CAMDEN WC13 Series Installation Instructions Manual page 3

Restroom control

Advertisement

WC13 SERIES RESTROOM CONTROL
IN S TA LLAT I ON I N S T R U C T I O N S
SURFACE MOUNT RESTROOM INSTALLATION
1. Place the white vinyl behind the surface aura enclosure and
place them against the mounting wall.
2. Use the #10 x 1'' pan head screws with the green pvc anchors
provided to hold the white vinyl and the aura enclosure against
the wall .
Note: White vinyl does not come with the CM-45/4 - 4 1/2"
'Push To Open'.
3. Place all the square rubber pads inside the flush aura enclosure.
Insert the aura board inside the flush aura enclosure, making
sure the screw holes on the aura board align with the screw
holes inside the surface aura enclosure. Use the #6 x 3/8"
self-tapping screws to tighten Aura board in place.
4. Place the Aura insert inside the surface aura enclosure, making
sure the mounting screw holes on the aura insert and the
surface aura enclosure align.
Note:
Use this drawing for the follow Restroom
Control Models:
1. CX-WC13XSM - Illuminated switch system
2. CX-WC13ASFM - Illuminated switch system
3. CX-WC13XSM & WEC-10 - Illuminated switch
and emergency call system
4. CX-WC13AXSM & WEC-10K2 - Illuminated switch
and emergency call system
#10x1'' Pan Head
screw (4pcs)
Aura Board
Aura Insert
self-tapping screw
6-32 Phillips
Screw (2pcs)
Plastic spacer
(For Use only on CM-2520/48)
Page 5 of 18
FOR CM-45/454SE1, CM-45/854SE1 & CM-45/4 SWITCHES
a. Use the 6-32 hex head screws to tighten the aura
insert slightly.
b. Fit in the assembled CM-45/4 by locating the screws
with the holes on the backplate.
c. Fit the hex key through the hole on the face plate and
completely tighten the 6-32 screws in place.
FOR CM-2520-4854SE1 COMBO SWITCH
a. Fit the plastic spacer inside the aura insert
b. Place the combo switch Inside the aura insert, making sure
the mounting holes on the aura and on the back plate align
c. Use the 6-32 Phillips screws to tighten in place.
5. Apply the label to the black vinyl as required.
White Vinyl
Note:
This Drawing should be used in addition
to each products respective Installation
Label
Manual (not in place of).
Surface
12 - 24 V
AC/DC
Aura Enclosure
Power
PUSH
TO
PUSH
LOCK
TO OPEN
5/8'' x 5/8''
PUSH
Square Rubber Pad
TO
(4pcs)
OPEN
#6x3/8'' Phillips
Outside Wall Switch
Inside
Inside 'Push-to-Lock'
(2pcs)
Wall Switch
CM-45/455SE1 (or similar)
CM-45/855SE1 (or similar)
(always unlocks
& opens door)
Active Color
Idle Color
Aura
Dip Switch
RED
1
1
RED
GREEN
2
2
GREEN
Settings
BLUE
3
3
BLUE
= Switch Position
FLUSH MOUNT RESTROOM INSTALLATION
1. Prepare the cut-out for the unit and fit in the dry wall bracket.
2. Slide in the black vinyl behind the flush aura enclosure and fit
them inside the dry wall bracket.
Note: Black vinyl does not come with the CM-45/4 - 4 1/2"
'Push To Open'.
3. Ensure the two mounting holes on the bracket and the Flush
aura enclosure align. Use the 8-32 phillips screws to completely
tighten in place.
4. Place the aura board inside the flush aura enclosure, making
sure the screw holes on the aura board align with the screw
holes inside the Flush aura enclosure. Use the #6 x 3/8"
self-tapping screws to tighten Aura board in place.
5. Place the Aura insert inside the Flush aura enclosure, making
sure the mounting screw holes on the aura insert and the flush
aura enclosure align.
Note:
LED 1
DISPLAY
0.0.7
Use this drawing for the follow Restroom
LED 2
CX-33
Control Models:
LED 3
1. CX-WC13XFM - Illuminated switch system
Relay 1
Relay 2
2. CX-WC13AXFM - Illuminated switch system
MENU
UP
DOWN
3.CX-WC13XFM & WEC-10 - Illuminated switch
and emergency call system
4. CX-WC13AXFM & WEC-10K2 - Illuminated switch
and emergency call system
+
12 / 24 VDC
Power
-
For Strike
Aura Insert
Magnetic
Contact
Switch
N.C.
Contacts closed
when Door
is closed
Wire MOV (supplied)
directly to strike
6-32 Phillips
CAMDEN DOOR CONTROLS
Screw (2pcs)
Enable
SCALE: NONE
DRAWN BY: DGW
1
REM/LOC
RELAY
2
WC-13 Washroom Package Wiring Diagram (normally unlocked)
SPEAKER
3
DRAWING No: DRG-CX - WC-13-7
FOR CM-45/455SE1, CM-45/855SE1 & CM-45/4 SWITCHES
a. Use the 6-32 hex head screws to tighten the aura
b. Fit in the assembled Push plate by locating the screws
c. Fit the hex key through the hole on the face plate and
FOR CM-2520-4855SE1 COMBO SWITCH
a. Fit the plastic spacer inside the aura insert
b. Place the combo switch Inside the aura insert, making sure
c. Use the 6-32 Phillips screws to tighten in place
7. Apply the label to the black vinyl as required.
Note:
This Drawing should be used in addition
to each products respective Installation
Manual (not in place of).
Black Vinyl
Relay 3
Label
Flush
Important:
Aura Enclosure
Ensure wiring polarity is consistent
from Relay 3 to each Aura Remote
Input terminals
8-32 x 1 1/2
Phillips Screw
(2pcs)
Door Operator
Aura Board
Fail-Safe Electric
Strike Shown
PUSH
(If Fail-Secure lock is used,
TO OPEN
wire to Terminals 1 & 2)
MOV
Outside Wall Switch
#6x3/8 Phillips
CM-45/455SE1 (or similar)
self-tapping screw
5502 Timberlea Blvd.
(2pcs)
Mississauga, Ontario
L4W 2T7
Aura
DATE : 03/07/17
REV: 2
Dip Switch
Settings
Plastic spacer
(For Use only on CM-2520/48)
= Switch Position
FILENAME :
WC-13-7 wiring diagram_R2
Part# 40-82D003
WC13 SERIES RESTROOM CONTROL
IN STA L LATIO N IN STR U C TIO N S
insert slightly.
with the holes on the backplate.
completely tighten the 6-32 screws in place.
the mounting holes on the aura and on the back plate align.
CX-33
Dry Wall
Bracket
12 - 24 V
AC/DC
Power
PUSH
TO
LOCK
PUSH
TO
OPEN
Inside
Inside 'Push-to-Lock'
Wall Switch
CM-45/855SE1 (or similar)
(always unlocks
& opens door)
Active Color
Idle Color
Enable
1
RED
1
RED
1
REM/LOC
GREEN
2
2
GREEN
2
RELAY
BLUE
SPEAKER
3
3
BLUE
3
Page 6 of 18
0
MENU
Con
wh
i
SCAL
D

Advertisement

loading