7. TEST EQUIPMENT REQUIRED FOR SERVICING
<
This table lists the test equipment required for servicing the Model PM-55 Stereo Amplifier.
-Distortion measurements
Distortion Analyzer
ACVTVM
Voltage measurements (AC)
,
OO
OO
S|
Oscilloscope
Waveform analysis.and trouble shooting and ASO aignment
Circuit Tester
Trouble shooting
.
é
DCVTVM
Voltage measurements (DC)
AC Wattmeter
Monitors primary power to amplifier
Line Voltmeter
Monitors potential of primary power to amplifier
Variable Autotransformer
Adjust level of primery power to amplifier
Shorting Plug
Shorts amplifier input to eliminate noise pickup
8. VOLTAGE CONVERSION
@ EUROPEAN
MODEL ONLY
;
To convert
the unit to a different
power
source
voltage,
change the position as illustrated in the drawing below.
VOLTAGE
SELECTOR
\
_
i
CAUTION
| DISCONNECT
POWER
SUPPLY
CORD
FROM
AC
OUTLET
BEFORE CONVERTING
VOLTAGE.