    Warning General Safety ● The appliance may only be installed and connected by licensed gas fitters authorized persons. ● Built-in appliances may only be used after they have built in to suitable built-in units and work surfaces that meet local authority standards. ●...
  • Page 3: Safety During Use

    ●The appliance is not intended for use by young children or infirm persons without supervision. ●Young children should be supervised to ensure that they do not play with the appliance. Safety During Use • There is the risk of burns from the appliance if used carelessly. •...
  • Page 4: How To Avoid Damage To The Appliance

    ● Risk of burns! Do not place objects made of metal, such as knives, forks, spoons and saucepan lids on the cooking surface, as they can get hot. Safety Instructions Safety When Installation ● DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLI ANCE.
  • Page 5: Safety When Cleaning

    Gas type label nearby the gas inlet, black color for natural gas, signal red color for ULPG. Natural Gas Universal LPG Refer to gas supplier if supply in doubt Refer to gas supplier if supply in doubt Product Description GH60SSC GH12SFC GH30SFC 1.Pan support 2.Burner 3.Knobs 4.Panel GH90SF Australia: United States: ozmyhomeappliances@gmail.com...
  • Page 6 Knob Total gas Model Burner supports position consumption NG: 13MJ/h Front GH12SFC With Cast Iron LPG:13MJ/h NG: 16.0MJ/h Front GH30SFC 1R+1SR With Cast Iron LPG: 16.1MJ/h LPG: 30.5MJ/h GH60SSC 1W+2SR+1A With Cast Iron Right NG: 29.5MJ/h LPG: 39.6MJ/h GH90SF 1W+2SR+1R+1A...
  • Page 7: Technical Specifications

    Product Cut-out Rated Electrical Dimensions Size Input Model weight Connection (h x w x d)mm (w x d)mm Power GH12SFC 100x290x500 266 x 478 5.64Kg 220-240V/50Hz 0.5W GH30SFC 100x290x500 266 x 478 5.32Kg 220-240V/50Hz 0.5W GH60SSC 100 x 580 x 500 220-240V/50Hz 0.5W...
  • Page 8 To Be Installed Only By An Authorized Person 1. Cupboard Cutting Gas Cooktop Gas Cooktop GH90SF GH12SFC/GH30SFC Gas Cooktop GH60SSC 2. Place Burner Box Apply the adhesive sealing tape to the underside lip of the burner box. Shown at G opposite.Place burner box into cutout hole and fit clamping brackets to clamp the hotplate to the bench.
  • Page 9 3. Fit Burners And Trivet Replace burners and ensure they are correctly repositioned over the ignitor and thermocouple. The ignitor must be clean for trouble free sparking. Test burner ignition and burner flame for correct operation, If burner is placed correctly it will not rotate on its supports .
  • Page 10 75℃ at any point along its length. After having installed the hotplate, the GPO must always be in an accessible position. Wiring diagram GH12SFC GH30SFC GH60SSC GH90SF 5. Gas Connection Install in accordance with relevant gas standards and/or codes of practice applicable.
  • Page 11 Ensure the supply connection point, test point and natural gas regulator adjustment screw (for Natural gas installation) are accessible for testing and/or adjustment with the hotplate in the installed position. Natural Gas Regulator Where a flexible hose assembly is used, ensure it is approved to AS/NZS 1869, Class B.
  • Page 12: Universal Lpg

    Universal LPG (the appliance test point is located at the injector) Gas pressure must be checked to confirm the appliance operating pressure is 2.75 kPa, the appliance test point is the rapid burner injector as shown below. 1. Disconnect power. 2.
  • Page 13 Adjusted For Ulpg 2.75KPa Adjusted For Natural Gas 1.0KPa Nozzles Nozzles Burner Diameter consumption Burner Diameter consumption type (mm) MJ/h type (mm) MJ/h 0.98 13.0 1.70 13.0 0.90 10.0 Rapid Rapid 1.40 10.0 Semi 1.10 Semi 0.70 Rapid Rapid Auxiliary 0.90 0.55 Auxiliary...
  • Page 14 17 13 For model GH90SF For model GH90SF Adjusted for natural gas 1.0KPa Adjusted for ULPG 2.75KPa Nozzles Nozzles Burner Burner Diameter consumption consumption Diameter type type (mm) (mm) MJ/h MJ/h 13.0 1.70 0.98 13.0 10.0 Rapid 1.40 10.0 Rapid 0.90 Semi Semi...
  • Page 15: Start Using Your Appliance

    17 14 Start Using Your Appliance GH12SFC GH30SFC GH60SSC GH90SF Description Explanation These show which zone is under control. Zone indicators Flame power of the zones, is the lowest and Flame power is the highest. Australia: United States: ozmyhomeappliances@gmail.com 1(844) 538-7890 www.gaslandchef.com.au...
  • Page 16 The cooktop are fitted with mains powered electronic spark ignitors, so must be connected to mains power supply (i.e. nominal 220~240 V ac) to operate. If power is not available, the cooktop will still work but the burners will have to be lit with a match or similar.
  • Page 17: Maintenance

    17 16 The minimum utensil (pan) diameters in millimeters (mm) for each burner are: Auxiliary (small) = 80 mm Semi-Rapid (medium) = 140 mm Rapid (large) and Triple ring (wok) = 195 mm For best efficiency and to ensure utensil handle does not overheat, place the utensil centrally on the burner and adjust the flame height so all the flame remains under the utensil.
  • Page 18: Troubleshooting

    Use a cotton bud, tooth brush, or some other item to clean out any incrustations or dirt from the four holes marked(H) The spark gas is 4-6mm. Replace burners and ensure they are correctly repositioned over the ignitor (S) and thermocouple (T). The ignitor (S) must be clean for trouble free sparking.
  • Page 19: Troubleshooting Table

    • Flame lighting back into the burner (normally associated with a popping sound). • Objectionable odour of the flames combustion products. Should a faulty condition develop in the cooktop that is not described above, refer to the following table first for possible causes and remedies prior to contacting an authorised service representative.
  • Page 20 Choose a suitable utensil. Flame tips are very Incorrect gas supply type or Check the gas supply type yellow incorrect gas regulator. andgas regulator if correct. For model GH12SFC/GH30SFC GH60SSC/GH90SF DO NOT REMOVE SAI-400366 SAI-400193 A S/NZ S5263.1.1 A S/NZ S5263.1.1 SAI GLOBAL...