WC13 SERIES RESTROOM CONTROL
INS TA LL AT I ON I N S T RU CTI O N S
Note:
This Drawing should be used in addition
to each products respective Installation
Manual (not in place of).
PUSH
TO OPEN
Outside Wall Switch
CM-45/455SE1 (or similar)
Dip Switch
Settings
12 - 24 V
AC/DC
Power
PUSH
TO OPEN
Inside
Inside PUSH TO LOCK
Wall Switch
CM-45/855SE1 (or similar)
(always unlocks
and opens door)
Active Color
Idle Color
Aura
1
RED
1
GREEN
2
2
BLUE
3
3
= Switch Position
DISPLAY
0.0.8
CX-33
MENU
UP
Magnetic
Contact
Switch
Contact closed
when door is
closed
CM-450R/12
N/O N/C
3
3
1
PUSH
4
4
2
TO LOCK
Note: To unlock the door
in this mode an additional
NO contact block is required.
Camden Part# CM-4000/60N
Enable
SCALE: NONE
1
REM/LOC
RED
RELAY
GREEN
2
SPEAKER
BLUE
3
DRAWING No: DRG-CX-WC-13-8
LED 1
LED 2
LED 3
Relay 1
Relay 2
Relay 3
DOWN
+
12-24 VDC
Power for
-
Strike
N.C.
CM-AF501SO
BLK
BLK
CM-AF141SO
GRY
GRY
+V
-V
+24 VDC Power
Supply
CAMDEN DOOR CONTROLS
DRAWN BY: DGW
DATE: 03/08/17
CX-WC13FM & WEC10 Single Door Restroom (Normally locked)
FILE NAME: WC-13FM-8-WEC10 wiring diagram_R2
Important:
Ensure wiring polarity is consistent
from Relay 3 to each Aura Remote
Input terminals
Door Operative
Fail-Secure Electric
Strike Shown
(If Fail-Safe lock is
used, wire to Terminals
NC & COM)
Wire MOV
MOV
(supplied)
directly to strike
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
REV: 2
Part# 40-82D003
Page 16 of 18