Yolink YS7707-UC Installation And User Manual

Contact sensor

Advertisement

Quick Links

Contact Sensor
(Indoor/Outdoor)
YS7707-UC
Installa on & User Guide
Rev 1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the YS7707-UC and is the answer not in the manual?

Questions and answers

Summary of Contents for Yolink YS7707-UC

  • Page 1 Contact Sensor (Indoor/Outdoor) YS7707-UC Installa on & User Guide Rev 1.0...
  • Page 2: Table Of Contents

    ····· ···················································· · · · ·· · ·1 Introduc on ······························································································2 Set Up ·······································································································5 Installa on ································································································7 Using the YoLink App ················································································13 About YoLink Control ················································································18 Maintenance ···························································································24 Specifica ons ··························································································27 Troubleshoo ng ······················································································29 Warning ··································································································30 Customer Service & Warranty ···································································32...
  • Page 3: In The Box

    In the Box A. Contact Sensor (with Reed Switch) B. Magnet C. AA Ba ery (2) D. Self-tapping Screw (M3) (4) E. Double-sided Tape F. Quick Start Guide...
  • Page 4: Introduc

    The opened/closed status will be displayed on the YoLink app, and the status may be used as a trigger for custom automa ons (for example, turn on a light when a door is opened), as well as to ini ate smartphone alerts and no fica ons based on your preferences.
  • Page 5 Enclosure Clamp latch Houses two AA non-rechargeable ba eries * Due to the waterproof design, the enclosure clamp Latch may be slightly difficult to open Contact Sensor SET Bu on (Status LED) Moun ng Slot Antenna (the Shortest Wire) * Use screws to mount the magnet on the wall * Avoid to be cut or nicked Connec on Cable...
  • Page 6 Alert Mode (Door is Opened or Closed) Blinking Green Connec ng to Cloud Fast Blinking Green Establishing Connec on with YoLink System (YoLink Control) Slow Blinking Green Upda ng Fast Blinking Red Removing Connec on to YoLink System (YoLink Control)
  • Page 7: Set

    Set Up Follow the steps below to set up your Contact Sensor via the YoLink app Set Up - First-Time YoLink Users (Exis ng users proceed to Add Device, next page) * Get ready: To set up and use your Contact Sensor, you will need an Apple iPhone or tablet that is iOS 9.0 or higher, or an Android phone or...
  • Page 8 Add Device With a li ing/prying ac on on the two clamp latches, open the cover on the sensor Tap “ ” bu on, then scan QR Code on the device Press the SET bu on (on front of sensor) once a er installing the ba eries, the Status LED will blink several mes (red, then green).
  • Page 9: Installa

