Unit Nomenclature; Nameplate Engineering Data - York YCAS Installation Operation & Maintenance

Air-cooled liquid chillers
Table of Contents

Advertisement

OPTIONS MODEL NUMBER
16 17 18 19
POWER FIELD
X
X
: Standard Power Option
M D
: MP NF Disconnects
M B
: MP Circuit Breakers
S
D
: SP NF Disconnects
S
X
: SP TB
B
X
: SP Circuit Breaker
S
B
: SP TB w/ Separate System Circuit Breakers
D
B
: SP NF Disconnect w/ Separate System Circuit Breakers
: SP Supply w/ Separate Disconnect Switch
C
S
: SP w/ Separate Disconnect Switch
C
S
: Special Power Option
Q Q
C
: Control Circuit Power Terminal Strip (std)
Q
: Special Transformer Required
T
: Control Transformer Required
: No Option Required
X
: Special Quote
Q
MP = Multiple Point
SP = Single-Point
NF = Non-Fused
TB = Terminal Block
Ser. = Service
TS = Thermal Storage
Ind. Sys. Brkr. & L. Ext. Handles = Individual
System Breaker & Lockable External Handle
BASIC PART NUMBER
YCAS00693EC50YGA
1 2 3 4
5 6 7 8
BASE PRODUCT TYPE
NOMINAL CAPACITY
: YORK
Tons
Y
#
#
#
#
0693
: Chiller
C
0773
: Air-Cooled
A
0783
: Screw
S
0873
0953
1063
1093
1163
1263
20 21 22 23 24 25 26 27 28
CONTROLS FIELD
X
Q
X
T
C
B
Q
X
S
F
G
I
Q
X
Q
L
C
N
Q
X
Q
X
P
Q
X
O
Q
X
S
Q
9
10
11 12 13
UNIT DESIGNATOR
REFRIGERANT
VOLTAGE/STARTER
High-EfÞ ciency
: R-407C
E
B
Standard
S
C
: R-22
High Ambient
G
5
29 30 31 32 33 34 35 36 37
COMPRESSOR / PIPING FIELD
: No Option Required
NUM
: Special Quote
TS
QQ
: No BAS Reset / Offset Required
X
: Temp Reset / Offset
C
: Current Reset / Offset
S
: Both Temp and Current Reset / Offset
B
: Special BAS Reset / Offset Required
Q
X
: English LCD & Keypad Display (std)
Q
: Spanish LCD & Keypad Display
: French LCD & Keypad Display
: German LCD & Keypad Display
: Italian LCD & Keypad Display
: Special LCD & Keypad Display
: No Option Required
: Special Quote
: N. American Safety Code
: European Safety Code
: No Listing
: Special Safety Code
: No Option Required
: Special Quote
: No Pump Control Required
: Pump Control Required
: Special Pump Control Required
: No Remote Control Panel Required
: Optiview Remote Control Panel Required
: Special Remote Control Panel Required
: No Sequence Kit Required
: Sequence Kit Required
: Special Sequence Kit Required
14 15
DESIGN/DEVELOPMENT LEVEL (STYLE)
:
: Design Series G
G
:
: Engineering
A
:
Change
:
or PIN Level
0
: 380/3/50
:
: Wye (Star) Delta
Y
: Across-the-Line
X
: Leaving Water Temp = Degrees
: Thermal Storage
: Special LWT Requirements
: No Chicago Code Kit Required
: Chicago Code Kit Required
: Service Isolation Valve
: Both Isolation Valve and Chicago Code
: Special Chicago Code Kit Required
: Standard Valves Required
: Special Optional Valves Required
: No Option Required
X
: Special Quote
Q
: No Option Required
X
: Special Quote
Q
: No Option Required
X
Q
: Special Quote
X
: No Option Required
Q
: Special Quote
X
: No Option Required
Q
: Special Quote

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ycas0693ecYcas0953ecYcas1063ecYcas1263ec

Table of Contents