Table of contents Important safety instructions Use of the equipment Introduction Installation Connection Programming Starting up IN1 and IN2 connections Programming transmitter to receiver Programming of one safety transmitter (IN1 input) Programming of two safety transmitters (IN1 and IN2 input) Check the correct operation Maintenance Leds and beeps indication table...
Important safety instructions Disconnect the power supply whenever you proceed to the installation or repair of the equipment. In compliance with the European Low Voltage Directive, we inform you of the fol- lowing requirements: •When the devices remain permanently connected, an easily accessible connecting device must be incorporated into the wiring.
Introduction The RadioBand system is designed of domestic, commercial and industrial door applications where a safety edge is used. The system provides a wireless system replacing spiral cables or energy chain systems to provide the safety signal to the door or gate control panel. The receiver monitors the status of transmitters con- nected to it.
Connection IN1 Connection SW1:1 SW1:2 JCM Optical safety edge (OSE-S7502B and OSE- S7502) Standard optical safety edge 8k2 resistive safety edge NC contact* IN2 Connection SW1:3 NC contact* 8k2 resistive safety edge * In order to comply with the EN 12453:2017 safety standard, NC contact input can not be used to connect safety devices.
Programming Starting up IN1 and IN2 connections See Table IN1 CONNECTION. * These two configurations are supported only if working in WORK mode in the receiver. In programming mode, the receiver will warn us that it cannot support these con- figurations, emitting 6 continuous beeps and leaving programming mode.
Programming of one safety transmitter (IN1 input) Configuration of transmitter programming Mode in the receiver. Led R1 Led R2 Safety edge activates relay 1 on the receiver Safety edge activates relay 2 on the receiver Safety edge activates the two relays 1 and 2 at the same time Programming of two safety transmitters (IN1 and IN2 input) Safety edge in IN1 activates relay 1 and...
Maintenance Leds and beeps indication table The status of leds is shown during 5 minutes after pressing PROG button or dur- ing the Check function. The rest of the time they are turned off. IN1/IN2 Beeps Equipment Message Solution Safety edge activ- beeps transmitter ated...
Replacing the transmitter battery Remove the box cover. Replace the two used batteries with new ones, taking into account the polarity indicated by the connector. Check that the new batteries sup- port the same temperature range as those they are replacing. Before throwing away the device, the batteries must be removed and deposited in a collection point.
Technical data Parameter Value Multifrequency system 868 MHz auto- Frequency adjustable Operating consumption 12mA Radiated power < 25mW Minimum / Maximum 0,20m / 50m range (in open field) 1,5 Years (standard use with optical safety Battery life (aprox) edge: 4 manoeuvres of 30s a day) Reaction time (typical) 35ms Maximum reaction time...
Regulatory Data EU Declaration of conformity JCM TECHNOLOGIES, S.A. hereby declares that the product RB3 TGLA868 com- plies with the relevant fundamental requirements of the RED Directive 2014/53/EU, as well as with the Machine Directive 2006/42/EC whenever its usage is foreseen;...