Electrostatic Discharge Immunity - Philips BDP2305/F7 Service Manual

Table of Contents

Advertisement

ETSI EN 301 489-17 v.2.1.1 (2009-05)for European countries
ETSI EN 300 328 v1.7.1 (2006-10)for European countries
In countries where EMC standards are not compulsorily enforced, CISPR22 must be enforced.

3.3 Electrostatic Discharge Immunity

Standard Reference: IEC61000-4-2:2001
The product shall withstand electrostatic discharges on all user accessible parts.
3.3.1
Contact Discharge
Voltage level
Level
General (kV)
1
0 – 2
2
>2 – 4
3
>4 – 5
4
>5 – 7
5
3.3.2
Air Discharge
Voltage level
Level
General (kV)
1
0 – 4
2
>4 – 8
3
>8 – 10
4
>10 – 15
5
3.4 Immunity to Mains Interference / Failure
The following testsareto be done in operation (On) mode while playing a Blu-ray Disc and in standby mode.
3.4.1
Electrical Fast Transient / Burst Immunity
Standard Reference: IEC61000-4-4:2004
Performance
Level 1 500V
Level 2 1000V
Level 3 1500V
Performance criteria:
Criteria A: Normal performance;
Criteria B: Temporary loss of function or degradation of performance which ceases after the disturbance
ceases, and from which the equipment under test recovers its normal performance, without operator
intervention;
Criteria C: Temporary loss of function or degradation of performance, the correction of which requires operator
intervention;
Criteria D: Loss of function or degradation of performance which is not recoverable, owning to damage to
hardware or software, or loss of data.
2-14
Voltage level
USA (kV)
0 – 3
No deviations allowed
>3 – 4
Short perceptible deviations allowed
>4 – 5
Normal recallable function changes allowed
Resets allowed (recallable via standby/on button). No
>5 – 7
hang-ups allowed.
>7 – 8
No component or mechanical damage allowed.
Voltage level
USA (kV)
0 – 6
No deviations allowed
>6 – 8
Short perceptible deviations allowed
>8 – 10
Normal recallable function changes allowed
Resets allowed (recallable via standby/on button). No
>10 – 15
hang-ups allowed.
>15 – 18
No component or mechanical damage allowed.
Requirement
Performance criteria A
Performance criteria B
Performance criteria C
Requirement
Requirement
Conditions
Polarity: positive / negative
Angle: Asynchronous
Test duration: 12 /step
Step duration: 5 sec