Wacker Neuson FUE 5/042/200 Operator's Manual
Wacker Neuson FUE 5/042/200 Operator's Manual

Wacker Neuson FUE 5/042/200 Operator's Manual

Fue 5 series; fue 6 series

Advertisement

Operator's manual
Converter
FUE 5/...
FUE 6/...
FUE-M/S 75A
EN
5200006668
5
2
0
0
08
0811
0
0
6
6
6
8

Advertisement

Table of Contents
loading

Summary of Contents for Wacker Neuson FUE 5/042/200

  • Page 1 Operator's manual Converter FUE 5/... FUE 6/... FUE-M/S 75A 5200006668 0811...
  • Page 2 0109930en 08.2011 Manufacturer Wacker Neuson Produktion GmbH & Co. KG Preußenstraße 41 80809 München www.wackerneuson.com Tel.: +49-(0)89-354 02-0 Fax: +49-(0)89-354 02-390 Translation of the original operator's manual in German...
  • Page 3 Foreword This operator's manual contains information and procedures for the safe opera- tion and maintenance of your Wacker Neuson machine. In the interest of your own safety and to prevent accidents, you should carefully read through the safety information, familiarize yourself with it and observe it at all times.
  • Page 4: Table Of Contents

    Table Of Contents Safety information General instructions ................5 Operation ....................5 Safety checks ..................6 Maintenance ..................6 Transport ....................7 Maintenance checks ................7 Technical data Note Protective measures in conjunction with electronic inverters ....11 Class rating I (grounded conductor) ............11 Class rating III (protective low voltage) ..........12 Connecting the inverter Assembly .....................13 Turning on the inverter ................13...
  • Page 5: General Instructions

    Safety information Safety information for electronic frequency and voltage inverters General instructions 1.1.1 Inverters may only be worked on independently by persons who ∗ are at least 18 years of age, ∗ are physically and mentally fit for this job, ∗...
  • Page 6: Safety Checks

    Only use original spare parts. Alterations to this machine, incl. adjustments of the frequency set by the manufacturer may only be carried out with the express permission of Wacker Neuson. In case of non-observance, all liability shall be refused. 1.4.2 Disconnect the inverter from the electrical power supply system before carrying out maintenance and repair work.
  • Page 7: Transport

    Safety information 1.4.4 The green-yellow grounded conductor of the connecting cable must be longer so that it will not be torn off if the strain relief fails. If interrupted, it can cause fatal injury. After conducting repairs, check the grounded conductor for continuity.
  • Page 8: Technical Data

    Technical data Technical data FUE 5/042/200 FUE 5/115/200 FUE 5/250/200 Item no. 0008901 0008948 0008947 Length x Width x Height 520 x 310 x 493,5 (20.5 x 12.2 x 19.4) (in): Operating weight (mass) kg (lb): 29,5 (65) 32 (70.5)
  • Page 9 Technical data FUE 6/042/200 FUE 6/042/200 US Item no. 0610094 0610015 Length x Width x Height 520 x 310 x 493.5 (20.5 x 12.2 x 19.4) (in): Operating weight (mass) kg (lb): 29,5 (65) Power supply value (input) Input voltage 400 - 415 3~ 230 - 240 1~ Frequency...
  • Page 10 Technical data FUE-M/S 75A Item no. 0107999 0108000 0610194 Length x Width x Height mm (in): 520 x 310 x 493.5 (20.5 x 12.2 x 19.4) Operating weight (mass) kg (lb): 29.5 (65) Power supply value (input) Input voltage 400 - 415 3~ Frequency 50 - 60 Input current...
  • Page 11: Note

    Note Note Protective measures in conjunction with electronic inverters In addition to the protective measures, machines are divided into class ratings. The class ratings specify protective measures to be taken to prevent direct contact. A distinction is made between class ratings I, II and III.
  • Page 12: Class Rating Iii (Protective Low Voltage)

    Note Caution: Due to the high stray current levels of the interference filter, make sure that the inverter is only connected to one fault current protective switch. This will prevent the fault current protective switch from being triggered inadvertently. Class rating III (protective low voltage) Protective low voltage are rated voltages up to 50 V of AC current.
  • Page 13: Connecting The Inverter

    Connecting the inverter Assembly Assembly instructions for the version without plug receptacle 4.1.1 Danger of electrocution! Only a qualified electrician is permitted to assemble the plug and perform a safety check. Danger to life Observe the assembly instructions! Turning on the inverter Only for FUE 6/042/200 US: Plug the CEE plug into a suitable CEE plug receptacle (230 V, 50/ 4.2.1...
  • Page 14: Turning Off The Inverter

    Turning off the inverter The machine is turned off with the red Off button. ∗ Both LEDs go out. Testing the insulation monitor Only FUE 5/115/200 and FUE 5/250/200: The function of the insulation monitor can be tested with the touch button with control lamp: ∗...
  • Page 15: Fue 6/042/200 Us

    FUE 6/042/200 US Switch * for internal vibrator / external vibrator Frequency controller Green LED for temperature indicator On/Off button with white LED Reset button with red LED Power cable for 230 V ∗ Switched to the left: to operate the AR (external vibrator) - Frequency controller is activated ∗...
  • Page 16: Fue-M/S 75A

    FUE-M/S 75A Circuit breaker on/off * Frequency controller Green LED for temperature indicator On/Off button with white LED Power cable with 16 A CEE plug 400 V, 50 Hz Group switch (only for M/S 75A with 6 plug receptacles)** * Switched to the left: FUE does not output voltage * Switched to the right: FUE outputs voltage ** Each group switch switches 3 plug receptacles on and off Note:...
  • Page 17: Malfunctions

    * Reduce the number of machines Have machine repaired by Wacker Neuson Service, your Wacker Neuson subsidiary or your Wacker Neuson dealer. Addresses can be found on the Wacker Neuson homepage. T01066GB.fm...
  • Page 18 FUE M/S 75A with 6 plug receptacles Malfunction Cause Remedy FUE is working Group switches are Switch group switches on Connected machines do switched off not work T01066GB.fm...
  • Page 19: Ec Declaration Of Conformity

    EC Declaration of Conformity Manufacturer Wacker Neuson Produktion GmbH & Co. KG, Preußenstraße 41, 80809 München Product Product Product category Inverter Product function Voltage and frequency conversion Item number 0007978, 0007979, 0008901, 0008947, 0008948, 0008949, 0008950, 0108479, 0107999, 0108000, 0610015, 0610019,...
  • Page 22 Wacker Neuson Production Americas LLC, N92W15000 Anthony Ave., Menomonee Falls, WI. 53051 Tel.: (262) 255-0500 Fax: (262) 255-0550 Tel.: (800) 770-0957 Wacker Neuson Limited - Room 1701–03 & 1717–20, 17/F. Tower 1, Grand Century Place, 193 Prince Edward Road West, Mongkok, Kowloon, Hongkong. Tel: (852) 3605 5360, Fax: (852) 2758 0032...

Table of Contents