Hide thumbs Also See for FUE-M/S 75A:

Advertisement

Quick Links

FUE-M/S 75A
Model
Document
Issue
Version
Language
Operator's manual
Converter
FUE-M/S 75A
5100041411
05.2021
03
en

Advertisement

Table of Contents
loading

Summary of Contents for Wacker Neuson FUE-M/S 75A

  • Page 1 Operator's manual Converter FUE-M/S 75A Model FUE-M/S 75A 5100041411 Document Issue 05.2021 Version Language...
  • Page 2 Any breach of the statutory provisions, in particular the protection of copyright, will lead to civil and criminal prosecution. Wacker Neuson Produktion GmbH & Co. KG is constantly working on the improvement of its products as part of the technical further development. Therefore, we reserve the right to make changes to the illustrations and descriptions in this documentation without incurring any obligation to make changes to machines already delivered.
  • Page 3 CALIFORNIA Proposition 65 Warning CALIFORNIA Proposition 65 Warning WARNING The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. WARNING Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm.
  • Page 5: Table Of Contents

    Additional information ......................4     Target group .......................... 4     Explanation of symbols ......................4     Wacker Neuson contact person ..................... 5     Limitation of liability ........................ 5     Product identification of the machine ..................5    ...
  • Page 6: Preface

    This operator's manual is not a manual for extensive maintenance or repair work. Such work should be carried out by the Wacker Neuson service or by technically trained personnel. The Wacker Neuson machine should be operated and maintained in accordance with this operator's manual.
  • Page 7: Introduction

    The information contained in this manual is based on machines manufactured up to the time of printing. Wacker Neuson reserves the right to change this information without notice. The manufacturer shall immediately include any modifications or additions in this manual.
  • Page 8: Wacker Neuson Contact Person

    Supplementary information. Wacker Neuson contact person Depending on the country, the Wacker Neuson contact partner is a Wacker Neuson Service, a Wacker Neuson affiliate or a Wacker Neuson dealer. On the Internet at www.wackerneuson.com. The manufacturer's address can be found at the beginning of this manual.
  • Page 9: Safety

    Attachment of accessories that do not originate from Wacker Neuson.  Spare parts or accessories that originate from Wacker Neuson can be safely mounted. They can be found on the Internet at www.wackerneuson.com. For example, do not drill into the housing to attach signs. Water can enter into the housing and damage the equipment.
  • Page 10: Competence Of The Operating Personnel

    You can find more information in the chapter Troubleshooting. Spare parts, accessories Only use spare parts from Wacker Neuson or such spare parts that are comparable in the design system and quality of the original parts. Only use accessories from Wacker Neuson.
  • Page 11: Protective Equipment

    They are familiar with the necessary safety devices.  They are authorized to operate equipment and systems independently according to the  standards of safety engineering. They are appointed by the contractor or operator to work independently with the unit. ...
  • Page 12: Safety When Operating Electrical Equipment

    Obstacles in the work and traffic area.  Load-bearing capacity of the soil.  Necessary protection of the job site, especially for the public transport area.  Necessary protection of walls and ceilings.  Options available in the event of accidents. ...
  • Page 13: Maintenance

    Care and maintenance jobs may only be carried out insofar as it is described in this operator's manual. All other work must be taken over by a Wacker Neuson contact partner. You can find more information in the chapter Maintenance.
  • Page 14: Safety And Information Labels

    Safety and information labels There are labels on your unit that contain important information and safety instructions. Keep all labels legible.  Replace missing or illegible labels.  The item numbers on the labels can be found in the parts book. Item Label Description...
  • Page 15: Design And Function

    Design and function Standard package The equipment is delivered fully assembled and is ready for operation straight out of the box. The standard package includes: Converter  Operator's manual  Application The equipment may only be used for the operation of internal and external vibrators. The equipment is used for the conversion of construction site current into a current that can be used by the equipment to be connected.
  • Page 16: Components And Operator's Controls

    #2 Frequency controller*** Supply line with 16A CEE plug 400 V, 50 Hz #3 Green LED for temperature display Group switch (only with FUE-M/S 75A 6 CEE- 32A)** * Position left: FUE not giving off any voltage * Position right: FUE giving off voltage ** Group switch switches 3 outlets on and off The group switch is only used to switch the vibrator on and off.
  • Page 17: Transport

    Transport WARNING Improper handling may result in injury or serious material damage.  Read and observe all safety instructions in this operator's manual, see chapter Safety. Transporting the equipment 1. Pull the plug out of the outlet. 2. Disconnect all connected equipment from the converter. 3.
  • Page 18: Operation And Use

    Operation and use WARNING Improper handling may result in injury or serious material damage.  Read and observe all safety instructions in this operator's manual, see chapter Safety. Before commissioning The equipment is ready for operation out of the box. Check equipment Check the equipment and all components for damage.
  • Page 19: Switching Off The Converter

    The unit is switched on with a green on switch #4. The white LED lights up once the converter is ready for operation.  If the green LED #3 lights up, the temperature of the installed transformer is OK and the ...
  • Page 20: Maintenance

    Have damaged equipment repaired immediately.  Check all equipment parts and components for damage.  Have the damage fixed by your Wacker Neuson contact partner.  Clean equipment NOTICE Do not clean the equipment with high pressure or steam cleaners! 1.
  • Page 21: Troubleshooting

    (performance data) on the nameplate * Reduce the number of units * Have the unit repaired at Wacker Neuson. Additional information can be found on the Wacker Neuson home page. Only FUE M/S 75A 6CEE-32A. Fault...
  • Page 22: Disposal

    Disposal 11.1 Disposal of old electrical and electronic equipment Professional disposal of this machine avoids negative effects on human health and the environment, helps with the targeted treatment of pollutants and makes it possible to recycle valuable raw materials. For customers in EU countries This machine is subject to the European directive for old electrical and electronic equipment (Waste Electrical and Electronic Equipment (WEEE)), as well as the corresponding national laws.
  • Page 23: Technical Data

    Technical data FUE-M/S 75A Model 4CEE-32A 2CEE-63A 6CEE-32A Item number 5000108000 5000610194 5000107999 5000610409 Length x width x height 520 x 310 x 493.5 Operating weight (mass) 29.5 Mains rating (input) Input voltage 400-415 3~ Frequency 50 - 60 Input current...
  • Page 24: Glossary

    Glossary Class rating The class rating according to DIN EN 61140 identifies electrical machines in terms of safety measures for the prevention of an electric shock. There are four class ratings: Class rating Significance No special protection, other than the basic insulation. No grounded conductor.
  • Page 25 EU Declaration of Conformity Manufacturer Wied GmbH & Co. KG, Landerstall 4, D-74426 Bühlerzell This declaration of conformity is issued under the sole responsibility of the manufacturer. Product FUE-M/S 75A Product type Converter Function of product Conversion of voltage and frequency...

Table of Contents