Download Print this page

Sony PS-1350 Service Manual page 3

Advertisement

PS-1350/PS-2350
PS-1350/PS-2350
1-4.
Tonearm Body Base Removal
auto-return
counterweight shaft
oe
tonearm bady
7
s
@©®P3x 16
[CAUTION]
rubber damper
Do
not remove
the tonearm
body
ass'y.
The reassembling of tonearm
body
will
result
in
mechanical
screw (A)
2.
Remove three hexagon-socket
Phono circuit board bracket
1, Remove
the auto-return
lever and
unsolder
five
lead wires.
2. Remove the arm lifter.
3. Remove the tonearm pipe shown below.
tonearm pipe
set screw
set screw
2.6x.3
screw (4) B26x6
4, Replace the tonearm pipe.
{Overhang Adjustment]
Install the alignment protractor
alignment protractor
:
on the turntable shaft.through
Bring the tonearm above the cross
point of two fine lines, and carefully
lower the stylus on the cross point.
fine line
,
el
lineorrect]
feorrect]
fineorrect]
Overhang is too fong
Overhang is too short.
(Slide the cartridge backward)
(Slide the cartridge forward}
tonearm pipe connector
tonearm body
counterweight shaft
1-6.
Turntable Shaft Removat
Pull out the turntable shaft by removing a screw
@ PSP 3 x 5.
turntable shaft
turntable
bearing
screw ® PSP3x 5
es
Note: Apply
grease on
the turntable
shaft,
when reinstalling it.
1-7.
Turntable Shaft Bearing Replacement
nut &
@ Place the turntable shaft bearing
by setting the hole of screw ta
the front.
@ After setting, apply
locking compound here.
Apply grease here.
shaft
:
q
(Part No. 7-662-001-1171}
turntable shaft bearing
3.
Remove the tonearm
body base.
tonearm body base
Adaptation to Local Line Frequency
Motor Pulleys
For60Hz
[Part No.
X-4844.007-1]
;
For 50 Hz
{Part No.
.
X-4844-007-2]
Procedure:
1. Install the replacement pulley, and set the speed
selector knob to 33 rpm position.
. Adjust the height, of the motor pulley so that the
top of motor pulley is even with the top edge of
i
speed selector lever as shown below.
,
speed selector
lever (33 rom}

Advertisement

loading

This manual is also suitable for:

Ps-2350