  • Page 1 JREMO 10EX REMOTE CONTROL O&M MANUAL www.jeico.com...
  • Page 2 Act(s) of God, and so on; all such the defects shall be treated as in no warranty. JEICO® INDUSTRIAL REMOTE CONTROLLER MODEL JREMO 10EX JREMO 10EX Serial No.
  • Page 3: Table Of Contents

    …………… 1.1. COMMON SPECIFICATION ……………………………… 1.2 Transmitter (Tx) …………………………………………… 1.3 RECEIVER (Rx) ……………………………………………… 1.4 Model Suffixing …………………………………………… CHAPTER 2. JREMO 10EX Standard Set …………… 2-1 Standard set ……………………………………………… 2-2 CONTROL CONTACTS WIRE DIAGRAMS ……………… CHAPTER 3. INSTALLATION & FUNCTION SETTING ………...
  • Page 4 ▪ Do not try to copy, modify, or release this remote controllers without permis- sion in advance by JEICO, such an action is illegal. JREMO® series' remote controller have many international patents, certificates, and so on.
  • Page 5 JREMO 10EX Industrial radio remote controller PRECAUTIONS ▪ Without notice in advance and within JEICO's discretion this manual may be revised, added, and/or deleted for better use. B. GENERAL CAUTIONS ▪ Operator must be healthy both physically and mentally. ▪ Even though this remote controller is versatile, durable, and good for outdoor use try to avoid to contact directly by an excessive shock, pressure, wind, snow, rain, ices, or sunlight, high temperature, humid, gas, and etc.
  • Page 6: Chapter I. General Specifications

    : (Tx) IP55 / (Rx) IP66 - Case Construction : ANTISTATIC ABS 1.2 Transmitter (Tx) - Modle : JREMO 10EX - Batt. Power : 4 x 1.5 V Alkaline Batteries (LR6 AA Size) - Type : Single or Double Push Button Type - Size...
  • Page 7: Chapter 2. Jremo 10Ex Standard Set

    Industrial radio remote controller CHAPTER 2. JREMO 10EX Standard Set CHAPTER 2. JREMO 10EX Standard Set JREMO 10EX Standard Set comprises one transmitter and one receiver as following as a set 2-1 STANDARD SET A/B/C/D/M 90 x 215 x 105 mm 193 x 62 x 46 mm Approx.
  • Page 8: Control Contacts Wire Diagrams

    JREMO 10EX Industrial radio remote controller CHAPTER2. JREMO 10EX Standard Set 2-2 CONTROL CONTACT WIRE DIAGRAM ▪JREMO 10EX(10EX) A/B/C/D ▪JREMO 10EX M Single & Double P/B AC Diagram Single P/B DC Diagram JREMO 10EX A~D JREMO 10EX M RECEIVER RX3, 90 x 215 x 105 mm, approx. 1,350 gr.
  • Page 9 JREMO 10EX Industrial radio remote controller CHAPTER2. JREMO 10EX Standard Set ▪JREMO 10EX A+ ( a special JREMO 10EX suffix model) Standard Double P/B U/D Creep JREMO 10EX C Single P/B JREMO 10EX A 6 Double P/B JREMO 10EX A+...
  • Page 10: Chapter 3. Installation & Function Setting

    JREMO 10EX Industrial radio remote controller CHAPTER 3. INSTALLATION & FUNCTION SETTING CHAPTER 3. INSTALLATION & FUNCTION SETTING 3-1 CAUTIONS FOR INSTALLATION 1. Follow up all the safety rule of equipment (ex. crane) 2. Switch off the main power of equipment (ex. crane) in a first action.
  • Page 11: How To Install Jremo® Series Tx

    JREMO 10EX Industrial radio remote controller CHAPTER 3. INSTALLATION & FUNCTION SETTING 3-2 HOW TO INSTALL JREMO® SERIES TX 3-2-1. BATTERIES A. Insert 2 AA batteries at right position with + and -. An opposite position will cause an excessive heat to cause battery leakage, burning, and so on, any malfunction caused by such the poor batteries' handling will not be of free recovery no matter how long the guarantee period remained.
  • Page 12: How To Install Jremo® Series Rx

    3. Paring (Copying) from Rx to Tx done. 4. Unplug the connector and place the s/w to RUN position. D. Consult JEICO distributor and/or agent for further support. 3-3 HOW TO INSTALL JREMO® SERIES RX 3-3-1. PREPARATIONS A.
  • Page 13: How To Start & Use Password(Pwd)

    JREMO 10EX Industrial radio remote controller CHAPTER 3. INSTALLATION & FUNCTION SETTING 3-3-2. INSTALLATION SEQUENCE A. Power off equipment(ex. crane). B. To install receiver always try to use with the Rx Fixing Plate or Rx Fixing Bracket when applicable. C. Connect each wire end of receiver cable to a mating connector of equip- ment(ex.
  • Page 14: Chapter 4. Maintenance

    JREMO 10EX Industrial radio remote controller CHAPTER 4. MAINTENANCE CHAPTER 4. MAINTENANCE 4-1 STANDARD OPERATION A. Twist up the EMS button of Tx and do as START ON function procedure preset and find the Rx Main Lamp ON. During normal operation see if the Tx led shows Green light which is normal, and if the battery power of Tx goes weak then the Tx led light will turn to red and green color.
  • Page 15: Chapter 5. Troubleshooting

    JEICO takes a type of Led signaling error message for better, quick restoration in normal even at site.
  • Page 16 JREMO 10EX Industrial radio remote controller CHAPTER 5. TROUBLESHOOTING 5-3 Troubleshooting Appearances Causes Measures 1. Wrong Bat. Direction 1. Place in right pole direction Tx Led 2. Battery Consumed 2. Replace with new batteries No Signal & 3. Old Batteries 3.
  • Page 17: Appendix Ⅰ - 433 Band Frequency Table

    JREMO 10EX Industrial radio remote controller APPENDIX I : 433 BAND FREQUENCY TABLE APPENDIX I : 433 BAND FREQUENCY TABLE TOTAL NUMBERS : 70 CHANNELS Channel Spacing : 25 Kc CH. NO. CH. NO. 433.050 433.925 433.075 433.950 433.100 433.975 433.125...
  • Page 18: Appendix Ⅱ - 447 & 173 & 429 Frequency Table

    JREMO 10EX Industrial radio remote controller APPENDIX II : 447 & 173 & 429 FREQUENCY TABLE APPENDIX II : 447 & 173 & 429 FREQUENCY TABLE TOTATAL NUMBERS : 32 (447 Bands) / 35 (173 Bands) / 40 (429 Bands) CHANNELS Channel Spacing : 12.5Kc...
  • Page 19: Appendix Iii - Optional Accessories

    JREMO 10EX Industrial radio remote controller APPENDIX Ⅲ : OPTIONAL ACCESSORIES APPENDIX Ⅲ : OPTIONAL ACCESSORIES RAIN/DUST COVER Tx Hook MAGNET ANTENNA Rx Fixing Plate Rx Fixing Bracket Copier PC Gender & Software Full Cover Silicon & (Water & Oil free)
  • Page 20 J Building, 94-1, Choryang-ro, Dong-gu, Busan, 48805, Korea Tel. +82-51-818-7727 Fax. +82-51-804-2150 Email. jeicorp@kita.net www.jeico.com...