Download Print this page
RDZ CORE CRONO TH User Sheet

RDZ CORE CRONO TH User Sheet

Advertisement

Quick Links

Wall-mounted touch device for detecting and controlling room
temperature and humidity (Comfort Index). Designed for the
management of the radiant system and connected Air Handling Unit.
HOME SCREEN
T
Key
Icon
User menu
T
Schedules
Technical menu
Informations
Settings
Date/Time (*)
Fancoil Setup (**)
Operative mode
T
The device is off
OFF
Away mode (*)
Schedule mode
Manual mode
Manual Temporary mode
(*) The icon appears only if the device is NOT connect to CoRe MCT or CoRe Connect.
(**) The icon is only visible if a fan coil is detected in the CoRe system.
STANDARD FUNCTIONS
From the operative mode "Manual mode", tap on the Set Temperature and set Comfort Index icons and adjust the values to your needs:
Key
summer
24 °C
SET
TEMPERATURE
winter
24 °C
SET COMFORT INDEX
CORE CRONO TH
USER SHEET
Dehumidification
Dew Point
24.0°
Description
By clicking on the Temperature icon it's possible to change the value by moving the slider between 16 °C
and 28 °C.
The setting is confirmed when the green LED light will be flashing 3 times, then the device will automatically
return to the Home screen.
It is only possible to change the Set Point with the Manual (
in the latter case the Temporary Manual operative mode will be activated (
26.0°
23.5°
By clicking on the Comfort Index icon, you can change the Set Point by moving the cursor between MIN
and MAX. The setting is confirmed when the green LED light flashing 3 times, then the device automatically
returns to the Home screen. It is possible to change the Set Point only when using the Manual operative
mode. (
) .
T
Temperature
T
• Set
• Detected Temperature
) or Programming (
18.0°
23.5°
Con rmation LED
Detected Index Comfort
Suf
Opt
Required Index Comfort
1 / 8
Model
Code
CoRe CRONO TH
6600153
Integration
Season/Antifreeze
Radiant system
Comfort Index
• Set
• Dected Comfort index
), operative modes;
) (see page 2 and page 6).
Con rmation LED
Detected temperature
Required temperature

Advertisement

loading
Need help?

Need help?

Do you have a question about the CORE CRONO TH and is the answer not in the manual?

Questions and answers

Summary of Contents for RDZ CORE CRONO TH

  • Page 1 CORE CRONO TH USER SHEET Wall-mounted touch device for detecting and controlling room Model Code temperature and humidity (Comfort Index). Designed for the CoRe CRONO TH 6600153 management of the radiant system and connected Air Handling Unit. HOME SCREEN Icon...
  • Page 2: Operative Mode

    USER SHEET OPERATIVE MODE At the first switch on, CoRe CRONO TH is set to OFF operative mode. Touch the button and select Programming or Manual operative modes to use the device. Description The device is switched off, but the Anti-Freeze function remains functional.
  • Page 3: Technical Menu

    Forced Dehumidification: On Forced activation of the dehumidification Pairing : pairing of CoRe CRONO Th to the smartphone to connect it to the app Advanced Cmd Hard reset : reset to factory settings, all configurations and programmes will be deleted Limit function Dew Point: On Limit set Dew Point: min.
  • Page 4 7 to 9 (called Local 7, Local 8 and Local 9) they can be customised for each device. To use the shared time bands, just define the settings on the first CoRe CRONO Th device, then these will be automatically communicated to the other terminals; now, simply enter in the Schedules menu of each device and do the activation.
  • Page 5 The diagram below represents an example of scheduling that will be active from Monday to Friday, with a daily time interval from 08:00 to 18:00; during this period, CoRe CRONO TH will maintain the temperature of 18 °C (Set Point).
  • Page 6 USER SHEET TEMPORARY MANUAL MODE OPERATING If the device is set in the Schedule operative mode, changing the Set Point directly from the cursor, the Temporary Manual operating mode is activated. With this function it is possible to regulate the temperature with a different Set Point for a pre-set time period, which is different from the time schedule active at that moment.
  • Page 7: General Summary

    USER SHEET GENERAL SUMMARY Icon Flashing light Dehumidification Integration • Not active • Not active User menu • Active • Cooled air supply • Schedules • Dew Point control ( • Heated air supply • Technical menu • Informations Season •...
  • Page 8 USER SHEET This document may be subject to change. Through the QR-Code you can check the latest available update. Manual changes are prohibited. CLICK | SCAN FAA0EC002BZ.00 09/2023 qr.rdz.it/?qr=P628 8 / 8...

This manual is also suitable for:

6600153