Asko W2084X/1 Instructions For Use Manual page 10

Table of Contents

Advertisement

Ventilation Requirements of ASKO laundry
concept or closet installation
ASKO's front panel controls make it possible to
install the washers and dryers in a cabinet or closet.
Make sure there is clearance between appliances
and cabinet or wall and 25 mm minimum clearance
between the rear edge of the appliance top panel
and the cabinet or wall.
When closet or cabinet is closed by the door, we
recommend louvered doors, to ensure proper
ventilation.
Otherwise there must be ventilation openings on
the door. See illustration of dimension for ventilation
openings below:
Ensure the dryer door can be opened without
hindrance after installation.
The cool air intake panel at the front of the dryer
must not be blocked or covered. Doing so could
cause a fault.
Disregarding of instructions infl uences on
appliance performance and may also result in failure
of the appliance.
10
ADJUSTING THE FEET
Place the washing machine so that it is stable.
1. Level the washing machine in longitudinal and
traverse direction by rotating the adjustable feet
(using a No. 32 spanner).
The feet allow levelling by +/- 1 cm.
2. When the appropriate height of feet is set, use the
wrench No. 17 to fi rmly fasten the counter-nuts
towards the bottom of the appliance
3. Tighten the jam nuts (counter nuts) to the end
position.
This will reduce washing machine noise, vibration,
movement etc. to minimum.
.