Hotpoint HDM67G0C2CX/U Quickmanual Installation page 14

Table of Contents

Advertisement

EN
GAS NOZZLE TABLE
GAS NOZZLE TABLE
GAS NOZZLE TABLE
GAS NOZZLE TABLE
GAS NOZZLE TABLE
haracteristics of the gas section
C C C
Model
HDM67G0C2CX/U
(1) The values in g/h refer to the capacities with liquid gas (Butane, Propane).
Table 1
Table 1
Table 1
Diameter
Burner
Triple Crown
(TC)
Semi Fast
(Medium)(S)
Auxiliary
(Small)(A)
Main Oven
Grill
Top Oven
Nominal (mbar)
Supply
Minimum (mbar)
Pressures
Maximum (mbar)
*
At 15°C and 1013 mbar - dry gas
**
Propane
The front right hob burner injector should be used as the pressure test point.
14
Gas category
II2H3+
By-Pass
Thermal Power
(mm)
kW (p.c.s.*)
Nominal Reduced
130
3.3
1.50
75
2.0
0.4
55
1.0
0.4
-
2.6
0.6
-
3.5
-
-
1.8
0.6
)
P.C.S. = 50,37 MJ/Kg
Gas section
Rated power
kW (1)
14,60 (G20)
14,40 (1047 g/h-G30)
(1028 g/h-G31)
Liquid Gas
Liquid Gas
Liquid Gas
Nozzle
1/100
1/100
(mm)
(mm)
***
236
63
2x65
145
30
69
73
30
50
77
36
167
-
96
247
30
65
138
28-30
20
35
***
Natural Gas
Natural Gas
Natural Gas
Flow*
Thermal Power
g/h
kW (p.c.s.*)
**
Nominal Reduced
232
3.3
1.50
143
2. 0
0.4
71
1.0
0.4
164
2.6
0.6
3.7
243
-
1.8
0.6
136
37
25
45
Butane P.C.S. = 49,47 MJ/Kg
Natural P. C.S. = 37,78 MJ/m3
Nozzle
Flow*
1/100
l/h
(mm)
2x99
309
104
190
78
95
120
248
150
352
(X)
104
171
20
17
25