Page 1
Original User Manual Touch IndustrialsPC VESA 12.1 OEM Christ Electronic Systems GmbH Alpenstraße 34 87700 Memmingen 11/2023 www.christ-es.com...
Page 2
Instruction Manual: Touch Industrial PC VESA 12.1 OEM Identification Product description 2.1 System Overview 2.2 Housing Description Hardware 3.1 External Interfaces Mounting 4.1 Torque 4.2 Mounting 4.2.1 Dismounting the cover plate 4.2.2 Mounting the cover plate 4.2.3 Replacing the cable grommets Commissioning 5.1 Function of the power button...
Page 3
Instruction Manual: Touch Industrial PC VESA 12.1 OEM 8.5 Temperature test Standards and Approvals 9.1 CE Marking 9.2 UKCA Marking 9.3 RoHS 9.4 Electromagnetic Compatibility 9.5 FCC Approval 9.6 Environmentally Appropriate Disposal Technical Support 10.1 Device Seal Doc. No.: PA10013282 3 / 32 Nov.
• Medical equipment for life support Technical changes Christ Electronic Systems GmbH reserves the right to change the information, designs and technical data contained in this documentation without prior notice. History The following editions of the manual have already been published:...
Page 5
Instruction Manual: Touch Industrial PC VESA 12.1 OEM Design of safety instructions The general structure of the safety instructions is shown below: NOTICE Type of hazard and source of hazard Consequences in the event of non-compliance with the guideline ➢ Measures to avoid hazards...
Instruction Manual: Touch Industrial PC VESA 12.1 OEM Product description System Overview Intel® Celeron™ 3965U 2.2 GHz Graphic Intel® HD Graphics 610 Memory 4 GB DDR4 Mass Storage 64 GB 3D TLC SSD BIOS AMI Optio 5 BIOS Interfaces 1 x M8 3-pin male connector A coded, Power; M8 4-pin male connector A coded, Power / CAN-IN 2 x USB Host 3.0 (Type A), X33, X34...
Instruction Manual: Touch Industrial PC VESA 12.1 OEM Description Hardware The description of the hardware refers to the device interfaces and the possible extensions for the device. External Interfaces NOTICE External cable for Power Supply Malfunction occur ➢ Prepare a proper earth connection on the power supply...
Instruction Manual: Touch Industrial PC VESA 12.1 OEM USB Host 3.0 (Type A) Function Description VBUS USB VCC USB Data- USB Data+ USB Ground StdA_SSRX- SuperSpeed transmitter differential pair StdA_SSRX+ SuperSpeed transmitter differential pair GND_DRAIN Ground for signal return StdA_SSTX-...
Instruction Manual: Touch Industrial PC VESA 12.1 OEM M8 4-pin male connector Function Description 24 V (max. 4 24 V (maximum 4 ampere) CAN_H CAN High Ground CAN_L CAN Low Table 10: Pinout M8 4-pin male connector M8 4-pin female connector...
Page 13
Instruction Manual: Touch Industrial PC VESA 12.1 OEM Mounting This chapter describes all the steps for assembly. The following warnings are safety instructions that must be applied throughout the assembly chapter and in every other life cycle of the de- vice.
Page 14
Instruction Manual: Touch Industrial PC VESA 12.1 OEM Mounting Step 1: Completely unscrew all four nuts on the back of the device. Illustration 5: Mounting Step 2: Push the threaded bolts through an assembly jig. Step 3: Screw all four nuts back onto the threaded bolts. The tightening torque is determined by the customer.
Page 15
Instruction Manual: Touch Industrial PC VESA 12.1 OEM 4.2.1 Dismounting the cover plate The cover plate can only be dismounted if it is not blocked. Step 1: Loosen all six screws marked in blue on the back of the device and store them together with the serrated lock washer.
Page 16
Instruction Manual: Touch Industrial PC VESA 12.1 OEM 4.2.3 Replacing the cable grommets Suitable cable grommets can be found on the icotek homepage: https://www.ico- tek.com/en/products/cable-grommets/qt If additional cables are routed out of the enclosure from the concealed interfaces, the cable grommets must be removed and replaced with suitable cable grommets for the corresponding cable diameters.
Page 17
Instruction Manual: Touch Industrial PC VESA 12.1 OEM Commissioning To put the device into operation, connect the power supply to the unit. The device starts. Further steps for commissioning are not necessary. Function of the power button If the device has a power button, it behaves according to the following standard.
