5-7. Shipping setting
(1)[Procedure]
Holding down the [AV INPUT] key and [MENU] key, turn on the main power, and simultaneously press the (inspection
process) [SELECT A] key and [VOL+] key to change the mode to the adjustment mode.
AV1
SETTING COMPLETE
(2)[Indication]
AV1 is indicated as SETTING COMPLETE.
(3)[Description]
Mode is memorized as SETTING COMPLETE.
Menu setting descriptions are as follows.
VOLUME
30
CONTRAST
30 (AV1 / AV2 / COMPONENT)
TINT
0 (AV1 / AV2 / COMPONENT) (ONLY NTSC)
COLOUR
0 (AV1 / AV2 / COMPONENT)
SHARPNESS
0 (AV1 / AV2 / COMPONENT)
RED
0 (AV1 / AV2 / COMPONENT)
BLUE
0 (AV1 / AV2 / COMPONENT)
COLOUR SYSTEM
AUTO (AV1 / AV2 / COMPONENT)
TREBLE
0
BASS
0
BALANCE
0
BRIGHTNESS
BRIGHT
UPSIDE
NORMAL
RIGHT / LEFT
NORMAL
AV2 IN / OUT
IN