en Installation instructions
Clip the gas pressure dampers onto the left- and
8.
right-hand side of the glass panel.
Insert the plug.
9.
Ensure that the plug engages with a click.
Plug connection to the glass plate
Insert the protective hose into the opening provided
10.
for it.
20
Insert the grease filters.
11.
Connect the appliance to the power supply.
12.
Piping
Note: If you are using an aluminium pipe, smooth the
connection area beforehand.
We recommend piping with an exhaust air pipe dia-
meter of 150 mm.
If the diameter of the air extraction ducting is less than
150 mm, you need a separately available reduction fit-
ting.
Establishing the exhaust air connection (exhaust
pipe, 150 mm diameter)
Secure the exhaust pipe to the air pipe connector.
1.
Establish the connection to the exhaust air opening.
2.
Seal the joints.
3.
Installing the flue duct
WARNING ‒ Risk of injury!
Components inside the appliance may have sharp
edges.
Wear protective gloves.
WARNING ‒ Risk of electric shock!
Sharp-edged components inside the appliance may
damage the connecting cable.
Do not kink or trap the connecting cable.
To separate the flue ducts, remove the adhesive
1.
tape or the flue duct from the protective packaging.
Remove any protective foil from both flue ducts.
2.
Use the 2 screws to screw the upper flue duct to
3.
the sides of the retaining bracket.
Note: To prevent scratches, lay soft towels over the
4.
edges of the outer flue duct to protect the surface.
Place the lower flue duct on the appliance and pull
it slightly apart.