Download Print this page

SC POWER SC120 Instruction Manual

Smart battery charger for agm, gel & conventional

Advertisement

Quick Links

THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS. PLEASE SAVE THESE
INSTRUCTIONS. KEEP WITH OR NEAR CHARGER AT ALL TIMES.
WARNING
1.
— RISK OF EXPLOSIVE GASES.
a.
Working in the vicinity of a lead-acid battery can be dangerous. Batteries generate explosive
gases during normal battery operation.
b.
For this reason, it is of the utmost importance that prior to each use of your charger, you read
and follow the instructions provided exactly
c.
The appliance is not intended for use by young children or infirm persons without
supervision. Young Children should be supervised to ensure that they do not play with the
appliance.
2.
To reduce risk of a battery explosion, follow these instructions and those marked on the battery.
3.
NEVER smoke or allow an open spark or flame in the vicinity of the battery or engine.
4.
CAUTION—To reduce the risk of injury, use the charger for charging a rechargeable lead-acid battery
only. It is not intended to supply power to a low-voltage electrical system or to charge dry-cell
batteries. Charging dry-cell batteries may cause them to burst and cause injury to persons and
damage to property.
5.
Do not expose the charger to moisture, rain or snow. For indoor use only.
6.
Use of an attachment not recommended or sold by the battery charger manufacturer may result in a
risk of fire, electric shock, or injury to persons.
7.
To reduce risk of damage to electric plug and cord, pull by plug rather than cord when disconnecting
the charger.
8.
Make sure cord is located so that it cannot be stepped on, tripped over, or otherwise subjected to
damage or stress.
9.
Study all the battery manufacturers' specific precautions such as removing or not removing cell caps
while charging and recommended rates of charge.
10.
Do not use the battery charger unless the battery voltage matches the output voltage rating of the
charger.
11.
Do not operate the charger in a closed-in area or restrict ventilation in any way.
12.
Do not operate the charger with damaged cord or plug. If the supply cord cannot be replaced and
the cord is damaged, the appliance should be scrapped.
13.
Do not operate the charger if it has received a sharp blow, been dropped, or otherwise damaged in
any way. Take it to a qualified repair station or local dealer.
14.
Do not disassemble the charger. Take it to a qualified repair station or local dealer when service or
repair is required. Incorrect reassembly may result in a risk of electric shock or fire.
15.
To reduce risk of electric shock, unplug the charger from an outlet before attempting any
maintenance or cleaning.
16.
This product is not intended for use by persons with physical or mental disabilities children and
persons with limited experience and knowledge, without supervision or instruction on the use of the
device through a person responsible for their safety.
17.
If the power cable is damaged, it must be replaced by the manufacturer, its after-sales service or
qualified persons to avoid danger.
18.
Connection
The charger must be connected to an earthed power supply.
INSTRUCTION MANUAL
SC120 SMART BATTERY CHARGER FOR
AGM, GEL & CONVENTIONAL
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the SC120 and is the answer not in the manual?

Questions and answers

Summary of Contents for SC POWER SC120

  • Page 1 INSTRUCTION MANUAL SC120 SMART BATTERY CHARGER FOR AGM, GEL & CONVENTIONAL THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS. PLEASE SAVE THESE INSTRUCTIONS. KEEP WITH OR NEAR CHARGER AT ALL TIMES. WARNING — RISK OF EXPLOSIVE GASES. Working in the vicinity of a lead-acid battery can be dangerous. Batteries generate explosive gases during normal battery operation.
  • Page 2 • The connection to the power supply must be carried out in compliance with national standards. • The appliance incorporates an earth connection for functional purposes only. Important notice: DO NOT use other DC output cords than the one supplied or use an extension cords as it could result in damage to the unit which will not be covered by warranty.
  • Page 3 Connect and disconnect DC output clips only after setting the charger switches to off position and removing AC cord from the electric outlet. Never allow clips to touch each other. Follow these steps when battery is installed in a vehicle. A spark near battery may cause a battery explosion.
  • Page 4 is charging. When the battery is fully charged, the indicating light will turn green and the charger will switch itself to a storage charge mode and will automatically monitor and maintain the battery at full charge. CABLE CONNECTIONS: Your new battery charger is equipped with two output leads, a red positive (+) lead, and a black negative (-) clip lead and a ring terminal cable.
  • Page 5: Light Indication

    SELECTION FOR BATTERY TYPE A.C. power is connected with the wall socket properly Press MODE button for battery charge mode selection before you connect the charger to the battery terminals. LED Signal Description 6V 3A 6V lead acid battery charge mode at 3A max.
  • Page 6 Battery is connected in reverse polarity, please check the battery connection(s) and correct reverse polarity condition. Make sure Red to “+” and Black to “-“ The battery is worm out or is possibly defective. Suggest replacing battery ASAP Battery Recovery processes will commence if the charger detects any charge acceptance problems.
  • Page 7 Lead Acid Battery Charging Mode Traditional Battery AGM, GEL & Conventional 9 Stage Charge for l2V Lead Acid Battery, Conditioning and Maintenance Process Map. 5 Stage Charge for 6V and 24V Lead Acid Battery, Conditioning and Maintenance Process Map except step 2 {Battery Rescue}...
  • Page 8 9 Stage Charge for l2V Lead Acid Battery, Conditioning and Maintenance Process Map. 5 Stage Charge for 6V and 24V Lead Acid Battery, Conditioning and Maintenance Process Map except step 2 Battery Rescue Qualification Phase: will not begin if battery is below 4 volts. Battery Rescue Phase: * will begin.
  • Page 9 Technical Specifications: Model: SC120 Input: Auto-switching 200V - 240VAC (220W) 50/60Hz Output: 6VDC 3A Max. 12VDC 3A/ 6A/ 12A Selectable 24VDC 3A/ 6A Selectable Overcharge Protection: Yes Short Circuit Protection: Yes Park Proof: Yes Overload Protection: Yes Reverse Polarity Protection: Yes...