The DCS.F2.N02.PA is a high-performance device designed for cleaning the ferrule end faces of LEMO's fiber optic
F2 contacts. Carefully read this instruction manual before using this device.
Please keep this instruction manual for future reference.
For use with LEMO F2 contacts such as:
FFS.F2.BA2.LCE30 (male contact)
PSS.F2.BA2.LCE30 (female contact)
FFT.F2.BA2.LCE10 (male contact field terminated)
These contact types are commonly used in the 3K.93C Series broadcast connectors (SMPTE connectors).
1. Safety precautions
Though our device is deemed safe, improper usage or handling can still inflict injury to others.
The DCS.F2.N02.PA is designed to clean ANSI/SMPTE (304 M-1009 and 311M-1998) based connectors, or other LEMO
connectors with F2 contacts.
LEMO is not liable for damage caused in attempt to apply this device to other applications.
2. Notes on usage
Do not attempt to disassemble as this can cause damage to the device.
Do not re-use cleaning cloth as this will eliminate its cleaning ability.
Do not touch the cleaning cloth as this will cause contamination.
Do not pull the cleaning cloth, use only the device body.
Do not use this cleaner when the cloth is empty, as this can cause damage to the connector.
3. Notes on storage for extended periods
Do not expose device to direct sunlight, high temperature or high humidity.
The cover on the guide cap should be closed at all times when device is not in use.
4. Device construction
Standard Mode
C. Lock Button
D.Outer Shell
F. Indicator
G. F2 Guide Cap male
DCS.F2.N02.PA Instruction Manual
Extended Mode
Push Lock Button
B. Nozzle
A. Tip
E. Cover
No
Part Name
A
Tip
Lead the cleaning cloth to the optical connector end face
B
Nozzle
Lead tip to the optical connector end face
C
Lock Button
Push the button to extend and contract the nozzle
D
Outer Shell
Push the outer shell to clean the connector
E
Cover
Avoids contamination of tip
F
Indicator
Provides indication of remaining cleaning cloth
G
F2 Guide Cap male
For use with F2 male contact
FFS.F2.BA2.LCT10 (male contact)
PSS.F2.BA2.LCT10 (female contact)
PST.F2.BA2.LCE10 (female contact field terminated)
Pull Nozzle
Function
Identification of remaining cloth
View of Indicator
Cloth
(White)
Full
Cloth
(White)
Little
Red
Red
Empty
View of the Nozzle end
Tip (Black)
Cloth (White)
Tip (Black)
No Cloth (Black)