    Avoid interference, install the ontact sensor away from any strong magne c object Please add the Contact Sensor to the YoLink app before installa on Refer to “Install or Replace the Ba eries” sec on on page 26 for the installa on of ba eries for...
  • Page 10 Skip to page 1 for monitoring contact closure type devices/equipment These Tools may be Required Hammer Phillips Screwdriver Nail (4) Double-sided Moun ng Tape (2) Reed Switch and Magnet Installa on U s e s c r e w s ( y o u c a n a l s o u s e n a i l s o r d o u b l e - s i d e d m o u n n g t a p e i n s t e a d ) t o m o u n t t h e r e e d s w i t c h a n d m a g n e t t o t h e d i ffe r e n t s i d e s o f a d o o r o r w i n d o w o r g a t e ( p l a c e t h e r e e d s w i t c h t o t h e fi...
  • Page 11 Contact Sensor Installa on Methods Method A: Place anywhere Method B: Wall-moun ng the sensor Clean the installa on area Re m ove o n e s i d e o f t h e p ro te c ve l aye r f ro m t h e d o u b l e - s i d e d ta p e , s c k t h e d o u b l e - s i d e d ta p e o n t h e b a c k o f t h e co nta c t s e n s o r R e m o v e t h e o t h e r s i d e o f t h e p r o t e c v e l a y e r f r o m t h e d o u b l e - s i d e d t a p e o n t h e b a c k o f t h e c o n t a c t s e n s o r, p l a c e t h e c o n t a c t s e n s o r i n t h e d e s i r e d p o s i o n , a n d p r e s s fi...
  • Page 12 Contact Closure Device/Equipment Installa on These Tools may be Required Scissors U lity Knife Wire Cu er/Stripper Phillips screwdriver Extra small straight Wire Nuts Electrical Tape screwdriver /Connectors (2) Note Your contact closure type device must be func onal and de-energized/disconnected from other equipment (see page 2 for addi onal informa on on compa ble contacts) Install the sensor ba eries a er installa on Wire nuts (twist-on connectors) are the recommended wire splicing method.
  • Page 13 Get Ready If your device has screw type terminals for wiring connec ons, proceed to the next page. Otherwise, using a wire stripper, remove the insula on on each conductor of alarm contact of the contact closure output device, leaving roughly half an inch of exposed conductor Begin Installa on U s e a w i r e c u e r t o o l t o r e m o v e t h e r e e d s w i t c h f r o m t h e c o n n e c t o r c a b l e ( t a ke g o o d c a r e o f t h e r e e d s w i t c h a n d m a g n e t - s t o r e f o r f u t u r e u s e , a s n e e d e d )
  • Page 14 Te st t h e co nta c t s e n s o r by c h a n g i n g t h e Alarm open/closed state of the monitored door, Contact window or device/equipment. Use the YoLink app to observe the status of the contact sensor (Open or Closed)
  • Page 15: Using The Yolink App

    Using the YoLink App Device page Details * Tap to go to Details page (refer to page 14) Connec on status Device name of sensor and Hub * Edit name on Details page Current Ba ery level * Shown red if replacement is required...
  • Page 16 24) to you when the door/window is le * Tap to delete the device from your YoLink account open for a set me * Default is set to 20 seconds Device status * A er changing “Open Remind” se ngs, press the device’s SET bu on once, to sync Opened or closed the new se ngs to the device.
  • Page 17 Device Alerts Upon the opening or closing or le open for a set me of the door/gate/window/contact closure output device, an alert will be sent to your YoLink account Door is opened Door is closed Door is s ll open (for a set me)
  • Page 18 Automa on Easily set up rules for “if this then do that” func ons Go to “Smart”, tap “Automa on” followed by the “ ” icon to add an automa on Fill in details followed by the “ ” icon * Contact Sensor can be set as a trigger only Tap to add an Tap to save the se ngs...
  • Page 19 Voice Assistants Connect YoLink with third-party voice assistants service to monitor the status of your devices through voice commands Tap “ ” in the upper le corner to go to My Profile Go to Se ngs > Voice Assistants for the applicable voice assistant integra on guide * Contact Sensor is integrated with Alexa and Google Assistant, and is also integrated with IFTTT.com, works as trigger event pipelines using...
  • Page 20: About Yolink Control

    Hub or an internet connec on. (Use of YoLink Control is op onal; you can use the Automa on feature in the app OR use YoLink Control, but YoLink Control offers the benefit of opera on without the Hub or internet connec on.) One device controls another, directly.
  • Page 21 If you want to turn on or off the YoLink Plug Mini when the door is closed, first ensure the door/gate/window is in the closed posi on, or the connected contacts are in the closed...
  • Page 22 * Open the door/gate Turn on the plug /window first * verify the Status LED of YoLink Plug Mini displays blue. Refer to the YoLink Plug Mini manual for more informa on: YS6604-UC_YoLink Plug Mini SET Bu on POWER Bu on...
  • Page 23 Opera on When the door is opened, the YoLink Plug Mini will now immediately turn on. The plug will remain turned on un l turned off using the POWER bu on or via the app More advanced sequences, controlling mul ple outputs (e.g. turn off plug and ac vate siren) are available via the YoLink app Turned off...
  • Page 24 LED quickly blinks blue, then red Upon un-pairing, the Contact Sensor LED will stop blinking and turn off, and the YoLink Plug Mini LED will stop blinking and return to the previous color (blue for turned on, red for turned off)
  • Page 25 SET Bu on or turned off POWER Bu on Hold the SET button for 10-15 Hold the POWER button on the YoLink seconds, until the red light Plug Mini for 10-15 seconds, until the blinks quickly red light blinks quickly...
  • Page 26: Maintenance

