Air From unit does not feel cool enough | - If the room temperature is below 62F(17C), cooling may not begin until the temperature is higher.
- Temperature sensor element may be touching the cold coil, located behind the air filter. Straighten the tube away from the coil.
- The temperature may need to be set lower for the air conditioner to activate.
- The compressor may have been shut off by abrupt mode changes. Wait approximately 3 minutes and listen for compressor to restart when set in COOL mode.
|
Air conditioner is cooling, but room is still warm and ice seems to be forming on the cooling coils behind the AC casing | - The outdoor temperature of below 64F (18C)may be affecting operation. To defrost the coil, set the unit to FAN ONLY
- The air filter may be dirty. Clean the filter as instructed on the 'CARE AND CLEANING SECTION' of this manual.
- The temperature may be set too high. Set the temperature control to a lowering setting.
- Air directional louvers may be positioned improperly. Position louvers for better air distribution.
- The front of the unit may be obstructed by curtains, blinds, or other foreign bodies, restricting the air distribution. Clear the area around the front of AC unit.
- Cold air may be escaping the room through open doors, windows or openings. Close all open doors, windows, and other openings.
- In a warm room, a just activated air conditioner may need time to remove the heat present in the room and distribute cool air.
|
Air conditioner turns on and off rapidly | - A dirty air filter may be obstructing the cool air. Clean the filter as instructed on the 'CARE AND CLEANING SECTION' of this manual.
|
| - In cases where the outside temperature may be extremely high, set the FAN speed to a higher setting to circulate the air cool air better.
|
Noises coming from the unit when cooling | - This may be the operating sound of air movement and is normal. However, if the noise seems too loud, set the FAN to a lower speed setting.
- The noise may be due to window vibration. This can happen when the air conditioner is installed incorrectly. Refer to the installation instruction or check with the person who installed the unit initially.
|
Water dripping INDOORS when the unit is on COOL | - The air conditioner may have been improperly installed. Tilt the air conditioner slightly outward to allow water to drain out. Refer to installation instructions or check with the person who installed the unit initially.
|
Water dripping OUTSIDE when unit is cooling | - The unit may be accumulating a large quantity of moisture as it is dehumidifying a humid room. This is normal operation for excessively humid weather.
|
Remote control 'FOLLOW ME' mode deactivates prematurely (on some models only) | - Remote control may not be within range of the unit. Be sure to have the remote control within a 20 foot radius in front of the unit.
- The remote control signal may be obstructed. Remove any obstructions interfering with signal.
|
Room is too cold | - The temperature setting may be too low. Increase the temperature to a more comfortable level.
|
NORMAL OPERATING SOUNDS
![Magnavox - W-08CR - NORMAL OPERATING SOUNDS NORMAL OPERATING SOUNDS]()
High Pitched Chatter Sound High efficiency compressors may have a high pitched chatter during the cooling cycle.
Vibration Sound Unit may vibrate and make noise because of poor wall or window construction or incorrect installation.
Pinging or Switching Sound Droplets of water hitting condenser during normal operation may cause pinging or switching sounds.
Sound of Rushing Air At the front of the unit, you may hear the sound of rushing air being moved by t he fan.
Gurgle/Hiss Sound Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation.
All the illustrations in this manual are for explanation purpose only. Your air conditioner may ap
Read This Manual
Inside you will find many helpful tips on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the Troubleshooting Tips section.
![]()
- This appliance is not intended for use by children or persons with reduced physical, sensory or mental capabilities, unless they are supervised by a responsible adult or considered capable enough to operate the appliance safely.
- Children should be supervised to ensure that they do not play with the appliance.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- The appliance should be installed in accordance with national wiring regulations.
- Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
- The appliance with electric heater should not be operated near any combustible materials.
- Contact the authorised service technician for any repairs, maintenance, or have problems installing the unit.
NOTE: All the illustrations in this manual are for explanation purposes only.
Your air conditioner may appear to be slightly different.
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation may cause harm or damage. The seriousness is classified by the warning symbols below.
![]()
This symbol indicates the possibility of death or serious injury.
![]()
This symbol indicates the possibility of injury or damage to property.
Definition of symbols used in this manual are as shown below.
![Magnavox - W-08CR - Safety Precautions - Part 1 Safety Precautions - Part 1]()
![Magnavox - W-08CR - Safety Precautions - Part 2 Safety Precautions - Part 2]()
IMPORTANT SAFETY INSTRUCTIONS
NOTE For some models, the power cord for this air conditioner contains a current detection device designed to reduce the risk of fire. Please refer to the section Operation of Current Detection Device for details. In the event that the power cord is damaged, it cannot be repaired, it must be replaced with a cord from the Product Manufacturer.
![Magnavox - W-08CR - IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS]()
![]()
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
To avoid fire hazard or electric shock, do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord.
![]()
Electrical Information
- Be sure the power requirement is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the cabinet and behind the grille.
- Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
- Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.
- Ensure the receptacle is accessible after the unit installation.
- Do not run air conditioner without side protective cover in place. This could result in mechanical damage within the air conditioner.
Operation of Current Detection Device
(Applicable only to certain units with current detection device)
The power cord contains a current detection function that senses damage to the power cord. To test your power cord, do the following:
- Plug in the Air Conditioner.
- The power supply cord will have TWO buttons on the plug head. Press the TEST button, you will notice a click as the RESET button pops out.
- Press the RESET button, again you will notice a click as the button engages.
- The power supply cord is now supplying electricity to the unit. (On some products this it also indicated by a light on the plug head.)