6. REC/PB
Settings :
Method :
of the 10kHz signal is +0.5dB+0.5dB
with
respect
to that of the 1kHz
signal.
Sensitivity Adjustment
*Test
tape: TTA-601
(TTA — 600)
*Test point: TP CONN
7P (PIN301) ©,@
*Input
signal : 400Hz
(LINE
IN)
+ Adjustment
location:
SFR301
(Lch)
SFR302
(Rch)
Apply a 400Hz signal and REC mode. Then
adjust OSC
attenuator
so that the output
level at the TP CONN
7P (PIN301) ©,®©
is 28mV.
Record and play back the 400Hz signal and
adjust SFRs so that the output
is 28mV
+ 0.5dB.
PRACTICAL
SERVICE
FIGURE (DECK)
DECK
SECTION
Tape speed :
Wow & flutter :
Take-up
torque:
3000Hz + 1.5%
Less than 0.4% (R.M.S)
30~55g-cm
(FWD, REV)
F.F torque:
75~170g- cm
Rew
torque :
75~170g- cm
Back
tension :
2~5g-cm
PB Output
level:
280mV + 20mV
(CONN
7P)
REC/PB
Output
level : 280mV + 2dB (CONN
7P)
Distortion
Noise level (PB) :
(REC/PB):
Less than 3% (CrO,)
Less than 3% (NORMAL)
Less than 1.0mV/1.4mV
(DOLBY
B NR
ON/OFF
CrO2)
7. Bias OSC
Frequency
Adjustment
Settings : *« Test
tape : TTA-601
*Test
point :
TP BIAS CHECK
(C403)
Adjustment
location : L401
Method:
Set to the REC mode. Adjust L401 so that
the frequency
counter
of the
test point
reads
106kHz + 2kHz.
Less than
13mV/1.8mV
(DOLBY
C NR
ON/OFF
NORM)
Noise
level
(REC//PB)
:
Erasing
ratio:
REC
bias frequency :
Test
tape:
57
Less than 1.2mV/1imV
(DOLBY
B NR
ON/OFF
CrOz)
Less than
1.3mV/2.imV
(DOLBY
B NR
ON/OFF)
MORM)
More than 60dB
(15Fiz)
106kHz
NORMAL
TTA — 601/600
CrO,
TTA — 610
METAL
TTA-—630