    Maintenance Firmware Update To ensure our customers have the best user experience, we highly recommend you update to the newest version firmware when an update is available In “Firmware”, if a new version is listed as available (#### ready now), click it to start the firmware update process The device's firmware will be updated automa cally within 4 hours (maximum).
  • Page 27 Factory reset will erase all of your se ngs and restore it to factory defaults. A er the factory reset, your device will remain in your Yolink account Hold the SET bu on for 20-25 seconds un l the status light blinks red and green alternately,...
  • Page 28 Install or Replace the Ba eries With a li ing/prying ac on on the two clamp latches, open the cover on the sensor (due to the waterproof design, this step may be slightly difficult) Install two new alkaline non-rechargeable AA ba eries , and then close the two clamps of the sensor...
  • Page 29: Specifica Ons

    Specifica ons Voltage: 3V DC (2 - Alkaline Non-Rechargeable AA Ba er ies) Magnet Gap: ≤ 0.7 inch (18 millimeters) Reed Switch Type: NC (Normal closed type) IP63 (Waterproof) IP Ra ng: Environment: Temperature: -4°F - 122°F (-20 °C - 50°C) (Indoor/Outdoor use) Humidity: <...
  • Page 30 Dimensions: 1.97 (50.0) 0.95 (24.1) 0.89 (22.6) 1.42 (36.0) Length of Connec on Cable: Roughly 13 inches (33 cen meters) FRONT SIDE 0.75 0.75 (19.0) (19.0) 1.97 (50.0) 1.42 (36.0) 0.75 (19.0) 0.12 (3.0) 0.28 (7.0)
  • Page 31: Troubleshoo

    Troubleshoo ng Hardware: Ba eries: Ba eries should be brand new, name brand “AA” alkaline type. Refer to “Warnings” Sec on on page 30 Func on: 1. Device is offline - If sensor is not connected to the cloud, press the SET bu on on contact sensor once - If Hub is offline, reconnect the Hub to the Internet and press the SET bu on on contact sensor once - If Hub is not on, power on the Hub again and press the SET bu on on contact sensor once...
  • Page 32: Warning

    Warning Please install, operate and maintain the Contact Sensor only as outlined in this manual. Improper use may damage the unit and/or void the warranty Do not install or use the sensor outside of the temperature and humidity range listed in the Environmental sec on in Specifica ons, on page Lithium non-rechargeable ba eries, opera ng in a wider temperature range , are recommended for applica ons on the ho er...
  • Page 33 Do not use zinc blend ba eries Do not mix new and old ba eries Do not puncture or damage ba eries. Leakage can cause harm on skin contact, and is toxic if ingested Do not dispose of ba eries in fire as they may explode! Please follow local ba ery disposal procedures To avoid damaging the controller, if storing the sensor for an extended period, remove the ba eries...
  • Page 34: Customer Service & Warranty

    This warranty only covers the cost of replacement parts or replacement units, it does not cover shipping & handling fees To implement this warranty please give us a call during business hours at 1-949-825-5958, or visit www.yolink.net Copyright 2020. YoSmart, Inc. All rights reserved...
  • Page 35 FCC statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protec on against harmful interference in a residen al installa on. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruc ons, may cause harmful interference to radio communica ons.
  • Page 36 Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifica ons to this equipment. Such modifica ons could void the user’s authority to operate the equipment. FCC RF radia on exposure statement This equipment complies with FCC RF radia on exposure limits set forth for an uncontrolled environment.

Table of Contents