QuietClean_OM.gxd
3/5/09
10:00 AM
Pa
8
INSTALLING THE ODOR-LOCK™ PRE-FILTER(S) (HFD-112, HHT-217 AND HHT-219 ONLY) {continuen}
NOTE: If you choose to re-insert the standard washable pre-filter in lieu of the Odor-Lock™ pre-filter, they
are removed and inserted in the same way that the Odor-Lock™ filters are installed. They will not help
reduce odours but will be effective at capturing larger particles like dust, lint and pet fur.
REPLACING THE ULTRAVIOLET (UV) LAMPS (HHT-215, HHT-217, HHT-219)
The UV Reset LED light will illuminate when it is time to
replace the dual UV bulbs.
Be sure to turn off and unplug your air purifier.
Press the Filter Release button and remove the filter
assembly.
The UV bulb housing is on the left and has a finger
grip for ease of removal (Fig. 22). Gently remove the
UV bulb housing.
Turn the tab towards the unlock symbol (¢') (Fig 23).
Gently grasp the top of the tab and pull the bulb cartridge straight out of the UV
socket. Do not touch the bulb directly with your hands.
Do the same for the bottom tab and pull the bulb cartridge out of the UV socket.
Replace the top and lower UV bulb sockets.
The bulb cartridge will only fit one way; if it does not fit, turn the bulb cartridge
the other way (with the arrow pointing to the center of the unit} and insert.
Push down gently so that the bulb cartridge engages with the unit. Turn arrow to the lock position (6).
Place UV bulb housing back in air purifier housing and then insert ifD™ filter assembly.
With the air purifier powered on, press and hold the UV reset button (Fig. 24) until the
LED light goes out.
NOTE: Discard the old UV bulb cartridge at a household hazardous waste collection site.
Bulb and bulb housing are not intended for use with any other product or purpose.
Hg Lamp contains mercury. Manage in accordance with disposal laws.
See www.lamprecycle.org or cali 1-800-895-8842.
INSTALLING THE FILTERS (ALL MODELS)
Please make certain that the unit
is OFF and unplugged.
To install the ifD™ Filter and pre-filter:
+ insert the lower tab of the pre-tilter
frame into the filter assembly
de
(Fig. 25) and press the top tab into
er
the filter assembly until you hear
$
a "click" (Fig. 26).
* Align the filter assembly with the opening in the unit and insert back into the unit (Fig. 27).
Press until it is flush and you hear a "click,"