Instruction Manual: Touch Industrial PC VESA 12.1 OEM Software The Software chapter describes settings and functions that may be required to use the device. BIOS Basic Settings AMI BIOS ROM has built-in settings program that allows users to make basic settings. This in- formation is stored in a battery supported CMOS RAM, so it remains stored even when there is no power supply.
Page 19
Instruction Manual: Touch Industrial PC VESA 12.1 OEM The following default settings are already made in the BIOS. LVDS Configuration Illustration 11: BIOS LVDS Configuration Setting Attempt Secure Boot Secure Boot is activated in this BIOS. This means that only signed images can be started.
Page 20
Instruction Manual: Touch Industrial PC VESA 12.1 OEM Installed Keys for the Secure Boot Illustration 13: BIOS Keys for the Secure Boot Settings in the Boot tab Illustration 14: BIOS Boot 6.1.2 Set Boot Priority If you want to boot from a USB device, the following settings must be made in the BIOS: 1.
Page 21
Instruction Manual: Touch Industrial PC VESA 12.1 OEM BIOS Update 6.2.1 Preparation Copy the AMI BIOS update files to a USB stick You can obtain the required files from Christ Electronic Systems. These are the same for Argon and Titanium. • •...
Page 22
➢ ESD protection must be observed. Do not touch any electronic compo- nents unnecessarily. Note: Within the warranty period, the battery may only be replaced by Christ Electronic Sys- tems GmbH. Note: Christ Electronic Systems GmbH will not bear any costs if the unit is damaged druing battery replacement. Description CR2450...
Page 23
Instruction Manual: Touch Industrial PC VESA 12.1 OEM Loosen all 12 countersunk screws M3 x 6 and store them. Illustration 17: Loosen screws of the front unit Remove the front unit. Do not disconnect any cables. Illustration 18: Remove the front unit Disconnect the battery.
Page 24
Instruction Manual: Touch Industrial PC VESA 12.1 OEM Loosen the cylinder screw M3 x 6 and remove the battery. Illustration 19: Replace battery Insert the new battery and screw it back on with the previously loosened screw. Replace the front unit and fasten it again with the 12 stored screws.
Instruction Manual: Touch Industrial PC VESA 12.1 OEM Technical Data This chapter summarizes the technical data. Mechanical Specifications Housing Aluminium Weight ca. 2.7 kg Dimensions 312 mm x 214 mm x 70 mm Mounting VESA MIS-D, 75 Cooling Passive Table 13: Mechanical Specifications...
Instruction Manual: Touch Industrial PC VESA 12.1 OEM Standards and Approvals The device meets the following requirements. CE Marking The device has been tested in accordance with the applica- ble EU directives and the associated harmonized stand- ards. UKCA Marking...
Page 28
Instruction Manual: Touch Industrial PC VESA 12.1 OEM FCC Approval The device meets the requirements of FCC for approval in the USA and Canada. This has been tested and confirmed by SGS. FCC (Federal Communications Commission) The device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause any harmful interference.
Page 29
Disposal of batteries: Batteries must not be disposed of with household waste at the end of their service life. Ask your local authority for information on how to proceed. Batteries used at Christ meet the require- ments of the Regulation (EU) 2023/1542.
Page 30
10.1 Device Seal A device seal is affixed to every Christ device in order to prove whether the device has been opened by a third party. In case of a defect, please do not open the device, but contact our service department.
Page 31
Touch Industrial PC VESA 12.1 OEM Instruction Manual Index of Illustration Illustration 1: Front Illustration 2: Rear Illustration 3: Dimensions Illustration 4: Dimensions Rear Illustration 5: Mounting Illustration 6: Dismounting the cover plate Illustration 7: Mounting the cover plate Illustration 8: Replacing the cable grommets...
Touch Industrial PC VESA 12.1 OEM Instruction Manual Index of Tables Table 1: History Table 2: System overview Table 3: Dimensions Table 4: Pinout USB 2.0 Table 5: Pinout USB 3.0 Table 6: Pinout Ethernet Gigabit Table 7: Pinout Serial Connector Titanium...
Need help?
Do you have a question about the VESA 12.1 OEM and is the answer not in the manual?
Questions and answers